【国外标准】 Standard Guide for in vitro Axial, Bending, and Torsional Durability Testing of Vascular Stents
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>
标准简介
适用范围:
5.1 It is important to consider the durability of stent designs in deformation modes that are intended to model in vivo conditions. The appropriate amplitude and number of cycles in each of the modes have to be determined independently for the particular clinical use proposed for the stent. These tests do not replicate all varieties and aspects of the deployment process nor the in vivo mechanical environment in its entirety, and as such they cannot be proofs of durability. Instead, the tests provide evidence of durability. The durability tests can also provide a means of assessing design, material or processing changes.5.1.1 This guide might be useful for development testing, specification acceptance testing, and regulatory submission testing and filings as it provides a basic assurance that the tests are designed, executed, and reported in a suitable fashion.5.1.2 If the tests are conducted using a well defined FTF methodology, they can be useful in:5.1.2.1 Potential design improvement through identification of better and worse geometries, materials, and manufacturing processes;5.1.2.2 Understanding product durability by estimating the effects of changes in geometry, materials, or manufacturing processes;5.1.2.3 Estimating the safety factor relative to the amplitudes and other factors in use conditions; and5.1.2.4 Validating finite element analysis (FEA) and fatigue life models.5.1.3 As stated in the scope, this guide is not intended to provide the in vivo physiologic deformation conditions to which a vascular stent can be subjected. Reliable clinical data characterizing cyclic vascular deformation may be lacking for some indications. The user should develop and justify the boundary conditions (e.g., by literature review, in vivo studies, cadaver studies, or modeling of stent vessel interaction) for the chosen durability bench tests. Additional conditions that may be considered include vessel calcification, vessel taper, eccentric lesions, deformation excursions (e.g., exercise), and vessel remodeling.5.1.4 Test methods other than those provided in the annexes of this document might be appropriate, depending upon stent design. However, these methods are beyond the scope of this guide.1.1 This guide includes three separate cyclic deformation durability guides related to vascular stents: bending, axial, and torsional.1.2 This guide does not address flat plate, local crush durability, or multi-mode testing. Although this guide does not address multi-mode testing, the information included herein could be applicable to developing this type of test.1.3 This guide applies to balloon-expandable and self-expanding stents fabricated from metals and metal alloys. It does not specifically address any attributes unique to coated stents (i.e., stents with a surface layer of an additional material(s)), monolithically polymeric stents, or absorbable stents, although the application of this standard to those products is not precluded.1.4 This guide applies to endovascular grafts (“stent-grafts”) and other conduit products commonly used to treat aneurismal disease, peripheral vessel trauma, or to provide vascular access. The information provided herein does not address all issues related to testing of these devices.1.5 This guide is applicable to testing of stent(s) (or a representative portion of a stent). While durability testing of coupon samples (e.g., a scaled-up portion of the stent structure) can provide useful information, it is not within the scope of this guide.1.6 This guide applies to in vitro modeling of stent durability from non-radial arterial motions. Such motions may arise from musculoskeletal activities, including walking and breathing, and cardiac motion. Test Methods F2477 addresses pulsatile (i.e., radial) durability of vascular stents.1.7 This guide does not provide the in vivo physiologic deformation conditions for a vascular stent. It is incumbent upon the user of the standard to develop and justify these boundary conditions (e.g., by literature review, in vivo studies, cadaver studies, or modeling of stent vessel interaction) in these durability bench tests. Additional conditions that may be considered include vessel calcification, vessel taper, eccentric lesions, loading excursions (e.g., exercise), and vessel remodeling.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM F2942-19
标准名称:
Standard Guide for in vitro Axial, Bending, and Torsional Durability Testing of Vascular Stents
英文名称:
Standard Guide for in vitro Axial, Bending, and Torsional Durability Testing of Vascular Stents标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- 国家标准计划
- 24/30491443 DC standard
- 24/30489392 DC BS EN IEC 62358 Ferrite cores. Standard inductance factor for gapped cores and its tolerance
- BS ISO 19848:2024 - TC Tracked Changes. Ships and marine technology. Standard data for shipboard machinery and equipment
- BS ISO 19848:2024 Ships and marine technology. Standard data for shipboard machinery and equipment
- 24/30487130 DC BS EN 50566:2017/A2:2024 Product standard to demonstrate the compliance of wireless communication
- BS IEC 61360-7:2024 Standard data element types with associated classification scheme
- 24/30486472 DC - Product standard
- KS M ISO 4259-4 석유 및 관련 제품 — 측정 방법과 결과의 정밀도 — 제4부: 개별 실험실에서 표준 시험방법의 실행에 대한 ‘통계적 관리’ 상태를 확인하기 위한 통계적 관리도의 사용
- KS C IEC 61340-4-7 정전기학 — 제4-7부: 구체적 적용 분야에 대한 표준 시험방법 — 이온화
- KS C IEC 61340-4-8 정전기학 — 제4-8부: 구체적 적용 분야에 대한 표준 시험방법 — ESD 차폐성 — 봉투
- KS C IEC 61340-4-6 정전기학 — 제4-6부: 구체적 적용 분야에 대한 표준 시험방법 — 손목접지대
- 24/30485973 DC standard
- BS EN 14662-1:2023 - TC Tracked Changes. Ambient air quality. Standard method for measurement of benzene concentrations
- KS C IEC 61837-2 주파수 제어 및 선택을 위한 표면 실장형 압전 장치 — 표준 아웃라인 및 단자 리드 연결 — 제2부: 세라믹 함체
- BS EN IEC 61753-081-02:2023 Fibre optic interconnecting devices and passive components. Performance standard