微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

3.1 This guide is intended as a reference for those concerned with the inspection of thin- or thick-film coating application to concrete and masonry substrates. It does not cover the application of cement-type coatings. The requirements for inspection should be addressed in all protective coating and lining work specifications. This guide may be used by specification writers when selecting and establishing the inspection requirements for coating and lining specifications. A sample checklist for use by inspectors is included as Appendix X1.1.1.1 This guide is intended as an information aid to painting inspectors in carrying out the task efficiently. It includes the key elements of surface preparation, coatings application, and final approval for both field and shop work. The items should be selected that are pertinent to a specific project.NOTE 1: For additional helpful information, refer to the following documents:Manual of Concrete Practice ACI 515R American Concrete Institute2Manual of Coating Work for Light Water Nuclear Power Plant Primary Containment and Other Safety Related Facilities3C811 Practice for Surface Preparation of Concrete for Application of Chemical-Resistant Resin Monolithic Surfacings4Steel Structures Painting Manual Vol. 1 - Good Painting Practices5Steel Structures Painting Manual Vol. 2 - Systems and Specifications5Manufacturers Specifications and Instructions (made available to the inspector for reference to special requirements for proper application)Safety Data Sheets (needed to ensure that personnel take necessary precautions in handling hazardous materials). Available from Materials manufacturer.1.2 Certain industries or owners may require certified inspection personnel. See Guide D4537 for establishing procedures to certify inspectors for coating work in nuclear facilities. SSPC offers a training and certification program for concrete coating inspection.51.3 In certain cases the inspector may be required to assess the condition of the concrete substrate. SSPC has published an illustrated guide for performing a concrete condition assessment.51.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This guide is arranged in the following order:  SectionReferenced Documents 2  ASTM Standards 2.1  OSHA Standards 2.2  ICRI Standards 2.3  SSPC Standards 2.4 3Preparation for Inspection 4Surface Preparation Methods and Requirements 5  Surface Preparation 5.1  Factors Affecting Coating Performance 5.2  Surface Condition 5.2.1  Cleanliness 5.2.2  Moisture 5.2.3  Surface Preparation Procedures 5.3  Dry Surface Cleaning 5.3.1  Water and Steam Cleaning 5.3.2  Mechanical Tool Cleaning 5.3.3  Hand Tool Cleaning 5.3.3.1  Power Tool Cleaning 5.3.3.2  Scarifying Machines 5.3.3.3  Pre- and Post-Surface Preparation 5.3.3.4  Finished Surface 5.3.3.5  Blast Cleaning 5.3.4  Water Blast Cleaning 5.3.5  Acid Etching 5.3.6Precautions in Preparing Unpainted and   Previously Painted Surfaces 5.4Inspection of Surfaces Prior to Field Painting 5.5  New Construction 5.5.1  Maintenance Repainting 5.5.2Cracks and Voids 6  Cracks 6.1  Cracks in Concrete 6.1.1  Joints in Concrete 6.1.2  Voids 6.2  Recoat Intervals 6.3Coating Storage and Handling 7  Storage of Coating and Thinner 7.1  Mixing of Coatings 7.2  Thinning 7.3  Thinning of Coating 7.3.1  Heating of Coating 7.4Ambient Condition Considerations 8  Drying 8.1  Low Temperature 8.2  High Temperature 8.3  Moisture 8.4  Wind 8.5Coating Application 9  Residual Contaminants 9.1  Quality Assurance 9.2  Film Defects 9.2.1  Brush Application 9.3  Spray Application 9.4  Roller Application 9.5  Miscellaneous Methods 9.6  Rate of Application 9.7  Additional Considerations 10  Ventilation 10.1  Painting Schedule 10.2  Film Integrity 10.3  Recoat Time 10.4  Coating System Failure 10.5Inspection Equipment 11  General 11.1  Adhesion of Existing Coating 11.1.1  Portable Pull-Off Adhesion 11.1.2  Field Inspection Equipment 11.2  Drying and Curing Times 11.2.1  Thermometers 11.2.1.1  Psychrometric Charts 11.2.1.2  Wet-Film Thickness Gages 11.2.2  Interchemical Gage 11.2.2.1  Notched Gage 11.2.2.2  Dry-Film Thickness Gages 11.2.3  Destructive Thickness Gage 11.2.3.1  Nondestructive Film Thickness Gages 11.2.3.2  Discontinuity (Holiday) Tester 11.3Inspection Checklist Appendix X11.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

4.1 Fungi are known to produce objectionable odors, stains, and premature biodeterioration of various consumer products and construction substrates including textiles, carpet, ceiling tile, gypsum wallboard, lumber, and plasticized vinyl and other polymers.4.2 Antifungal activity is typically:4.2.1 Determination of article susceptibility to fungal colonization,4.2.2 Determination of fungistatic activity (qualitative determination of prevented or delayed fungal colonization), and4.2.3 Determination of fungicidal/sporicidal activity (quantitative determination of spore kill).4.3 The degree of required surface examination varies from gross visual examination to detailed microscopic assessment among these methods.4.4 This guide provides an overview of established methods and suggestions for their applicability, with consideration to the type of substrate treated or the type of antifungal treatment being assessed.1.1 This guide provides information on various test methods currently available to assess antifungal activity on natural or synthetic substrates.1.2 Knowledge of microbiological techniques is required for the practice of this guide.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

3.1 Membrane switch keys are subjected to repeated actuations, usually by a human finger. This can transfer body oil, hand creams, automotive fluids and so forth. Materials are often subjected to other conditions (for example, wiping, cleaning, rubbing) during handling, end-use, shipment, or storage that may cause abrasion damage. The result may be a significant removal of the coatings, text, or decorative inks.3.2 This test method is applicable to a wide range of materials. The main criterion is that the abrasion process produces visible wear or breakthrough of the surface being tested.3.3 The amount of abrasion damage to a surface is dependent on numerous variables. This test method provides a way of comparing relative abrasion resistance and the effect of chemicals on inks, coatings, and substrates. In no way do the results provide a correlation value of the number of human finger touches before coating failure. It only provides a means to compare results of tests performed using the same equipment, abrasive materials and loading conditions.3.4 The test method can be used for quality control purposes, as a research and development tool, to evaluate material combinations for a given application, or for the comparison of materials with relatively similar properties and the effect of chemicals on the abrasion resistance.1.1 This test method describes the procedure for subjecting inks or coatings on substrates to an abrasive medium, with or without the application of chemicals, at a specified force.1.2 Within certain limitations, as described in this standard, this test method is applicable for materials including, but not limited to: printed or coated polyester, polycarbonate, and silicone rubber. The samples can be either flat or contoured.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

3.1 The procedure described in this practice is designed to provide a method by which the coating weight of chromium treatments on metal substrates may be determined.3.2 This procedure is applicable for determination of the total coating weight and the chromium coating weight of a chromium-containing treatment.1.1 This practice covers the use of X-ray fluorescence (XRF) techniques for determination of the coating weight of chromium treatments on metal substrates. These techniques are applicable for determination of the coating weight as chromium or total coating weight of a chromium-containing treatment, or both, on a variety of metal substrates.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

1.1 This test method covers the procedure for the performance of calcium phosphate ceramic coatings in shear and bending fatigue modes. In the shear fatigue mode this test method evaluates the adhesive and cohesive properties of the coating on a metallic substrate. In the bending fatigue mode, this test method evaluates both the adhesion of the coating as well as the effects that the coating may have on the substrate material. These test methods are limited to testing in air at ambient temperature. These test methods are not intended for application in fatigue tests of components or devices; however, the test method that most closely replicates the actual loading configuration is preferred. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

4.1 The guide provides recommendations for substrates and methods of surface preparation to be used in comparative tests of building seals and sealants.1.1 This guide describes the recommended standard substrates and their recommended surface preparation for use in standard tests of building seals and sealants.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 This standard is useful for characterizing the wettability of surfaces. A surface that is easy to wet is one over which a coating is more likely to give good adhesion and appearance and less likely to suffer surface tension related defects such as crawling, cratering, pinholing and orange peel.5.2 This standard also can be used to test pigment surfaces for wettability, particularly by potential surfactant- or resin-based dispersants or mill bases. Easily wetted pigments are more likely to be easy to disperse and dispersants/mill bases that wet pigments of interest are more likely to disperse those pigments well.5.3 Although the contact angle is governed by the surface tensions of the test liquid and test surface, the angle cannot provide a surface tension value directly.5.4 A low advancing contact angle value (<45°) is indicative of wetting and angles of 10 to 20° are indicative of excellent wetting.5.5 Water can be used as a test liquid to establish (via the advancing contact angle) whether a surface is hydrophilic (angle <45°), hydrophobic (angle >90°) or somewhere in-between (angle of 45 to 90°). Water contact angles have been used to estimate surface cleanliness before and after cleaning operations, ease of wettability of surfaces by waterborne coatings and the effectiveness of rinsing processes.5.6 An organic liquid such as a solvent also can be used to characterize a substrate, coating or pigment. The resultant contact angle will depend on the surface tensions of the liquid and the test surface. A low surface tension (energy) test surface will not be wet by a high surface tension liquid.5.7 In addition to water and solvents, a surfactant dispersion or dispersant solution can be used to test a pigment surface. Any test liquid that is a potential dispersant for a test pigment must wet the pigment well or it will not work as a dispersant.5.8 Contact angle measurements can be used to map surfaces in terms of hydrophilicity, presence of low surface tension components or contaminants, or variations in composition. Other analytical methods such as infrared microscopy would be needed to identify the chemical moieties that give the contact angle differences.5.9 This test method can be used on nearly all coatings and substrates and may be extended to pigments by compressing the pigment powder into a solid disk.1.1 This practice covers the measurement of the angle of contact when a drop of liquid is applied to a coated surface, substrate, or preformed disk of pigment.1.2 There are two types of contact angles, advancing and receding. This standard deals only with advancing contact angles.1.3 This practice is intended to supplement the manufacturer’s instructions for the device being used to make the measurements, but is not intended to replace them.1.4 A common test liquid is water, but many other liquids such as solvents, surfactant and dispersant solutions and even liquid paints can be used.1.5 This practice is based on goniometry, which involves the observation of a sessile drop of test liquid on a solid substrate.1.6 Although contact angles are governed by surface tension, this standard cannot be used to measure surface tension directly.1.7 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

2.1 All five of the test methods described will produce polish films from emulsion floor polishes which can be used for various performance tests. The choice of test method is left up to the individual laboratory.1.1 These test methods cover procedures for application of emulsion floor polish films to suitable substrates for testing purposes. Five test methods are covered, as outlined in Section 3.1.2 These procedures are limited to use on flat, rigid substrates mounted, if necessary, on a nonabsorbent backing.1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for information only.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 The procedures described in this practice are intended to aid in evaluating the performance of coatings on various metal panels including either new or rusted steel.4.2 The relative durability of paints in outdoor exposures can be very different depending on the location of the exposure because of differences in solar radiation, time of wetness, temperature, pollutants, and other factors. Therefore, it cannot be assumed that results from one exposure in a single location will be useful for determining relative durability in a different location. Exposures in several locations with different climates which represent a broad range of anticipated service conditions are recommended.4.2.1 Because of year-to-year climatological variations, results from a single exposure test cannot be used to predict the absolute rate at which a material degrades. Several years of repeat exposures are needed to get an “average” test result for a given location.4.2.2 Solar radiation varies considerably as function of time of year. This can cause large differences in the apparent rate of degradation in many polymers. Comparing results for materials exposed for short periods (less than one year) is not recommended unless materials are exposed at the same time in the same location.4.3 The in Practice G7 addresses many variables to be considered in exterior exposure tests. Guide G141 provides more information on variability in weathering testing.1.1 This practice covers procedures to be followed for direct exposure of exterior paints and coatings to the environment when applied to metal surfaces. When originators of a weathering test have the actual exposure conducted by a separate agency, the specific conditions for the exposure of test and control specimens should be clearly defined and mutually agreed upon between all parties.1.2 Experience indicates that the metal used as a test substrate has a significant effect upon weathering results. The purpose of this practice is to define specific steel and other metal surfaces to be used for testing in order to minimize this source of variability.1.3 The values stated in SI units are to be regarded as the standard. The values given in parenthesis are for information only.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

1.1 This test method covers the determination of the biaxial flexure strength (modulus of rupture) of thin ceramic substrates. 1.2 This test method is applicable to specimens in the as-fired condition or to test pieces prepared to have a certain thickness or surface finish. 1.3 This test method may be used with specimens of various thicknesses and having warpage; no limits are placed on the latter, except those mutually imposed by the specifications agreed upon between the manufacturer and the purchaser of the substrates. 1.4 The values stated in inch-pound units are to be regarded as the standard. The metric equivalents of inch-pound units may be approximate. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

5.1 Gold coatings are often specified for the contacts of separable electrical connectors and other devices. Electrodeposits are the form of gold that is most used on contacts, although it is also employed as clad metal and as weldments on the contact surface. The intrinsic nobility of gold enables it to resist the formation of insulating oxide films that could interfere with reliable contact operation.5.2 In order that the nobility of gold be assured, porosity, cracks, and other defects in the coating that expose base-metal substrates and underplates must be minimal or absent, except in those cases where it is feasible to use the contacts in structures that shield the surface from the environment or where corrosion inhibiting surface treatments for the deposit are employed. The level of porosity in the coating that may be tolerable depends on the severity of the environment to the underplate or substrate, design factors for the contact device like the force with which it is mated, circuit parameters, and the reliability of contact operation that it is necessary to maintain. Also, when present, the location of pores on the surface is important. If the pores are few in number and are outside of the zone of contact of the mating surfaces, their presence can often be tolerated.5.3 Methods for determining pores on a contact surface are most suitable if they enable their precise location and numbers to be determined. Contact surfaces are often curved or irregular in shape, and testing methods should be suitable for them. In addition, the severity of porosity-determining tests may vary. This test method is regarded as severe.5.4 The relationship of porosity levels revealed by particular tests to contact behavior must be made by the user of these tests through practical experience or by judgement. Thus, absence of porosity in the coating may be a requirement for some applications, while a few pores on the critical surfaces may be acceptable for another. Such acceptance (or pass-fail) criteria should be part of the product specification for the particular product or part requiring the porosity test.5.5 This test method is highly sensitive and is capable of detecting virtually all porosity or other defects in gold coatings that could participate in substrate corrosion reactions. The test is rapid, simple, and inexpensive. In addition, it can be used on contacts having complex geometry such as pin-socket contacts. However, it is preferred that deeply recessed sockets be opened to expose their critical surfaces prior to testing.5.6 This test method is considered destructive in that it reveals the presence of porosity by contaminating the surface with corrosion products and by undercutting the coating at pore sites or at the boundaries of unplated areas. Any parts exposed to these tests shall not be placed in service.5.7 This test method is intended to be used for quantitative descriptions of porosity (such as number of pores per unit area or per contact) only on coatings that have a pore density sufficiently low that the corrosion sites are well separated and can be readily resolved. As a general guideline this can be achieved for pore densities up to about 100/cm2 or per 100 contacts. Above this value the tests are useful for the qualitative detection and comparisons of porosity.1.1 This test method covers equipment and procedures for using nitric acid vapor for determining porosity in gold coatings, greater than 0.6 μm (25 μin.) in thickness, particularly electrodeposits and clad metals used on electrical contacts.1.2 This test method is designed to show whether the porosity level is less or greater than some value that, by experience, is considered by the user to be acceptable for the intended application.1.3 A variety of other porosity testing methods are described in Guide B765 and in the literature.2,3 Other porosity test methods are Test Methods B741, B798, B799, and B809.1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to become familiar with all hazards including those identified in the appropriate Safety Data Sheet (SDS) for this product/material as provided by the manufacturer, to establish appropriate safety, health, and environmental practices, and determine the applicability of regulatory limitations prior to use. Specific precautions are given in Section 8 and 9.4.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

1.1 This test method covers equipment and techniques for determining porosity in gold coatings, particularly electrodeposits and clad metals used on electrical contacts. 1.2 This test method is designed to show whether the porosity level is less or greater than some value which by experience is considered by the user to be acceptable for the intended application. 1.3 This test method is suitable for flat surfaces, or with appropriate fixtures, for gently curved surfaces. 1.4 A variety of other porosity testing methods are described in Guide B765 and in the literature. Detailed critical reviews of porosity testing are also available. Other porosity test methods are B735, B798, B799 and B809. 1.5 This test method is specifically designed for use with gold coatings (>95% gold) on substrates of copper and nickel and their alloys. Although not covered in this standard, variations of this test method may be found useful in evaluating coatings other than gold. 1.6 The values stated in SI units are to be regarded as standard. The values in parenthesis are for information only. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to its use. For a specific precautionary statement, see Note 1.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

4.1 The procedure described in this test method is designed to provide a method by which the coating weight of titanium treatments on metal substrates may be determined.4.2 This test method is applicable for determination of the total coating weight and the titanium coating weight of a titanium-containing treatment.1.1 This test method covers the use of wavelength dispersive X-ray fluorescence (WDXRF) techniques for determination of the coating weight of titanium treatments on metal substrates. These techniques are applicable for determination of the coating weight as titanium or total coating weight of a titanium containing treatment, or both, on a variety of metal substrates.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 Permittivity and dissipation factor are fundamental design parameters for design of microwave circuitry. Permittivity plays a principal role in determining the wavelength and the impedance of transmission lines. Dissipation factor (along with copper losses) influence attenuation and power losses.5.2 This test method is suitable for polymeric materials having permittivity in the order of two to eleven. Such materials are popular in applications of stripline and microstrip configurations used in the 1 GHz to 18 GHz range.5.3 This test method is suitable for design, development, acceptance specifications, and manufacturing quality control.NOTE 2: See Appendix X1 for additional information regarding significance of this test method and the application of the results.1.1 This test method permits the rapid measurement of apparent relative permittivity and loss tangent (dissipation factor) of metal-clad polymer-based circuit substrates in the X-band (8 GHz to 12.4 GHz).1.2 This test method is suitable for testing PTFE (polytetrafluorethylene) impregnated glass cloth or random-oriented fiber mats, glass fiber-reinforced polystyrene, polyphenyleneoxide, irradiated polyethylene, and similar materials having a nominal specimen thickness of 1/16 in. (1.6 mm). The materials listed in the preceding sentence have been used in commercial applications at nominal frequency of 9.6 GHz.NOTE 1: See Appendix X1 for additional information about range of permittivity, thickness other than 1/16 in. (1.6 mm), and tests at frequencies other than 9.6 GHz.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

This specification establishes the requirements for labelling of materials and products (including packaging), wherein a biodegradable plastic film or coating is attached (either through lamination or extrusion directly onto the paper) to compostable substrates and the entire product or package is designed to be composted in municipal and industrial aerobic composting facilities. This specification, however, does not describe the contents of the product or their performance with regards to compostability or biodegradability. In order to compost satisfactorily, the product must demonstrate each of the three characteristics as follows: (1) proper disintegration during composting; (2) adequate level of inherent biodegradation; and (3) no adverse impacts on the ability of composts to support plant growth.1.1 This specification covers end items that include plastics or polymers where plastic film/ sheet or polymers are incorporated (either through lamination, extrusion or mixing) to substrates and the entire end item is designed to be composted under aerobic conditions in municipal and industrial composting facilities, where thermophilic temperatures are achieved.1.2 This specification is intended to establish the requirements for labeling of end items which use plastics or polymers as coatings or binders, as “compostable in aerobic municipal and industrial composting facilities.”1.3 The properties in this specification are those required to determine if end items (including packaging) which use plastics and polymers as coatings or binders will compost satisfactorily, in large scale aerobic municipal or industrial composting where maximum throughput is a high priority and where intermediate stages of plastic biodegradation must not be visible to the end user for aesthetic reasons.1.4 The following safety hazards caveat pertains to the test methods portion of this standard: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.NOTE 1: There is no known ISO equivalent for this standard.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
46 条记录,每页 15 条,当前第 2 / 4 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页