【国外标准】 Standard Test Method for Total Carbon, Inorganic Carbon, and Organic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This test method is used for determination of the carbon content of water from a variety of natural, domestic, and industrial sources. In its most common form, this test method is used to measure organic carbon as a means of monitoring organic pollutants in high purity and drinking water. These measurements are also used in monitoring waste treatment processes.5.2 The relationship of TOC to other water quality parameters such as chemical oxygen demand (COD) and total oxygen demand (TOD) is described in the literature (6).1.1 This test method covers the determination of total carbon (TC), inorganic carbon (IC), and total organic carbon (TOC) in water in the range from 0.5 to 30 mg/L of carbon. Higher levels may be determined by sample dilution. The test method utilizes ultraviolet-persulfate oxidation of organic carbon, coupled with a CO2 selective membrane to recover the CO2 into deionized water. The change in conductivity of the deionized water is measured and related to carbon concentration in the oxidized sample. Inorganic carbon is determined in a similar manner without the requirement for oxidation. In both cases, the sample is acidified to facilitate CO2 recovery through the membrane. The relationship between the conductivity measurement and carbon concentration is described by a set of chemometric equations for the chemical equilibrium of CO2, HCO3−, H+, and the relationship between the ionic concentrations and the conductivity. The chemometric model includes the temperature dependence of the equilibrium constants and the specific conductances.1.2 This test method has the advantage of a very high sensitivity detector that allows very low detection levels on relatively small volumes of sample. Also, use of two measurement channels allows determination of CO2 in the sample independently of organic carbon. Isolation of the conductivity detector from the sample by the CO2 selective membrane results in a very stable calibration, with minimal interferences.1.3 This test method was used successfully with reagent water spiked with sodium bicarbonate and various organic materials. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.1.4 This test method is applicable only to carbonaceous matter in the sample that can be introduced into the reaction zone. The injector opening size generally limits the maximum size of particles that can be introduced.1.5 In addition to laboratory analyses, this test method may be applied to on line monitoring.1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM D5904-02(2017)
标准名称:
Standard Test Method for Total Carbon, Inorganic Carbon, and Organic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
英文名称:
Standard Test Method for Total Carbon, Inorganic Carbon, and Organic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 4123.7-2006 (R2017)/Amdt 1-2008 Mobile waste containers Colours, markings, and designation requirements
- AS/NZS 1660.2.1:1998 (R2017)/Amdt 1:2001 Test methods for electric cables, cords and conductors - Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods for general application
- AS/NZS 1660.2.4:1998 (R2017)/Amdt 1:2001 Test methods for electric cables, cords and conductors - Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to polyethylene and polypropylene materials
- AS/NZS 1660.2.5:1998 (R2017)/Amdt 1:2001 Test methods for electric cables, cords and conductors - Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to cables above 1 kV
- AS/NZS 3808:2000 (R2017)/Amdt 2:2004 Insulating and sheathing materials for electric cables
- AS/NZS 4488.1:1997 (R2017)/Amdt 1:1999 Industrial rope access systems - Specifications
- AS/NZS 5065:2005 (R2017)/Amdt 1:2010 Polyethylene and polypropylene pipes and fittings for drainage and sewerage applications
- ASTM 51026-23 Standard Practice for Using the Fricke Dosimetry System
- ASTM 51205-24 Standard Practice for Use of a Ceric-Cerous Sulfate Dosimetry System
- ASTM 51275-21e1 Standard Practice for Use of a Radiochromic Film Dosimetry System
- ASTM 51607-22e1 Standard Practice for Use of an Alanine-EPR Dosimetry System
- ASTM 51608-15(2022)e1 Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7.5 MeV
- ASTM 51649-22e1 Standard Practice for Electron Beam Radiation Processing at Energies Between 300 keV and 25 MeV
- ASTM 51818-20e1 Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 80 and 300 keV
- ASTM 51940-22e1 Standard Guidance for Dosimetry for Sterile Insect Release Programs