This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems. These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral. Resilient materials for connectors, filler rings, and mechanical devices shall be tested, and shall conform to the specified values chemical resistance, tensile strength, elongation hardness, accelerated oven-aging, compression set, water absorption, ozone resistance, low-temperature brittle point, and tear resistance. The design of the connector and the pipe stubs are detailed.1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems.1.1.1 These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral.1.2 This specification is the SI companion to C1478.NOTE 1: This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 41 kPa (4.3 m) without leakage when tested in accordance with Section 7. Infiltration quantities for an installed system are dependent upon many factors other than the connections between storm sewer structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.NOTE 2: For installations that exceed 41 kPa (4.3 m), the user is cautioned to verify the amount of hydrostatic head pressure the connector will experience. If the total pressure applied to the connector exceeds the 41 kPa limits of the specification, the user is advised to contact the connector manufacturer for alternative methods of connecting the pipe, or applicable alternative standards.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific warning statement, see 7.2.4.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

This PDF includes GI #2 and #3. 1. Scope 1.1 This Standard applies to plugs, receptacles, and connectors for communication systems intended to electrically terminate (a) communication cords; (b) communication cord sets; or (c) equipment that is c

定价: 455元 / 折扣价: 387

在线阅读 收 藏
ANSI Z21.69-2002/CSA 6.16-2002 Connectors for Movable Gas Appliances 现行 发布日期 :  1970-01-01 实施日期 : 

Scope Details test and examination criteria for gas appliance connectors consisting of flexible tubing for connecting gas supply piping to a gas appliance mounted on casters or otherwise subject to movement. These connectors are limited to a maximum le

定价: 3731元 / 折扣价: 3172

在线阅读 收 藏

Scope Details test and examination criteria for gas appliance connectors consisting of flexible tubing for connecting gas supply piping to a gas appliance mounted on casters or otherwise subject to movement. These connectors are limited to a maximum le

定价: 728元 / 折扣价: 619

在线阅读 收 藏

1.1 Scope 1.1.1 This standard applies to newly produced gas appliance connectors constructed entirely of new, unused parts and materials that: a. Are intended for use with gas-fired commercial cooking equipment that may be mounted on casters or oth

定价: 728元 / 折扣价: 619

在线阅读 收 藏

Scope Details test and examination criteria for gas hose connectors suitable for connecting portable outdoor gas-fired appliances to fixed gas supply lines containing natural, manufactured or mixed gases, liquefied petroleum gases or LP gas-air mixture

定价: 3686元 / 折扣价: 3134

在线阅读 收 藏

1.1 Scope 1.1.1 This standard applies to newly produced outdoor cooking gas appliances (see Part IV, Definitions), constructed entirely of new, unused parts and materials. Outdoor cooking gas appliances submitted for examination under this standard s

定价: 774元 / 折扣价: 658

在线阅读 收 藏

1 Scope This International Standard specifies requirements for the dimensions, basic properties and method of size designation of the most commonly used types of oro-tracheal and naso-tracheal tube made of plastics materials and/or rubber (plain and cu

定价: 865元 / 折扣价: 736

在线阅读 收 藏

Preface This is the fourth edition of CSA C227.3, Low-profile, single-phase, pad-mounted distribution transformers with separable insulated high-voltage connectors. It supersedes the previous editions published in 1991, 1979, and 1974. 1 Scope

定价: 910元 / 折扣价: 774

在线阅读 收 藏

定价: 910元 / 折扣价: 774

在线阅读 收 藏

定价: 3777元 / 折扣价: 3211

在线阅读 收 藏

Details test and examination criteria for connectors suitable for non-rigid connection of outdoor gas appliances not frequently moved after installation, or manufactured (mobile) homes to gas supply lines containing natural, manufactured, mixed and liquef

定价: 728元 / 折扣价: 619

在线阅读 收 藏

定价: 546元 / 折扣价: 465

在线阅读 收 藏