标准详细信息 去购物车结算

【国外标准】 Standard Test Method for Determination of Trace Elements in Biodiesel and Biodiesel Blends by Microwave Plasma Atomic Emission Spectrometry (MP-AES)

本网站 发布时间: 2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!   查看详情>>
标准简介标准简介

适用范围:

5.1 This test method covers the determination of five elements (Ca, Mg, K, Na, and P) in biodiesel and biodiesel blends.5.2 The presence of metals and metalloids in engine fuels can influence the performance of engines and contribute to shortening the lifetime of the equipment. In addition, some elements act as catalyst poison contributing to increases in the amount of unwanted gases and particulate matter emitted by vehicles.1.1 This test method covers the determination of elements in biodiesel and biodiesel blends by microwave plasma atomic emission spectrometry (MP-AES). The specific elements within the scope of this method are calcium (Ca), magnesium (Mg), phosphorus (P), potassium (K), and sodium (Na).1.2 This test method conforms to Practice D6300, subection 8.4.5, valid test result range, and subsection 8.4.6, working range specifications. The valid test result range and working range are recent additions to Practice D6300, and a graphical representation using example values is shown in Appendix X2, Test Method Operating Range.1.3 Method working range:high expected concentration limit = highest ILS sample meanlow expected concentration limit = lowest ILS sample mean if:     lowest ILS sample mean − Rlowest ILS sample mean > 0; otherwise it is     determined by solving for X using the following equation:     X − RX = coarsest resolution, determined by 0.5*σr lowest ILS sample meanBiodiesel and Biodiesel BlendsElement Method Working Range(expected mg/kg)Calcium 0.24 to 15.01Magnesium 0.12 to 11.55Phosphorus 1.69 to 14.24Potassium 0.49 to 13.98Sodium 0.90 to 14.301.4 This test method uses organic elemental standards in organic solvents for calibration and does not purport to quantitatively determine insoluble particulates. Analytical results are particle size dependent, and particles larger than a few micrometers can cause results to appear low.1.5 Elements present at mass fractions above the upper limit of the calibration curves can be determined with additional appropriate dilutions. Elements shall be measured at the wavelengths presented in Table 1. Alternate wavelengths noted in Appendix X1 may be used in the rare case of spectral interference.1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

基本信息

  • 标准号:

    ASTM D8351-22

  • 标准名称:

    Standard Test Method for Determination of Trace Elements in Biodiesel and Biodiesel Blends by Microwave Plasma Atomic Emission Spectrometry (MP-AES)

  • 英文名称:

    Standard Test Method for Determination of Trace Elements in Biodiesel and Biodiesel Blends by Microwave Plasma Atomic Emission Spectrometry (MP-AES)
  • 标准状态:

    Active
  • 发布日期:

  • 实施日期:

  • 出版语种:

标准分类号

  • 标准ICS号:

    75.160.40
  • 中标分类号:

关联标准

  • 替代以下标准:

  • 被以下标准替代:

  • 引用标准:

  • 采用标准:

出版信息

  • 页数:

    9 页
  • 字数:

  • 开本:

其他信息

  • 起草人:

  • 起草单位:

  • 归口单位:

    D02.03
  • 提出部门:

  • 发布部门:

  • 推荐标准
  • 国家标准计划