
【国外标准】 Standard Test Method for Dispersive Characteristics of Clay Soil by Double Hydrometer
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Dispersive clays are those which normally deflocculate when exposed to water of low-salt concentration, the opposite of aggregated clays that would remain flocculated in the same soil-water system (3, 4, 7). Generally, dispersive clays are highly erosive, possibly subject to high shrink-swell potential, may have lower shear strength, and have lower permeability rates than aggregated clays.5.2 When the percent dispersion equals 100, it indicates a completely dispersive clay-size fraction. When the percent dispersion equals 0, it indicates completely nondispersive clay-size fraction.5.3 Available data (1) indicates that the test method has about 85 % reliance in predicting dispersive performance (85 % of dispersive clays show more than 35 % dispersion).5.4 Since this test method may not identify all dispersive clays, design decisions based solely on this test method may not be conservative. It is often run in conjunction with the crumb test (D6572) (4, 7), the pinhole test (D4647/D4647M), or the analysis of the pore water extract (D4542) (4, 7), or combination thereof, to identify possible dispersive clay behavior.NOTE 1: The quality of the result produced by this standard is dependent on the competence of the personal performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depends on many factors; Practice D3740 provides a means of evaluating some of those factors.1.1 This test method provides an indication of the natural dispersive characteristics of clay soils by comparing the amount of particles finer than 2-μm as determined by this method compared to the amount of particles finer than 2-μm as determined by Test Method D7928 (1).2 In order to do this comparison, two similar specimens must be obtained from the sample.1.2 This test method follows the procedure given in Test Method D7928 with the exception that the soil slurry is not mechanically dispersed and no dispersing agent is added.1.3 This test method is applicable only to soils where the position of the plasticity index versus liquid limit plots (Test Methods D4318) falls on or above the “A” line (Practice D2487) and more than 12 % of the soil fraction is finer than 2-μm as determined in accordance with Test Method D7928 (2).1.4 Since this test method may not identify all dispersive clay soils, other tests such as, pinhole dispersion (Test Methods D4647/D4647M), crumb (Test Methods D6572) (3-5) and the analysis of pore water extraction (Test Methods D4542) (4-7) may be performed individually or used together to help verify dispersion.1.5 Units—The values stated in SI units are to be regarded as the standard. Reporting of test results in units other than SI shall not be regarded as nonconformance with this test method.1.6 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026.1.6.1 The procedures used to specify how data are collected/recorded or calculated, in this standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user's objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of this standard to consider significant digits used in analysis methods for engineering design.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D4221-18
标准名称:
Standard Test Method for Dispersive Characteristics of Clay Soil by Double Hydrometer
英文名称:
Standard Test Method for Dispersive Characteristics of Clay Soil by Double Hydrometer标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E747-18 Standard Practice for Design, Manufacture and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for Radiology
- ASTM E749/E749M-17(2021) Standard Practice for Acoustic Emission Monitoring During Continuous Welding
- ASTM E751/E751M-17(2022) Standard Practice for Acoustic Emission Monitoring During Resistance Spot-Welding
- ASTM E756-05(2023) Standard Test Method for Measuring Vibration-Damping Properties of Materials
- ASTM E759/E759M-92(2023) Standard Test Method for Effect of Deflection on Sprayed Fire-Resistive Material Applied to Structural Members
- ASTM E760/E760M-92(2023) Standard Test Method for Effect of Impact on Bonding of Sprayed Fire-Resistive Material Applied to Structural Members
- ASTM E761/E761M-92(2023) Standard Test Method for Compressive Strength of Sprayed Fire-Resistive Material Applied to Structural Members
- ASTM E768-99(2018) Standard Guide for Preparing and Evaluating Specimens for Automatic Inclusion Assessment of Steel
- ASTM E776-23 Standard Test Method for Determination of Forms of Chlorine in Refuse-Derived Fuel
- ASTM E778-15(2021) Standard Test Methods for Nitrogen in Refuse-Derived Fuel Analysis Samples
- ASTM E779-19 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization
- ASTM E780-17(2021) Standard Test Method for Measuring the Insulation Resistance of Mineral-Insulated, Metal-Sheathed Thermocouples and Mineral-Insulated, Metal-Sheathed Cable at Room Temperature
- ASTM E781-86(2023) Standard Practice for Evaluating Absorptive Solar Receiver Materials When Exposed to Conditions Simulating Stagnation in Solar Collectors with Cover Plates
- ASTM E782-95(2022) Standard Practice for Exposure of Cover Materials for Solar Collectors to Natural Weathering Under Conditions Simulating Operational Mode
- ASTM E784-89(2022) Standard Specification for Clamps, Utility, Laboratory, and Holders, Buret and Clamp