This specification covers crosslinked chlorinated polyethylene compounds intended for use as jacket materials (outer coverings) on electrical wires and cables for general-purpose, heavy-duty, and extra-heavy-duty service. The materials under this specification, however, are not recommended for applications with very low temperature service requirement. Physical tests shall be performed and shall conform to the physical property requirements specified such as tensile strength, tensile stress at elongation, elongation at rupture, and tension set. Per service requirement, additional tests for sunlight and weather resistance shall be performed as well, and shall conform to the tensile strength and elongation requirements specified.1.1 This specification covers crosslinked chlorinated polyethylene (CPE) compounds suitable for use as outer coverings or jackets on electrical cables for general-purpose, heavy-duty, and extra-heavy-duty service.1.2 These jacket materials are not recommended for use on cables which are to be installed at a temperature less than –25 °C.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers the standard requirements for crosslinked chlorosulfonated polyethylene compounds intended for use as jacket materials (outer coverings) on electrical wires and cables for general-purpose, heavy-duty, and extra-heavy-duty service. The materials under this specification, however, are not recommended for applications with very low temperature service requirement. Physical tests shall be performed to assess the conformance of the jacket material with the physical property requirements such as tensile strength, tensile stress at elongation, elongation at rupture, tension set, and tear. Per service requirement, additional tests for sunlight and weather resistance shall be performed as well, and shall conform to the requirements specified.1.1 This specification covers crosslinked chlorosulfonated polyethylene compounds suitable for use as outer coverings or jackets on electrical cables for general-purpose, heavy-duty, and extra-heavy-duty service.1.2 These jacket materials are not recommended for cables installed at a temperature lower than −25°C.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

5.1 Dissipation factor, permittivity, and dc volume resistivity are properties of communication cable fillers and filler components that are controlled in order that the cable's electrical performance falls within its design limits. Relatively small amounts of contaminants, such as polar compounds, water, or salts degrade the cable's electrical properties. Limits on the dielectric properties of the cable filling compound are usually specified by the cable manufacturer, by industry standards or both.1.1 This test method covers the determination of dissipation factor, permittivity (dielectric constant), and ac volume resistivity of wire and cable filling compounds and related materials that are solid at room temperature, but capable of being melted at elevated temperature.1.2 Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

3.1 The selection criteria is to be applied for uses of (1) new cable and (2) replacement cable.3.2 For the selection of new cable or the selection of replacement cable, this practice defines the choice criteria for conductor selection for cables in AWG (ASTM) or metric (IEC) sizes.1.1 This practice is intended as a guide to shipbuilders, shipowners, and design agents for use in the selection of conductor size for single conductor or multiple conductor cable sizes either in American Wire Gauge (AWG) or metric designations for commercial ship design and construction.1.2 The comparison chart of electrical conductor sizes shown in Table 1 presents a combined listing of stranded uncoated (plain) copper conductors in accordance with AWG Class B stranding (Specification B8) inch-pound units or international standard sizes of Class 2 IEC (Specification IEC 60228) metric units.1.3 As a precautionary caveat, some conductor sizes listed in Table 1 may exceed minimal size requirements of the U.S. Coast Guard, the American Bureau of Shipping, and IEEE STD 45 for specific applications.1.4 The values stated for ampacity and dc resistance are presented as maximum values and are provided for information only.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

1.1 This specification covers cable in conduit (CIC), which is a smooth-walled, coilable, high-density polyethylene (HDPE) conduit (duct) that contains preassembled wires and cables. The outside diameter of the conduit is controlled and the wire or cable encased within may be comprised of single or multiple configurations consisting of electrical/power wires or cables, fiber optic, traditional copper communication, coaxial cable, or any combination thereof. CIC configurations are preassembled into the conduit during the extrusion process and in industry-specific designs for use in commercial, industrial, transportation, government, and utility applications1.2 This specification does not attempt to identify every possible preassembled conduit/cable configuration but is intended to identify material and minimum assembled product properties for optimizing reliability and service life.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.NOTE 1: UL 1990 and CSA C22.2 No.327 have a similar scope to D3485; however, there are differences in scope and requirements.NOTE 2: End users may elect to field install single or multiple wire or cable configurations into field-installed conduit. In the case where polyethylene conduit is to have the wire or cable configurations field installed, then the more appropriate specifications to select for establishing the conduit’s material, dimensional, workmanship, and property tests would be Specification F2160, UL 651A, CSA C22.2 No.327 or NEMA TC-7.NOTE 3: Whenever two sets of values are presented, in different units, the imperial units are the standard, while those in the parentheses (metric units) are provided for informational purposes.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This specification covers an ozone-resisting crosslinked rubber insulation compound for electrical wires and cables. The polymer shall consist substantially of ethylene-alkene copolymer (EAM) or ethylene-alkene diene terpolymer (EADM). This polymer type includes ethylenepropylene copolymer (EPM) and ethylenepropylene diene terpolymer (EPDM). The crosslinked insulation shall conform to the requirements for physical properties specified. Tests shall be performed in accordance to the following test methods: AC voltage withstand test; insulation resistance; DC voltage withstand tests; capacitance and dissipation factor; partial discharge level test; accelerated water absorption; and ozone resistance.1.1 This specification covers an ozone-resisting crosslinked rubber insulation compound for electrical wires and cables. The polymer shall consist substantially of ethylene-alkene copolymer (EAM) or ethylene-alkene diene terpolymer (EADM). This polymer type includes ethylenepropylene copolymer (EPM) and ethylenepropylene diene terpolymer (EPDM).1.2 This type of insulation is considered suitable for use on wire or cable which will be used in wet and dry locations with conductor temperatures up to 90°C during continuous operation, to 130°C during emergency overload conditions, and to 250°C during short-circuit conditions. It is considered suitable for all sizes and voltage classifications of single- and multiple-conductor power cables up to 35 000 V phase-to-phase at the 100 % insulation level and up to 25 000 V at the 133 % insulation level as listed in Table 1D of Test Methods D470. Single-conductor cables shall have a supplementary covering over the insulation, and multiple-conductor cables shall have an overall covering.1.3 Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in parentheses are for information only.1.4 In many instances the insulation material cannot be tested unless it has been formed around a conductor or cable. Therefore, tests are done on insulated wire or cable in this specification solely to determine the relevant property of the insulation and not to test the conductor or completed cable.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

This specification covers thermoplastic chlorinated polyethylene (CM) compounds suitable for use as an outer covering or jacket on electrical cables. Thermoplastic jackets shall conform to the requirements for physical properties specified. The sunlight and weather resistance of the jackets shall be tested to meet the requirements specified.1.1 This specification covers thermoplastic chlorinated polyethylene (CPE) compounds suitable for use as an outer covering or jacket on electrical cables.1.2 These jacket materials are suitable for use on cables which will be installed at temperatures above –35 °C.1.3 The values stated in inch-pound units are regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏