
【国外标准】 Standard Practice for Low-Flow Purging and Sampling Used for Groundwater Monitoring
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Method Considerations—The objective of most groundwater sampling programs is to obtain samples that are similar in composition to that of the formation water near the well screen. The low-flow purging and sampling method uses the stabilization of indicator parameters to determine when the pump discharge is considered to represent a flow-weighted average of the formation water. Measurements of operational parameters are used to determine potential sampling bias (for example, artifactual turbidity and increased temperature) that may have been introduced by pumping operations and to ensure that the sample is representative of formation water. The low-flow purge rate minimizes lowering of the ambient groundwater level and thereby minimizes potential entrainment of blank-riser pipe (and potentially stagnant) water above or below the screen into the screened-zone of the well. This sampling method assumes that the well has been properly designed and constructed as described in Practices D5092/D5092M and D6725/D6725M, adequately developed as described in Guide D5521/D5521M, and has received proper well maintenance and rehabilitation as described in Guide D5978/D5978M (see Note 1).NOTE 1: This Standard is not intended to replace or supersede any regulatory requirements, standard operating procedure (SOP), quality assurance project plan (QAPP), ground water sampling and analysis plan (GWSAP) or site-specific regulatory permit requirements. The procedures described in this Standard may be used in conjunction with regulatory requirements, SOPs, QAPPs, GWSAPs or permits where allowed by the authority with jurisdiction.5.2 Applicability—Low-flow purging and sampling may be used in a monitoring well that can be pumped at a constant low-flow rate without continuously increasing drawdown in the well (2). If a well cannot be purged without continuously increasing drawdown even at very low pumping rates (for example, 50 – 100 mL/min), the well should not be sampled using this sampling method as described in this standard; a passive sampling method, as described in Guide D7929, may be considered as an alternative.5.3 Target Analytes—Low-flow purging and sampling can be used to collect samples for all categories of aqueous-phase contaminants and naturally-occurring analytes. It is particularly well suited for use where it is desirable to sample aqueous-phase constituents that may sorb or partition to particulate matter, because the method minimizes the potential for artifactual turbidity compared with high flow/high volume purging using a pump, bailer, or inertial-lift device (9-12).1.1 This practice describes the method of low-flow purging and sampling used to collect groundwater samples from wells to assess groundwater quality.1.2 The purpose of this procedure is to collect groundwater samples that represent a flow-weighted average of solute and colloid concentrations transported through the formation near the well screen under ambient conditions. Samples collected using this method can be analyzed for groundwater contaminants and/or naturally occurring analytes.1.3 This practice is generally not suitable for use in wells with very low-yields and cannot be conducted using grab sampling or inertial lift devices. This practice is not suitable for use in wells with non-aqueous phase liquids.1.4 Units—The values stated in SI units are to be regarded as standard. The values given in parentheses are approximate mathematical conversions to inch-pound units that are provided for information only and are not considered standard.1.5 This practice offers a set of instructions for performing one or more specific operations. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this practice may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project's many unique aspects. The word “standard” in the title means only that the document has been approved through the ASTM consensus process.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D6771-21
标准名称:
Standard Practice for Low-Flow Purging and Sampling Used for Groundwater Monitoring
英文名称:
Standard Practice for Low-Flow Purging and Sampling Used for Groundwater Monitoring标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E316-17 Standard Test Method for Determination of Iron in Manganese Ores by Hydrogen Sulfide Reduction-Dichromate Titrimetry
- ASTM E3161-21 Standard Practice for Preparing a Pseudomonas aeruginosa or Staphylococcus aureus Biofilm using the CDC Biofilm Reactor
- ASTM E3163-18 Standard Guide for Selection and Application of Analytical Methods and Procedures Used during Sediment Corrective Action
- ASTM E3164-23 Standard Guide for Contaminated Sediment Site Risk-Based Corrective Action – Baseline, Remedy Implementation and Post-Remedy Monitoring Programs
- ASTM E3166-20e1 Standard Guide for Nondestructive Examination of Metal Additively Manufactured Aerospace Parts After Build
- ASTM E3168-20a Standard Practice for Determining Low-Contrast Visual Acuity of Radiographic Interpreters
- ASTM E317-21 Standard Practice for Evaluating Performance Characteristics of Ultrasonic Pulse-Echo Testing Instruments and Systems without the Use of Electronic Measurement Instruments
- ASTM E3170/E3170M-18(2023) Standard Practice for Phased Array Ultrasonic Testing of Polyethylene Electrofusion Joints
- ASTM E3171-21a Standard Test Method for Determination of Total Silver in Textiles by ICP-OES or ICP-MS Analysis
- ASTM E3178-18 Standard Practice for Evaluating Static and Cidal Chemical Decontaminants against Bacillus Spores using Centrifugal Filtration Tubes
- ASTM E3182-20 Standard Practice for Preparing an Occupant Exposure Screening Report (OESR) for Substances in Installed Building Products
- ASTM E3186-19 Standard Guide for Use and Testing of Dry-Block Temperature Calibrators
- ASTM E3191-18 Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination
- ASTM E3192/E3192M-20 Standard Practice for Soft Armor Conditioning by Tumbling
- ASTM E3197-23 Standard Terminology Relating to Examination of Fire Debris