
【国外标准】 Standard Guide for Characterization and Assessment of Tissue Engineered Medical Products (TEMPs) for Knee Meniscus Surgical Repair and/or Reconstruction
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Injuries to the knee meniscus are one of the most common orthopaedic problems. Meniscus injures include acute tears (such as occur in sports injuries), chronic degenerative tears, extrusion/subluxation, and/or degenerative dysfunction that occurs as part of the knee aging process or as a result of multiple meniscus surgeries. Knee arthroscopy for partial excision of the knee meniscus (partial meniscectomy) is the most commonly performed orthopaedic procedure.5.2 Complete or near complete excision of the meniscus in a young individual is associated with an early increased risk of knee osteoarthritis due to the loss of the meniscus chondroprotective effects. Lateral meniscal injuries tend to be more severe than medial injuries. Meniscus repair, augmentation, transplantation, and/or reconstruction is recommended in individuals to restore the chondroprotective effect of the meniscus, relieve pain, and prevent degenerative knee osteoarthritis. The potential of TEMPs to enhance the outcome of the surgical meniscus repair and/or reconstruction has been recognized.5.3 The knee joint and temporomandibular joint (TMJ) are examples of joints with meniscal structures.5.4 TEMPS may be used with the intent of enhancing the surgical outcome by improving the biological repair at the site of implantation, by providing mechanical function at a defect site, or by a combination of these mechanisms.5.5 Improving surgical outcome may include improving function relative to the pre-operative condition, shortening the recovery time after surgery, relieving pain, enabling return to normal daily activities, encouraging tissue growth into the defect site, restoring the mechanical function of the meniscus, delaying the progression of osteoarthritis, or any combination thereof.1.1 This guide is intended as a resource for individuals and organizations involved in the production, delivery, and regulation of tissue engineered medical products (TEMPs) and other tissues intended for use in the surgical repair, replacement, and/or reconstruction of the knee meniscus.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM F3223-17
标准名称:
Standard Guide for Characterization and Assessment of Tissue Engineered Medical Products (TEMPs) for Knee Meniscus Surgical Repair and/or Reconstruction
英文名称:
Standard Guide for Characterization and Assessment of Tissue Engineered Medical Products (TEMPs) for Knee Meniscus Surgical Repair and/or Reconstruction标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM D7379/D7379M-08(2021) Standard Test Methods for Strength of Modified Bitumen Sheet Material Laps Using Cold Process Adhesive
- ASTM D7381-07(2021)e1 Standard Practice for Establishing Allowable Stresses for Round Timbers for Piles from Tests of Full-Size Material
- ASTM D7382-20 Standard Test Methods for Determination of Maximum Dry Unit Weight of Granular Soils Using a Vibrating Hammer
- ASTM D7385-21 Standard Guide for Estimating Carbon Saturation by Temperature Rise Upon Immersion
- ASTM D7387-20 Standard Test Method for Vibration Testing of Intermediate Bulk Containers (IBCs) Used for Shipping Liquid Hazardous Materials (Dangerous Goods)
- ASTM D7390-18e1 Standard Guide for Evaluating Asbestos in Dust on Surfaces by Comparison Between Two Environments
- ASTM D7391-20 Standard Test Method for Categorization and Quantification of Airborne Fungal Structures in an Inertial Impaction Sample by Optical Microscopy
- ASTM D7392-20 Standard Practice for PM Detector and Bag Leak Detector Manufacturers to Certify Conformance with Design and Performance Specifications for Cement Plants
- ASTM D7395-18(2023) Standard Test Method for Cone/Plate Viscosity at a 500 s-1 Shear Rate
- ASTM D7396-14(2020) Standard Guide for Preparation of New, Continuous Zinc-Coated (Galvanized) Steel Surfaces for Painting
- ASTM D7398-23 Standard Test Method for Boiling Range Distribution of Fatty Acid Methyl Esters (FAME) in the Boiling Range from 100 °C to 615 °C by Gas Chromatography
- ASTM D7399-18 Standard Test Method for Determination of the Amount of Polypropylene in Polypropylene/Low Density Polyethylene Mixtures Using Infrared Spectrophotometry
- ASTM D7400/D7400M-19 Standard Test Methods for Downhole Seismic Testing
- ASTM D7402-09(2017) Standard Practice for Identifying Cationic Emulsified Asphalts
- ASTM D7403-19 Standard Test Method for Determination of Residue of Emulsified Asphalt by Low Temperature Vacuum Distillation