【国外标准】 Standard Test Method for Ion Release Evaluation of Medical Implants
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>
标准简介
适用范围:
5.1 Components of implanted medical devices can release ions, which may lead to adverse biological effects if released in sufficient quantities. Therefore, it may be necessary to characterize the ion release behavior over time to verify that a medical device or device components, or both, will not pose an unacceptable risk to patients. Some examples of when time-dependent ion release testing should be considered include:5.1.1 New materials,5.1.2 New applications (for example, different in-vivo environments or new designs) that may degrade corrosion resistance,5.1.3 Manufacturing processes that may lead to increased ion release susceptibility,5.1.4 Results of other corrosion testing (for example, Test Methods F2129 and F3044) indicate high susceptibility to corrosion.5.2 Forming and finishing steps used to create an implantable device may have significant effects on the ion release behavior of the material from which the device is fabricated. Preconditioning can impact the ion release behavior of implants; therefore, prior to testing, devices should be subjected to preconditioning that is appropriate to their application. A justification shall be provided if preconditioning is omitted. Additional information on preconditioning is found in Appendix X1. Substitute test articles (tubes, plates, wires, device subcomponents, etc.) may be used for testing with adequate justification, if all processing steps, including sterilization and preconditioning, are comparable to the finished device.5.3 To accommodate the wide variety of device shapes and sizes likely to be encountered, various sizes and shapes of containers manufactured from various materials can be used. The container material choice should be justified.5.4 Note that the test conditions described in this test method may not completely simulate those encountered in vivo (cells, proteins, mechanical loading, and other specifics of the in-vivo environment); however, the results of this testing conducted in simulated physiological solutions can provide useful data to estimate exposure as part of a risk assessment (for example, as per ISO 10993-17) or to compare different device materials, designs, or manufacturing processes.1.1 This test method assesses metal or other ions released from single-use, metallic, implantable medical devices, or components thereof, by exposing the device to solutions simulating the in-vivo environment and temperature in a container for a predetermined time frame with regular sampling at adequate intervals. Examples of device types that may be evaluated by this test method include, but are not limited to: cardiovascular devices, endovascular devices, and orthopedic implants. Devices which are to be partially implanted, but in long-term contact within the body (such as external fixation devices) may also be evaluated using this method.1.2 This test method is used to assess devices or device components, or both, in their final form and finish, as they would be implanted. For modular implants, consideration should be given to individual testing of every part.1.3 This test method covers the selection of specimens, specimen preparation, test environment, method of exposure, and method for evaluating the results to characterize ion release. Because of the variety of configurations and sizes of implants, a variety of specimen container configurations may be used.1.4 This test method is not intended for ions only adsorbed onto the surface of the samples.1.5 This test method does not apply to absorbable metallic implants (for example, magnesium-based stents, bone screws, etc.) that are intentionally designed to degrade in-vivo.1.6 This test method does not cover the required subsequent chemical analysis, for example, by inductively coupled plasma mass spectrometry (ICP-MS), or the validation of the analytical instrumentation.1.7 This test method does not cover the influence of dynamic loading and associated surface damage or wear on ion release. Ion release may change under dynamic loading conditions and wear. Additional testing may be required, depending on the application and outcome of this test method.1.8 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM F3306-19
标准名称:
Standard Test Method for Ion Release Evaluation of Medical Implants
英文名称:
Standard Test Method for Ion Release Evaluation of Medical Implants标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- 国家标准计划
- 24/30491443 DC standard
- 24/30489392 DC BS EN IEC 62358 Ferrite cores. Standard inductance factor for gapped cores and its tolerance
- BS ISO 19848:2024 - TC Tracked Changes. Ships and marine technology. Standard data for shipboard machinery and equipment
- BS ISO 19848:2024 Ships and marine technology. Standard data for shipboard machinery and equipment
- 24/30487130 DC BS EN 50566:2017/A2:2024 Product standard to demonstrate the compliance of wireless communication
- BS IEC 61360-7:2024 Standard data element types with associated classification scheme
- 24/30486472 DC - Product standard
- KS M ISO 4259-4 석유 및 관련 제품 — 측정 방법과 결과의 정밀도 — 제4부: 개별 실험실에서 표준 시험방법의 실행에 대한 ‘통계적 관리’ 상태를 확인하기 위한 통계적 관리도의 사용
- KS C IEC 61340-4-7 정전기학 — 제4-7부: 구체적 적용 분야에 대한 표준 시험방법 — 이온화
- KS C IEC 61340-4-8 정전기학 — 제4-8부: 구체적 적용 분야에 대한 표준 시험방법 — ESD 차폐성 — 봉투
- KS C IEC 61340-4-6 정전기학 — 제4-6부: 구체적 적용 분야에 대한 표준 시험방법 — 손목접지대
- 24/30485973 DC standard
- BS EN 14662-1:2023 - TC Tracked Changes. Ambient air quality. Standard method for measurement of benzene concentrations
- KS C IEC 61837-2 주파수 제어 및 선택을 위한 표면 실장형 압전 장치 — 표준 아웃라인 및 단자 리드 연결 — 제2부: 세라믹 함체
- 24/30485462 DC BS EN IEC 61753-1 Fibre optic interconnecting devices and passive components - Performance standard