
【国外标准】 Standard Practice for Determining Reporting Conditions and Expected Capacity for Photovoltaic Non-Concentrator Systems
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This practice can be used to determine an expected capacity for an existing or a proposed photovoltaic system in a particular location during a specified period of time (see data collection period in Test Method E2848).5.2 The expected capacity calculated in accordance with this practice can be compared with the capacity measured according to Test Method E2848 when the RC are the same.5.3 The comparison of expected capacity and measured capacity can be used as a criterion for plant acceptance.5.4 The user of this practice must select the performance simulation period over which the reporting conditions and expected capacity will be derived. Seasonal variations will likely cause both of these to change with differing performance simulation periods.5.5 When this practice is used in conjunction with Test Method E2848, the performance simulation period and the data collection period must agree. If they do not agree, the comparison between expected and measured capacity will not be meaningful.5.6 Historical or measured5 plane-of-array irradiance, ambient air temperature, and wind speed data can be used to select reporting conditions and calculate expected capacity. If historical data are used, the data collection period should match the time period of the measured data in terms of season and length.5.7 The simulated power output that is used to calculate the expected capacity should be derived from a performance model designed to represent the photovoltaic system which will be reported per Test Method E2848.1.1 This practice provides procedures for determining the expected capacity of a specific photovoltaic system in a specific geographical location that is in operation under natural sunlight during a specified period of time. The expected capacity is intended for comparison with the measured capacity determined by Test Method E2848.1.2 This practice is intended for use with Test Method E2848 as a procedure to select appropriate reporting conditions (RC), including solar irradiance in the plane of the modules, ambient temperature, and wind speed needed for the photovoltaic system capacity measurement.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E2939-13(2023)
标准名称:
Standard Practice for Determining Reporting Conditions and Expected Capacity for Photovoltaic Non-Concentrator Systems
英文名称:
Standard Practice for Determining Reporting Conditions and Expected Capacity for Photovoltaic Non-Concentrator Systems标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E1415-22 Standard Guide for Conducting Static Toxicity Tests With Lemna gibba G3
- ASTM E1416-23 Standard Practice for Radioscopic Examination of Weldments
- ASTM E1421-99(2021) Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests
- ASTM E1424-22 Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure and Temperature Differences Across the Specimen
- ASTM E1426-14(2019)e1 Standard Test Method for Determining the X-Ray Elastic Constants for Use in the Measurement of Residual Stress Using X-Ray Diffraction Techniques
- ASTM E1432-19 Standard Practice for Defining and Calculating Individual and Group Sensory Thresholds from Forced-Choice Data Sets of Intermediate Size
- ASTM E1439-12(2019) Standard Guide for Conducting the Frog Embryo Teratogenesis Assay-Xenopus (FETAX)
- ASTM E1440-23 Standard Guide for Acute Toxicity Test with the Rotifer Brachionus
- ASTM E1444/E1444M-22a Standard Practice for Magnetic Particle Testing for Aerospace
- ASTM E1448/E1448M-09(2023) Standard Practice for Calibration of Systems Used for Measuring Vehicular Response to Pavement Roughness
- ASTM E1453-20 Standard Guide for Storage of Magnetic Tape Media that Contains Analog or Digital Radioscopic Data
- ASTM E1458-12(2022) Standard Test Method for Calibration Verification of Laser Diffraction Particle Sizing Instruments Using Photomask Reticles
- ASTM E1459-13(2018) Standard Guide for Physical Evidence Labeling and Related Documentation
- ASTM E1461-13(2022) Standard Test Method for Thermal Diffusivity by the Flash Method
- ASTM E1473-22 Standard Test Methods for Chemical Analysis of Nickel, Cobalt, and High-Temperature Alloys