适用范围:
4.1 The Fricke dosimetry system provides a reliable means for measurement of absorbed dose to water, based on a process of oxidation of ferrous ions to ferric ions in acidic aqueous solution by ionizing radiation (ICRU 80, PIRS-0815, (4)). In situations not requiring traceability to national standards, this system can be used for absolute determination of absorbed dose without calibration, as the radiation chemical yield of ferric ions is well characterized (see Appendix X3).4.2 The dosimeter is an air-saturated solution of ferrous sulfate or ferrous ammonium sulfate that indicates absorbed dose by an increase in optical absorbance at a specified wavelength. A temperature-controlled calibrated spectrophotometer is used to measure the absorbance.1.1 This practice covers the procedures for preparation, testing, and using the acidic aqueous ferrous ammonium sulfate solution dosimetry system to measure absorbed dose to water when exposed to ionizing radiation. The system consists of a dosimeter and appropriate analytical instrumentation. The system will be referred to as the Fricke dosimetry system. The Fricke dosimetry system may be used as either a reference standard dosimetry system or a routine dosimetry system.1.2 This practice is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM Practice 52628 for the Fricke dosimetry system. It is intended to be read in conjunction with ISO/ASTM Practice 52628.1.3 The practice describes the spectrophotometric analysis procedures for the Fricke dosimetry system.1.4 This practice applies only to gamma radiation, X-radiation (bremsstrahlung), and high-energy electrons.1.5 This practice applies provided the following are satisfied:1.5.1 The absorbed dose range shall be from 20 Gy to 400 Gy (1).21.5.2 The absorbed dose rate does not exceed 106 Gy·s−1 (2).1.5.3 For radioisotope gamma sources, the initial photon energy is greater than 0.6 MeV. For X-radiation (bremsstrahlung), the initial energy of the electrons used to produce the photons is equal to or greater than 2 MeV. For electron beams, the initial electron energy is greater than 8 MeV.NOTE 1: The lower energy limits given are appropriate for a cylindrical dosimeter ampoule of 12 mm diameter. Corrections for displacement effects and dose gradient across the ampoule may be required for electron beams (3). The Fricke dosimetry system may be used at lower energies by employing thinner (in the beam direction) dosimeter containers (see ICRU Report 35).1.5.4 The irradiation temperature of the dosimeter should be within the range of 10 °C to 60 °C.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM 51026-23
标准名称:
Standard Practice for Using the Fricke Dosimetry System
英文名称:
Standard Practice for Using the Fricke Dosimetry System标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E866-23 Standard Specification for Corrosion-Inhibiting Adhesive Primer for Aluminum Alloys to Be Adhesively Bonded in Honeycomb Shelter Panels
- ASTM E867-23 Standard Terminology Relating to Vehicle-Pavement Systems
- ASTM E870-82(2019) Standard Test Methods for Analysis of Wood Fuels
- ASTM E871-82(2019) Standard Test Method for Moisture Analysis of Particulate Wood Fuels
- ASTM E872-82(2019) Standard Test Method for Volatile Matter in the Analysis of Particulate Wood Fuels
- ASTM E874-19 Standard Practice for Adhesive Bonding of Aluminum Facings to Nonmetallic Honeycomb Core for Shelter Panels
- ASTM E875-20 Standard Practice for Evaluation of Fungal Control Agents as Preservatives for Aqueous-Based Products Used in the Paper Industry
- ASTM E877-21 Standard Practice for Sampling and Sample Preparation of Iron Ores and Related Materials for Determination of Chemical Composition and Physical Properties
- ASTM E878-20 Standard Test Method for Determination of Titanium in Iron Ores and Related Materials by Diantipyrylmethane Ultraviolet Spectrophotometry
- ASTM E879-20 Standard Specification for Thermistor Sensors for General Purpose and Laboratory Temperature Measurements
- ASTM E88-11(2017) Standard Practice for Sampling Nonferrous Metals and Alloys in Cast Form for Determination of Chemical Composition
- ASTM E882-10(2016)e1 Standard Guide for Accountability and Quality Control in the Chemical Analysis Laboratory
- ASTM E887-21 Standard Test Method for Silica in Refuse-Derived Fuel (RDF) and RDF Ash
- ASTM E889-82(2023) Standard Test Method for Composition or Purity of a Solid Waste Materials Stream
- ASTM E90-23 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements