
【国外标准】 Standard Guide for Use of Melt Wire Temperature Monitors for Reactor Vessel Surveillance
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
3.1 Temperature monitors are used in surveillance capsules in accordance with Practice E2215 to estimate the maximum value of the surveillance specimen irradiation temperature. Temperature monitors are needed to give evidence of overheating of surveillance specimens beyond the expected temperature. Because overheating causes a reduction in the amount of neutron radiation damage to the surveillance specimens, this overheating could result in a change in the measured properties of the surveillance specimens that would lead to an unconservative prediction of damage to the reactor vessel material.3.2 The magnitude of the reduction of radiation damage with overheating depends on the composition of the material and time at temperature. Guide E900 provides an accepted method for quantifying the temperature effect. Because the evidence from melt wire monitors gives no indication of the duration of overheating above the expected temperature as indicated by melting of the monitor, the significance of overheating events cannot be quantified on the basis of temperature monitors alone. Indication of overheating does serve to alert the user of the data to further evaluate the irradiation temperature exposure history of the surveillance capsule.3.3 This guide is included in Master Matrix E706 that relates several standards used for irradiation surveillance of light-water reactor vessel materials. It is intended primarily to amplify the requirements of Practice E185 in the design of temperature monitors for the surveillance program. It may also be used in conjunction with Practice E2215 to evaluate the post-irradiation test measurements.1.1 This guide describes the application of melt wire temperature monitors and their use for reactor vessel surveillance of light-water power reactors as called for in Practices E185 and E2215.1.2 The purpose of this guide is to recommend the selection and use of the common melt wire technique where the correspondence between melting temperature and composition of different alloys is used as a passive temperature monitor. Guidelines are provided for the selection and calibration of monitor materials; design, fabrication, and assembly of monitor and container; post-irradiation examinations; interpretation of the results; and estimation of uncertainties.1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. (See Note 1.)1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E1214-11(2023)
标准名称:
Standard Guide for Use of Melt Wire Temperature Monitors for Reactor Vessel Surveillance
英文名称:
Standard Guide for Use of Melt Wire Temperature Monitors for Reactor Vessel Surveillance标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 3894.11-1993 Site testing of protective coatings Equipment report
- AS 5013.11.1-2004 Food microbiology - Microbiology of food and animal feeding stuffs - Preparation of test samples, initial suspension and decimal dilutions for microbiological examination - General rules for the preparation of the initial suspension and decimal dilutions
- AS 5013.11.2-2006 Food microbiology Microbiology of food and animal feeding stuffs - Preparation of test samples, initial suspension and decimal dilutions for microbiological examination - Specific rules for the preparation of meat and meat products
- AS 5013.11.3-2006 Food microbiology Microbiology of food and animal feeding stuffs - Preparation of test samples, initial suspension and decimal dilutions for microbiological examination - Specific rules for the preparation of fish and fishery products
- AS 5013.11.3-2012 Food microbiology Microbiology of food and animal feeding stuffs - Preparation of test samples, initial suspension and decimal dilutions for microbiological examination - Specific rules for the preparation of fish and fishery products (ISO 6887-3:2003, MOD)
- AS 60034.11-2009 Rotating electrical machines Thermal protection
- AS 7240.11-2008 Fire detection and alarm systems Manual call points (ISO 7240-11:2005, MOD)
- AS IEC 60300.3.11-2011 Dependability management Application guide - Reliability centred maintenance
- AS ISO 14520.11-2009 Gaseous fire-extinguishing systems - Physical properties and system design HFC 236fa extinguishant (ISO 14520-11:2005, MOD)
- AS/NZS 1635.11.1:1995 Methods of test for pressure-sensitive adhesive tape - Water vapour transmission rate
- AS/NZS 2023:1995 Baths for ablutionary purposes
- AS/NZS 2891.11:2014 Methods of sampling and testing asphalt Degree of particle coating
- AS/NZS 3200.2.11:1999 Medical electrical equipment Particular requirements for safety - Gamma beam therapy equipment
- AS/NZS 3350.2.11:1995/Amdt 1:1998 Approval and test specification - Safety of household and similar electrical appliances - Particular requirements - Tumbler dryers
- AS/NZS 3350.2.11:1999/Amdt 2:2001 Safety of household and similar electrical appliances - Particular requirements - Tumble dryers