【国外标准】 Standard Specification for Joints for Concrete Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
This specification covers joints for precast concrete pipe and box and other sections using preformed flexible joint sealants for use in storm sewers and culverts which are not intended to operate under internal pressure, or are not subject to infiltration or exfiltration limits. Joint material used in horizontal applications is intended to prevent the flow of solids through the joint. The acceptability of the pipe joint and sealant shall be determined by the results of the physical tests prescribed. Bitumen sealants shall be produced from asphalts, hydrocarbon resins and plasticizing compounds reinforced with inert mineral filler and shall contain no solvents. Butyl rubber sealants shall be produced from blends of butyl rubber and refined hydrocarbon resins and plasticizing compounds reinforced with inert mineral filler and shall contain no solvents. The joint design shall consist of a bell or groove on one end of the section and a spigot or tongue on the adjacent end of the joining section. The different test methods for the determination of the composition and physical properties of bitumen or butyl sealants are presented in details. The sections shall be tested hydrostatically in vertical alignment and a sufficient number of sections shall be assembled in straight alignment.1.1 This specification covers joints for precast concrete pipe and box, and other sections using preformed flexible joint sealants for use in storm sewers and culverts which are not intended to operate under internal pressure, or are not subject to infiltration or exfiltration limits. Joint material used in horizontal applications is intended to prevent the flow of solids through the joint.1.2 For precast concrete manhole sections and other vertical structures, which are subject to internal or external pressure, infiltration or exfiltration limits are not prohibited from being specified. Joints in vertical structures covered by this specification are intended mainly to prevent the flow of solids or fluids through the joint.1.3 This specification is to be used with pipe and structures conforming in all respects to Specifications C14, C76, C478, C506, C507, C655, C985, C1433, C1504, and C1577, provided that if there is a conflict in permissible variations in dimensions, the requirements of this specification shall govern.1.4 This specification is the inch-pound companion to C990M; therefore, no SI equivalents are presented in the specification.NOTE 1: This specification covers the material and performance of the joint and sealant only. Infiltration and exfiltration quantities for installed sections are dependent on factors other than the joints which must be covered by other specifications and suitable testing of the installed pipeline.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM C990-09(2019)
标准名称:
Standard Specification for Joints for Concrete Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants
英文名称:
Standard Specification for Joints for Concrete Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ANSI X9.105 Part 3-2009 (R2019) Identical to ISO 8583-3:2008 Financial transaction card originated messages - Interchange message specifications - Part 3: Maintenance procedures for messages, data elements and code values
- ANSI X9.105-1:2009 (R2019) (Identical to ISO 8583-1:2009) Financial transaction card originated messages - Interchange message specifications -Part 1: Messages, data elements and code values
- ANSI X9.8-1-2019/ISO 9564-1-2017 Financial services - Personal Identification Number (PIN) management and security - Part 1: Basic principles and requirements for PINs in card-based systems (Identical Adoption)
- ANSI/OPEI B175.2-2012 (R2019) Outdoor Power Equipment - Internal Combustion Engine-Powered Handheld and Backpack Blowers and Blower-Vacuums - Safety Requirements and Performance Testing Procedures
- ANSI/OPEI B175.7-2019 Outdoor Power Equipment - Internal Combustion Engine-Powered Hand-Held Pole Mounted Pruners - Safety and Environmental Requirements
- AS 1180 (Pt 9A to 9C)-1973 Methods of test for hose made from elastomeric materials - Third Group Methods 9A, 9B, 9C
- AS 1333-1994 (R2019)/Amdt 1-2000 Conveyor belting of elastomeric and steel cord construction
- AS 1678.3C1-1987 Emergency procedure guide - Transport Group text EPGs for Class 3 substances - Flammable liquids - Flammable liquid of lesser hazard
- AS 1684.3 C1 Supp 1-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 1: Timber framing span tables - Wind classification C1 - Seasoned softwood - Stress Grade F5 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 10-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 10: Timber framing span tables - Wind classification C1 - Unseasoned softwood - Stress Grade F5 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 11-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 11: Timber framing span tables - Wind classification C1 - Unseasoned softwood - Stress Grade F7 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 12-2010 Residential timber-framed construction Cyclonic areas - C1 Supplement 12: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F8 (Supplement to AS 1684.3-2010)
- AS 1684.3 C1 Supp 13-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 13: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F11 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 14-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 14: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F14 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 15-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 15: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F17 (Supplement to AS 1684.3-1999)