微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

AbstractThese practices cover a data system comprising procedures for the identification of individual chemical substances using infrared absorption spectroscopy and band indexes of spectral data. Although this data system is in use world wide as the largest publicly available data base, it does not represent the optimum way to generate a new data base with the most modern computerized equipment. In addition, the use of these practices requires encoded data and appropriate data handling equipment. The index data, which are available on magnetic tape, include codes for spectral data of chemical substances, chemical-structure classification, empirical formula, melting or boiling point, and serial number reference. Codes on sample state, wavelength intervals of strongest bands, and no-data areas are included as well.1.1 These practices cover a data system generated from 1955 through 1974. It is in world-wide use as the largest publicly available data base. It is recognized that it does not represent the optimum way to generate a new data base with the most modern computerized equipment.1.2 These practices describe procedures for identification of individual chemical substances using infrared absorption spectroscopy and band indexes of spectral data. Use of absorption spectroscopy for qualitative analysis has been described by many (), but the rapid matching of the spectrogram of a sample with a spectral data in the literature by use of a band index system designed for machine sorting was contributed by Kuentzel (). It is on Kuentzel's system that the ASTM indexes of absorption spectral data are based.1.3 Use of these practices requires, in addition to a recording spectrometer and access to published reference spectra, the encoded data and suitable data handling equipment.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏
ASTM E1493-06 Standard Guide for Identification of Bacteriophage M13 or Its DNA (Withdrawn 2014) Withdrawn, No replacement 发布日期 :  1970-01-01 实施日期 : 

This guide is intended for use in a biotechnology laboratory when the need arises to identify a preparation containing M13 bacteriophage or DNA.1.1 This guide covers the identification of bacteriophage M13 used in biotechnology.1.2 There are many variants of M13 that have been developed specifically for cloning technology. These variants have foreign DNA inserted into the M13 genome, causing the M13 to differ in size and genotype.1.3 If the M13 is to be used to construct a recombinant molecule, then the criteria described in Section 6 should be used to characterize the newly made DNA.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

3.1 This specification can be referred to in contract documents as a method and workmanship standard. See also related Specification C542, Specification C716, Terminology C717, and Guide C964.AbstractThis specification covers the packaging, identification and marking, shipment, and storage of lock-strip gaskets, and gasket assemblies and components that are used in building walls.1.1 This specification covers the packaging, identification, shipment, and storage of lock-strip gaskets and components that comply with Specification C542 and that are used in building walls that are not more than 15° from a vertical plane.1.2 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This practice establishes the requirements for physical item identification marking of aluminum and magnesium products. Package marking for shipment and inspection acceptance is not within the scope of this standard. Wrought aluminum and magnesium mill products shall be marked for identification purposes only with the following information on the product or on tags attached to the product: (1) name or registered trademark of the company, (2) alloy and temper of the product, (3) basic number of the specification to which the product was produced, (4) specified (ordered) dimensions of the following products: sheet and plate, coiled wire and spooled wire, straight length tube and coiled tube, and pipe, (5) lot number, and (6) the word "seamless" on certain tube or pipe. Spot marking requirements for the following wrought aluminum and magnesium mill products are detailed and illustrated: (1) coiled sheet, (2) flat sheet and plate, (3) circles, (4) tread plate, (5) foil, (6) rod, bar, and extruded profiles, (7) structural profiles, (8) tube and pipe, (9) wire, (10) bus bar, and (11) forgings such as hand and die forgings. Requirements for marking cast aluminum and magnesium products (castings, remelt ingot for castings, and ingot or billet for fabricating), unalloyed aluminum and magnesium ingot, and special products are specified.1.1 This practice establishes the physical item marking requirements for identification purposes for aluminum and magnesium products. Package marking for shipment and inspection acceptance is not within the scope of this standard.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

4.1 The options available in methods for the measurement of color or color-difference are many. These involve choices in: (1) specimens, (2) geometric and spectral properties of instruments, (3) calibration bases for standards used, (4) procedure for sample handling including conditioning, (5) procedure for taking data, and (6) equations for converting instrumental data to final results. Once the measurements have been made, it is essential to document what has been done for the purpose of interlaboratory comparisons, or for future use. A sample form is provided in Fig. 1 to record identifying information applicable to any instrumental method of color or color-difference measurement.4.2 Refer to Guide E179, Practices E991, E1164, E1345, E1708, E1767, E2152, and E2194 and Test Methods D5386, D6166, E1247, E1331, E1347, E1348, and E1349, for specific details of measurements.1.1 This practice covers the documentation of instrumental measurement of color or color difference for current communication or for future reference. The practice is applicable to instrumental measurements of materials where color is seen by reflected, transmitted or emitted light and any combinations of one or more of these processes. The practice is recommended for documentation of methodology in interlaboratory color-measurement programs.1.2 Providing an adequate identification of an instrumental measure of color or color-difference involves documenting the metadata necessary for archiving and future use of the measurement data collected. The metadata can be divided in five parts:1.2.1 Nature and source of available samples and the form of specimens actually measured,1.2.2 Instrumental conditions of measurement, including instrument geometrical and spectral conditions of measurement,1.2.3 Standards used,1.2.4 Data acquisition procedure, and1.2.5 Color scales employed.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
ASTM E2329-17 Standard Practice for Identification of Seized Drugs Active 发布日期 :  1970-01-01 实施日期 : 

4.1 These are minimum requirements applicable to the identification of seized drugs.4.1.1 As these are minimum requirements, it should be recognized that they may not be sufficient for the identification of all drugs in all circumstances. Within these requirements, it is the responsibility of the individual laboratory’s management to determine which combination of analytical techniques best satisfies the requirements of its jurisdiction.44.2 Correct identification of a drug or chemical depends on the competence of the analyst and the use of an analytical scheme that incorporates validated methods (see Practice E2549). It is expected that in the absence of unforeseen error, an appropriate analytical scheme effectively results in reliable and scientifically supported identifications5 (see Practice E2764).4.3 This practice requires the laboratory’s analytical scheme to incorporate techniques that operate on significantly different principles. It does not discourage the use of any particular method within an analytical scheme. Actual practices followed by a particular laboratory may depend upon jurisdictional requirements.1.1 This practice describes minimum criteria for the qualitative analysis (identification) of seized drugs.1.2 Listed are a number of analytical techniques for the identification of seized drugs. These techniques are grouped on the basis of their discriminating power. Analytical schemes based on these groupings are described.1.3 Additional information is found in Guides E1968, E1969, E2125, and E2548 and Practices E2326, E2327, E2549, and E2764.1.4 This standard should be used in conjunction with sound professional judgment, and cannot replace knowledge, skill, or ability acquired through appropriate education, training, and experience.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 There is no consistent method for the physical placement of an identifying label on equipment in the possession of an entity.5.2 This practice is intended to expedite and improve the physical inventory and self-assessment processes and other occasions in which the instant identification of equipment is needed for purposes of control, management, or determining ownership, or a combination thereof.5.3 The further intent of this practice is to reduce the administrative costs associated with activities requiring equipment identification, that is, physical inventory, self-assessments, and audits and to supplement Practice E2279, Practice E2452, and MIL STD 130.1.1 This practice is for supplemental identification labels assigned by an entity and affixed to equipment to permit control.1.2 Identifying labels include, but are not limited to, removable tags, bands, and plates.1.3 This practice is not intended for material or manufacturer’s warranties.1.4 This practice is not intended for markings of original equipment manufacturers (OEMs).1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

Information Technology - Radio Frequency Identification for Item Management - Part 6: Parameters for Air Interface Communications at 860 MHz to 960 MHz AMENDMENT 1: Extension with Type C and Update of Types A and B

定价: 2184元 / 折扣价: 1857

在线阅读 收 藏
150 条记录,每页 15 条,当前第 2 / 10 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页