【国外标准】 Standard Practice for Performance Evaluation of Ambient Outdoor Air Quality Sensors and Sensor-based Instruments for Portable and Fixed-point Measurement
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This practice establishes standardized tests for the performance evaluation of sensor-based continuous instruments for ambient air quality measurements. Public and private air monitoring interests have manifested themselves as a driving force for the deployment of air quality sensors and instruments to quantify air pollutant concentrations in communities, around schools, around industrial facilities, and elsewhere. Users of air quality sensors require information on the performance and limitations of these devices so that informed decisions regarding their suitability for various purposes can be determined. This practice describes both laboratory and field tests that provide information on candidate instrument repeatability, sensitivity, linearity, cross-interferences, drift and comparability with more costly instruments typically used by entities such as government agencies. The air quality sensors are first evaluated in a laboratory chamber by comparing their response to a reference instrument and challenging the gas sensors with interferents. The sensors are then deployed outdoors for field testing at two sites with different climates against reference air quality instruments. This practice is intended to be referenced in standards and codes that establish minimum performance quality for sensor-based ambient outdoor air monitoring.5.2 This practice is intended for air quality sensors that measure one or more of the criteria pollutants in ambient air (ozone, carbon monoxide, nitrogen dioxide, sulfur dioxide, PM10 and PM2.5) that can be operated in outdoor environments and can log a concentration reading. It is not intended for devices or transducers that require additional enclosures for deployment outdoors or post-processing to convert their output signal into a pollutant concentration reading.5.3 It is anticipated that the main users of this practice will be manufacturers, developers, and distributors of outdoor air quality sensors, air quality agencies, and environmental consultants.1.1 This practice establishes standardized tests for the performance evaluation of sensor-based continuous instruments for ambient outdoor air quality measurements. It describes both laboratory and field tests that provide information on candidate sensor repeatability, sensitivity, linearity, cross-interferences, drift, and comparability against reference instruments.1.2 This practice does not apply to sensors or instruments that remotely measure atmospheric pollutants using open path, lidar, or imaging technology.1.3 The evaluation procedures contained in this practice are for sensors that alone or in combination measure outdoor criteria pollutants in ambient air: particulate matter (PM2.5 and PM10), sulfur dioxide (SO2), ozone (O3), carbon monoxide (CO), or nitrogen dioxide (NO2) at concentrations that are relevant to public health.1.4 Testing is to be performed by a competent entity able to demonstrate that it operates in conformity with internationally accepted test laboratory quality standards such as ISO/IEC 17025.1.5 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D8406-22
标准名称:
Standard Practice for Performance Evaluation of Ambient Outdoor Air Quality Sensors and Sensor-based Instruments for Portable and Fixed-point Measurement
英文名称:
Standard Practice for Performance Evaluation of Ambient Outdoor Air Quality Sensors and Sensor-based Instruments for Portable and Fixed-point Measurement标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E3168-20a Standard Practice for Determining Low-Contrast Visual Acuity of Radiographic Interpreters
- ASTM E317-21 Standard Practice for Evaluating Performance Characteristics of Ultrasonic Pulse-Echo Testing Instruments and Systems without the Use of Electronic Measurement Instruments
- ASTM E3170/E3170M-18(2023) Standard Practice for Phased Array Ultrasonic Testing of Polyethylene Electrofusion Joints
- ASTM E3171-21a Standard Test Method for Determination of Total Silver in Textiles by ICP-OES or ICP-MS Analysis
- ASTM E3178-18 Standard Practice for Evaluating Static and Cidal Chemical Decontaminants against Bacillus Spores using Centrifugal Filtration Tubes
- ASTM E3182-20 Standard Practice for Preparing an Occupant Exposure Screening Report (OESR) for Substances in Installed Building Products
- ASTM E3186-19 Standard Guide for Use and Testing of Dry-Block Temperature Calibrators
- ASTM E3191-18 Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination
- ASTM E3192/E3192M-20 Standard Practice for Soft Armor Conditioning by Tumbling
- ASTM E3197-23 Standard Terminology Relating to Examination of Fire Debris
- ASTM E3199-22a Standard Guide for Alternative Allocation Approaches to Modeling Input and Output Flows of Secondary Materials and Related Recycling Scenarios in Life Cycle Assessment
- ASTM E3200-21 Standard Guide for Investment Analysis in Environmentally Sustainable Manufacturing
- ASTM E3208-20 Standard Specification for Minimum Equipment Requirements for Mobile Surface Contaminant Classification and Measurement Equipment
- ASTM E3209/E3209M-20 Standard Test Method for Pavement Thickness by Magnetic Pulse Induction
- ASTM E321-20 Standard Test Method for Atom Percent Fission in Uranium and Plutonium Fuel (Neodymium-148 Method)