【国外标准】 Standard Guide for Analysis of Calibration Data for Nuclear Instruments

本网站 发布时间: 2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!   查看详情>>
标准简介标准简介

适用范围:

5.1 The mathematical and statistical techniques described in this guide support implementation of the calibration requirements of Practice D7282 and the guidance for uncertainty analysis given in Guide D8293. The guidance is intended for use either by qualified specialists at a radioanalytical laboratory or by developers of software for calibration of nuclear instruments.5.2 Applications for single-point calibrations might include:5.2.1 Alpha-particle spectrometry,5.2.2 Gas proportional counters used for thin sources with negligible attenuation, and5.2.3 Gamma-ray spectrometers used for single nuclides.5.3 Applications for calibration curves determined by LLS might include:5.3.1 Mass attenuation curves for gas proportional counters (polynomial), and5.3.2 Quench calibration curves for liquid scintillation counters (polynomial).5.4 Applications for calibration curves determined by NLLS might include:5.4.1 Gamma-ray spectrometry across a range of gamma-ray energies,5.4.2 Mass attenuation curves for gas proportional counters, and5.4.3 Quench calibration curves for liquid scintillation counters.5.5 Although this guide focuses on efficiency calibrations for nuclear instruments, the same general principles and paradigms should apply to other types of calibrations and to other instruments, as long as there are valid uncertainty models for the calibration data.1.1 This guide describes data analysis for efficiency calibrations of nuclear instruments using radioactive sources. It includes the calculation of the calibration parameters, evaluation and use of their uncertainties and covariances, and testing of the calibration data for outliers and overall lack of fit. It also provides guidelines for summarizing and reporting the results of a calibration.1.2 The instrument counting efficiency is assumed to be independent of the radiation emission rate.1.3 Guidance is provided for both single-point calibrations and calibration curves.1.4 The guidance presumes the existence of measurement uncertainty models to provide statistical weighting factors for the calibration data.1.5 This guide does not cover calibrations involving physically-based computer simulations.1.6 The system of units for this guide is not specified. Dimensional quantities in the guide are presented only as illustrations of calculation methods. The examples are not binding on products or test methods treated.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

基本信息

  • 标准号:

    ASTM D8537-23

  • 标准名称:

    Standard Guide for Analysis of Calibration Data for Nuclear Instruments

  • 英文名称:

    Standard Guide for Analysis of Calibration Data for Nuclear Instruments
  • 标准状态:

    Active
  • 发布日期:

  • 实施日期:

  • 出版语种:

标准分类号

  • 标准ICS号:

  • 中标分类号:

关联标准

  • 替代以下标准:

  • 被以下标准替代:

  • 引用标准:

  • 采用标准:

出版信息

  • 页数:

    14 页
  • 字数:

  • 开本:

其他信息

  • 起草人:

  • 起草单位:

  • 归口单位:

    D19.04
  • 提出部门:

  • 发布部门:

  • 推荐标准
  • 国家标准计划