
【国外标准】 Standard Practice for In-Vitro Environmental Conditioning of Polymer Matrix Composite Materials and Implant Devices (Withdrawn 2017)
本网站 发布时间:
2024-02-28
- ASTM F1634-95(2016)
- Withdrawn, No replacement
- 定价: 0元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 The conditioning procedures covered in this practice provide methods for saturating PMC specimens in a liquid environment prior to conducting other tests for property evaluation.5.2 The conditioning may affect geometric and dimensional changes in specimens. In some severe cases, chemical changes may occur in the fiber, polymer and fiber-polymer interphase and interface.5.3 Caution must be taken if Procedure B (10.2, Procedure B—Accelerated Moisture Saturation at Elevated Temperature) is followed to condition PMC specimens at an elevated temperature. Physical and chemical reactions in materials are normally temperature dependent. An increase in experimental temperature may accelerate a desirable moisture diffusion process. However, elevated temperatures above 37°C may also cause undesirable reactions that do not represent appropriate responses of materials at 37°C. Consequently, a pilot study is recommended in Procedure B to determine if a selected elevated temperature can be used for accelerated conditioning. If the properties of materials are determined to be irreversibly affected by this pilot study at the selected elevated temperature, then either an appropriate lower elevated temperature should be determined by repeating the pilot study, or Procedure B should not be used.1.1 This practice covers two procedures for conditioning non-absorbable polymer matrix composite (PMC) materials and implant devices in a liquid environment to obtain a state of saturation.1.2 The purpose of this practice is to standardize methods and reporting procedures for conditioning PMC materials and implant devices (PMC specimens) in a user selected liquid environment prior to conducting subsequent tests. It is not the purpose of this practice to determine the diffusion coefficients or actual saturation levels of a given liquid into the materials and devices. For these determinations, other procedures, such as Test Method D5229/D5229M, may be followed.1.3 Diffusion of liquid into a solid material is a slow process. While the time necessary to achieve saturation at 37°C may be sufficiently short for thin specimens, such as fracture fixation plates, it may be prohibitively long in thick sections, such as femoral components for hip arthroplasty. However, the diffusion process may be accelerated at an elevated temperature. Consequently, two separate procedures (Procedures A and B) are presented in this practice. Procedure A covers exposing the specimen to the desired conditioning environment at 37°C. Procedure B prescribes a method to accelerate the diffusion process by conditioning the specimen at a selected elevated temperature.1.4 This practice does not specify the test environment to be used for conditioning. However, the pH value of immersion liquid shall be maintained at 7.4 ± 0.2 to simulate the in vivo environment.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM F1634-95(2016)
标准名称:
Standard Practice for In-Vitro Environmental Conditioning of Polymer Matrix Composite Materials and Implant Devices (Withdrawn 2017)
英文名称:
Standard Practice for In-Vitro Environmental Conditioning of Polymer Matrix Composite Materials and Implant Devices (Withdrawn 2017)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E690-15(2020) Standard Practice for In Situ Electromagnetic (Eddy Current) Examination of Nonmagnetic Heat Exchanger Tubes
- ASTM E691-23 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
- ASTM E693-23 Standard Practice for Characterizing Neutron Exposures in Iron and Low Alloy Steels in Terms of Displacements Per Atom (DPA)
- ASTM E695-22 Standard Test Method of Measuring Relative Resistance of Wall, Floor, and Roof Construction to Impact Loading
- ASTM E696-23 Standard Specification for Tungsten-Rhenium Alloy Thermocouple Wire
- ASTM E697-96(2019) Standard Practice for Use of Electron-Capture Detectors in Gas Chromatography
- ASTM E699-16 Standard Specification for Agencies Involved in Testing, Quality Assurance, and Evaluating of Manufactured Building Components
- ASTM E701-80(2018) Standard Test Methods for Municipal Ferrous Scrap
- ASTM E708-79(2017) Standard Specification for Waste Glass as a Raw Material for the Manufacture of Glass Containers
- ASTM E709-21 Standard Guide for Magnetic Particle Testing
- ASTM E715-80(2022) Standard Specification for Gravity-Convection and Forced-Circulation Water Baths
- ASTM E716-16(2021)e2 Standard Practices for Sampling and Sample Preparation of Aluminum and Aluminum Alloys for Determination of Chemical Composition by Spark Atomic Emission Spectrometry
- ASTM E724-21 Standard Guide for Conducting Static Short-Term Chronic Toxicity Tests Starting with Embryos of Four Species of Saltwater Bivalve Molluscs
- ASTM E725-96(2021) Standard Test Method for Sampling Granular Carriers and Granular Pesticides
- ASTM E726-01(2021) Standard Test Method for Particle Size Distribution of Granular Carriers and Granular Pesticides