【国外标准】 Standard Practice for Fan Beam Computed Tomographic (CT) Examination

本网站 发布时间: 2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!   查看详情>>
标准简介标准简介

适用范围:

5.1 This practice establishes the basic parameters for the application and control of fan-beam CT examinations. This practice is written so it can be specified on the engineering drawing, specification, or contract. It will require a detailed procedure delineating the technique or procedure requirements and shall be approved by the Cognizant Engineering Organization (CEO).5.2 The requirements in this practice shall be used when placing a CT system into NDT service and establishing a baseline of system performance measures. Monitoring the system performance over time shall be performed, including calibration procedures, performance measurements, and system maintenance in accordance with Section 9.1.1 This practice establishes the minimum requirements for computed tomography (CT) examination of test objects using fan beam systems (systems that generate one or a few CT cross sectional slices at a time). The examination may be used to nondestructively disclose physical features or anomalies within a test object by providing radiological density and geometric measurements. This practice implicitly assumes the use of penetrating radiation, specifically X-ray and γ-ray.1.2 CT is broadly applicable to any material or test object through which a beam of penetrating radiation passes. The principal advantage of CT is that it provides densitometric (that is, radiological density and geometry) images of thin cross sections through an object without the structural superposition in projection radiography.1.3 There are areas in this practice that may require agreement between the purchaser and the supplier, or specific direction from the cognizant engineering organization. These items should be addressed in the purchase order or the contract. Generally, the items are application specific or performance related, or both.1.4 Techniques and applications employed with CT are diverse. This practice is not intended to be limiting or restrictive. Refer to Guides E1441 and E1672 that provide additional information and guidance on CT fundamentals and tradeoffs in designing or purchasing a CT system, or both.1.5 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

基本信息

  • 标准号:

    ASTM E1570-19

  • 标准名称:

    Standard Practice for Fan Beam Computed Tomographic (CT) Examination

  • 英文名称:

    Standard Practice for Fan Beam Computed Tomographic (CT) Examination
  • 标准状态:

    Active
  • 发布日期:

  • 实施日期:

  • 出版语种:

标准分类号

  • 标准ICS号:

    11.040.50
  • 中标分类号:

关联标准

  • 替代以下标准:

  • 被以下标准替代:

  • 引用标准:

  • 采用标准:

出版信息

  • 页数:

    5 页
  • 字数:

  • 开本:

其他信息

  • 起草人:

  • 起草单位:

  • 归口单位:

    E07.01
  • 提出部门:

  • 发布部门:

  • 推荐标准