
【国外标准】 Standard Practice for Using the Disposable En Core Sampler for Sampling and Storing Soil for Volatile Organic Analysis (Withdrawn 2018)
本网站 发布时间:
2024-02-28
- ASTM D6418-09
- Withdrawn, No replacement
- 定价: 0元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
This practice is for use in collecting and storing 5- or 25-g soil samples for volatile organic analysis in a manner that minimizes loss of contaminants due to volatilization, or biodegradation, or both. The En Core sampler serves as both the sampling device and sample storage chamber.In performing the practice, the integrity of the soil sample structure is maintained during sample collection, storage, and transfer in the laboratory for analysis or preservation.During sample collection, storage, and transfer, there is very limited exposure of the sample to the atmosphere.Laboratory subsampling is not required when performing this practice. The sample is expelled directly from the coring body/storage chamber into the appropriate container for analysis or preservation without disrupting the integrity of the sample. Subsampling from the En Core device should not be performed to obtain smaller sample sizes for analysis.This practice specifies sample storage in the En Core sampler at 4 ± 2°C for up to 48 h; at –7 to –21°C for up to 14 days; or at 4 ± 2°C for up to 48 h followed by storage at –7 to –21°C for up to five days (see Appendix X1 and reports referenced in footnotes 4, 5, and 6 for information on the performance of the En Core sampler under these storage conditions). , , Storage of samples in the En Core sampler at 4 ± 2°C or –7 to –21°C for longer holding times than those listed above is an option, provided it can be shown that the longer storage time used does not influence the concentrations of the VOCs of interest in the samples, or that the data generated by analysis of the samples meet the DQOs (see Practice D 5792).This practice does not use methanol preservation or other chemical preservatives in the field. As a result, there are no problems associated with flammability hazards, shipping restrictions, or dilution of samples containing low volatile concentrations due to solvents being added to samples in the field.The En Core sampler is a single-use device. It should not be cleaned, or reused, or both.This practice cannot be used for sampling cemented material, consolidated material, or material having fragments coarse enough to interfere with proper coring techniques.FIG. 1 Components of the En Core SamplerFIG. 2 Reusable Attachments to the En Core Sampler1.1 This practice is intended for application to soils that may contain volatile waste constituents.1.2 This practice provides a procedure for using the disposable En Core sampler to collect and store a soil sample for volatile organic analysis.1.3 It is recommended that this standard be used in conjunction with Guide D 4547 and Guide D 4687.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.Note 1—ASTM takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility.
标准号:
ASTM D6418-09
标准名称:
Standard Practice for Using the Disposable En Core Sampler for Sampling and Storing Soil for Volatile Organic Analysis (Withdrawn 2018)
英文名称:
Standard Practice for Using the Disposable En Core Sampler for Sampling and Storing Soil for Volatile Organic Analysis (Withdrawn 2018)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E1815-18(2023) Standard Test Method for Classification of Film Systems for Industrial Radiography
- ASTM E1820-23b Standard Test Method for Measurement of Fracture Toughness
- ASTM E1822-21 Standard Test Method for Fire Testing of Stacked Chairs
- ASTM E1823-23 Standard Terminology Relating to Fatigue and Fracture Testing
- ASTM E1826-23 Standard Specification for Low Volatile Organic Compound (VOC) Corrosion-Inhibiting Adhesive Primer for Aluminum Alloys to Be Adhesively Bonded in Honeycomb Shelter Panels
- ASTM E1827-22 Standard Test Methods for Determining Airtightness of Buildings Using an Orifice Blower Door
- ASTM E1829-14(2020) Standard Guide for Handling Specimens Prior to Surface Analysis
- ASTM E1832-08(2017) Standard Practice for Describing and Specifying a Direct Current Plasma Atomic Emission Spectrometer
- ASTM E1834-18 Standard Test Method for Analysis of Nickel Alloys by Graphite Furnace Atomic Absorption Spectrometry
- ASTM E1835-14(2022) Standard Test Method for Analysis of Nickel Alloys by Flame Atomic Absorption Spectrometry
- ASTM E1845-23 Standard Practice for Calculating Pavement Macrotexture Mean Profile Depth
- ASTM E1851-21 Standard Test Method for Electromagnetic Shielding Effectiveness of Durable Rigid Wall Relocatable Structures
- ASTM E1854-19 Standard Practice for Ensuring Test Consistency in Neutron-Induced Displacement Damage of Electronic Parts
- ASTM E1856-13(2021) Standard Guide for Evaluating Computerized Data Acquisition Systems Used to Acquire Data from Universal Testing Machines
- ASTM E1857-97(2021) Standard Guide for Selection of Cleaning Techniques for Masonry, Concrete, and Stucco Surfaces