
【国外标准】 Standard Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
This practice provides guidance in preparing precision and bias statements for ASTM test methods pertaining to construction materials. Test method shall conform to the maximum acceptable range of individual measurements. In order to be valid the indexes of precision to be included in the precision statement as guides for the operator must be based on estimates of the precision of the test method obtained from a statistically designed inter-laboratory series of tests. This series of tests must involve a sufficient number of laboratories, materials, and replicate measurements so that the results obtained provide reliable estimates of the true precision characteristic of the test method. The procedures described in this practice are based on the assumption that the proper estimates of precision have already been obtained. In any test method, tolerances are placed on the accuracy of measuring equipment. All tests made with a given set of equipment which has an error within the permitted tolerance will produce results with a small consistent bias, but that bias is not inherent in the test method and is not included in the bias statement for the test method. There are two conditions which permit the bias of a test method to be estimated: a standard reference sample of known value has been tested by the test method, and the test method has been applied to a sample which has been compounded in such a manner that the true value of the property being measured is known, such as may be the case, for example, in a test for cement content of concrete.1.1 The Form and Style for ASTM Standards requires that all test methods contain statements on precision and bias. Further, the precision statement is required to contain a statement on single-operator precision (repeatability) and a statement on multilaboratory precision (reproducibility). This practice provides guidance for preparing precision and bias statements that comply with these requirements. Discussion of the purpose and significance of precision and bias statements for users of test methods is also provided. Examples of precision statements that conform to this practice are included in Appendix X1. This practice supplements Practice E177 and has been developed to meet the needs of ASTM Committees dealing with construction materials.NOTE 1: Although this practice is under the jurisdiction of Committee C09, the current version was developed jointly by Committees C01 and C09 and has subsequently been adopted for use by other committees dealing with construction materials.1.2 This practice assumes that an interlaboratory study (ILS) has been completed in accordance with Practice C802 or Practice E691. The interlaboratory study provides the necessary statistical values to write the precision and bias statements.1.3 The system of units for this practice is not specified. Dimensional quantities in the practice are presented only in examples of precision and bias statements.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM C670-15
标准名称:
Standard Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials
英文名称:
Standard Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 60745.2.15:2006 Hand-held Motor-operated Electric Tools - Safety Particular requirements for hedge trimmers
- AS/NZS 61000.4.15:2012 Electromagnetic compatibility (EMC) Testing and measurement techniques - Flickermeter - Functional and design specifications
- AS/NZS 61558.2.15:2001 Safety of power transformers, power supply units and similar - Particular requirements for isolating transformers for the supply of medical locations (IEC 61558-2-15:1999, MOD)
- AS/NZS CISPR 15:2011 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment (CISPR 15, Ed.7.2 (2009) MOD)
- ASTM 51026-23 Standard Practice for Using the Fricke Dosimetry System
- ASTM 52303-24 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities
- ASTM A1-00(2018) Standard Specification for Carbon Steel Tee Rails
- ASTM A1000/A1000M-17(2023) Standard Specification for Steel Wire, Carbon and Alloy Specialty Spring Quality
- ASTM A1001-18 Standard Specification for High-Strength Steel Castings in Heavy Sections
- ASTM A1002-16(2020) Standard Specification for Castings, Nickel-Aluminum Ordered Alloy
- ASTM A1004/A1004M-99(2018) Standard Practice for Establishing Conformance to the Minimum Expected Corrosion Characteristics of Metallic, Painted-Metallic, and Nonmetallic-Coated Steel Sheet Intended for Use as Cold Formed Framing Members
- ASTM A1009-18 Standard Specification for Soft Magnetic MnZn Ferrite Core Materials for Transformer and Inductor Applications
- ASTM A101-04(2019) Standard Specification for Ferrochromium
- ASTM A1010/A1010M-13(2018) Standard Specification for Higher-Strength Martensitic Stainless Steel Plate, Sheet, and Strip
- ASTM A1012-10(2021) Standard Specification for Seamless and Welded Ferritic, Austenitic and Duplex Alloy Steel Condenser and Heat Exchanger Tubes With Integral Fins