
【国外标准】 Standard Test Method for Furanic Compounds in Electrical Insulating Liquids by High-Performance Liquid Chromatography (HPLC)
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Furanic compounds are generated by the degradation of cellulosic materials used in the solid insulation systems of electrical equipment.5.2 Furanic compounds which are oil soluble to an appreciable degree will migrate into the insulating liquid.5.3 High concentrations or unusual increases in the concentrations of furanic compounds in oil may indicate cellulose degradation from aging or incipient fault conditions. Testing for furanic compounds may be used to complement dissolved gas in oil analysis as performed in accordance with Test Method D3612.1.1 This test method covers the determination in electrical insulating liquids of products of the degradation of cellulosic materials such as paper, pressboard, and cotton materials typically found as insulating materials in electrical equipment. These degradation products are substituted furan derivatives, commonly referred to as furanic compounds or furans. This test method allows either liquid/liquid or solid phase extraction (SPE) of the furanic compounds from the sample matrix followed by analysis for specific furanic compounds by HPLC or direct injection for analysis of specific furanic compounds by HPLC.1.2 The individual furanic compounds that may be identified and quantified include the following:5-hydroxymethyl-2-furaldehydefurfuryl alcohol2-furaldehyde2-acetylfuran5-methyl-2-furaldehyde1.3 The direct injection method generally has a higher limit of detection, especially for furfuryl alcohol. Greater interference for furfuryl alcohol may be expected when using the direct injection method as opposed to extraction methods.1.4 This test method has been used to successfully test for furanic compounds in mineral insulating oil, silicone fluid, high fire point electrical insulating oils of mineral origin, askarels, and perchloroethylene-based dielectric fluids.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D5837-15(2023)
标准名称:
Standard Test Method for Furanic Compounds in Electrical Insulating Liquids by High-Performance Liquid Chromatography (HPLC)
英文名称:
Standard Test Method for Furanic Compounds in Electrical Insulating Liquids by High-Performance Liquid Chromatography (HPLC)标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 其它标准
- 上一篇: ASTM D5836-20 Standard Test Method for Determination of 2,4-Toluene Diisocyanate (2,4-TDI) and 2,6-Toluene Diisocyanate (2,6-TDI) in Workplace Atmospheres (1-2 PP Method)
- 下一篇: ASTM D5839-15(2023) Standard Test Method for Trace Element Analysis of Hazardous Waste Fuel by Energy-Dispersive X-Ray Fluorescence Spectrometry
- 推荐标准
- AS 4276.15:2014 Water microbiology Examination for Vibrio cholerae
- AS 5013.15-2004 Food microbiology Microbiology - General guidance for enumeration of presumptive Escherichia coli - Most probable number technique
- AS IEC 60300.3.15-2011 Dependability management Application guide - Engineering of system dependability
- AS ISO 14520.15-2009 Gaseous fire-extinguishing systems - Physical properties and system design IG-541 extinguishant (ISO 14520-15:2005, MOD)
- AS/NZS 2023:1995 Baths for ablutionary purposes
- AS/NZS 3200.2.15:1994 Approval and test specification - Medical electrical equipment Particular requirements for safety - Capacitor discharge X-ray generators
- AS/NZS 3350.2.15:1997 Safety of household and similar electrical appliances Particular requirements - Appliances for heating liquids
- AS/NZS 3350.2.15:1997/Amdt 1:1997 Safety of household and similar electrical appliances - Particular requirements - Appliances for heating liquids
- AS/NZS 3350.2.15:1997/Amdt 3:2001 Safety of household and similar electrical appliances - Particular requirements - Appliances for heating liquids
- AS/NZS 3350.2.15:1997/Amdt 4:2001 Safety of household and similar electrical appliances - Particular requirements - Appliances for heating liquids
- AS/NZS 3350.2.15:2002/Amdt 1:2003 Safety of household and similar electrical appliances Particular requirements for appliances for heating liquids (IEC 60335-2-15:1995, MOD)
- AS/NZS 3350.2.15:2002/Amdt 2:2003 Safety of household and similar electrical appliances - Particular requirements for appliances for heating liquids (IEC 60335-2-15:1995, MOD)
- AS/NZS 3350.2.15:2002/Amdt 3:2007 Safety of household and similar electrical appliances Particular requirements for appliances for heating liquids (IEC 60335-2-15:1995)
- AS/NZS 3750.15:1998 (R2013) Paints for steel structures Inorganic zinc silicate paint
- AS/NZS 4456.15:1997 Masonry units and segmental pavers - Methods of test Determining lateral modulus of rupture