微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

1.1 This specification covers aluminum-alloy 5005 Drawing stock, 0.375 in. (9.52 mm) in diameter, in the tempers shown in Table 1, for drawing into wire for electrical conductors (Explanatory Notes 1 and 2). 1.2 The SI values for density and resistivity are regarded as the standard. For all other properties the inch-pound values are to be regarded as standard and the SI units may be approximate. Note 1-The alloy and temper designations conform to ANSI H35.1. Aluminum-alloy 5005 corresponds to unified numbering system alloy A95005 in accordance with Practice E527.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

5.1 This test method is useful for establishing the integrity of composite rod. The presence of voids, cracks, and hollow fibers are considered detrimental to the structural integrity of the composite and causes reduced electrical resistance and increased current leakage.5.2 A perfect composite would be flaw-free, and there would be no possibility of wicking. Composites of this type are virtually nonexistent, as there will typically be entrapped air in the resin developed during manufacturing, occasional hollow fibers, and occasional cracks due to thermal stresses.5.3 This test method is intended to provide a tool for measuring the extent of wicking in a composite over very short lengths of material for comparative purposes. The presence of wicking over 1 in. (2.54 cm) lengths will not necessarily imply that the composite will perform unsatisfactorily for its intended end-use. Therefore, interpretation of test results shall be made carefully.5.4 This test method was developed as a technique for estimating quality and consistency of pultruded rod and bar stock, which is a composite of resin and all-roving reinforcement. This test method will be useful for a manufacturer to determine whether any gross changes in quality have taken place due to process or raw material changes as the manufacturing process also affects the quality of the product.5.5 Since the results of this test are so sensitive to sample size, penetrant type, penetrant used, viscosity, duration of test, and other factors, no attempt to arrive at or recommend development of a specification for these materials has been made. A specification shall be negotiated between supplier and end user and such specification shall be made with great care.1.1 This dye-penetrant test method covers a means of evaluating solid fiberglass all-roving reinforced pultruded rod or bar stock for longitudinal wicking. There are generally three mechanisms that promote wicking such as delaminations, longitudinal continuous voids, or the presence of hollow fibers. Any or all of them will be operating at a given time.NOTE 1: Occasionally the flaws listed above may be detected by this test, but other tests are usually required.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems has the potential to result in nonconformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 10.3 and 10.6.NOTE 2: There is no known ISO equivalent to this test method.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers aluminium 1350 drawing stock for electrical purposes. The stock shall conform to the chemical composition requirements. The stock shall be uniform in quality and temper and shall be suitable for drawing into wire. The tensile strength tests and requirements for the respective tempers of stock are presented in details. The stock shall be furnished in continuous-length coils without joints, unless otherwise agreed upon between the manufacturer and purchaser. The electrical resistivity tests shall be made on full-section samples of the stock.1.1 This specification covers aluminum 1350 drawing stock 0.375 in. (9.52 mm) to 1.000 in. (25.40 mm) in diameter, in the tempers shown in Table 1, for drawing into wire for electrical conductors (Explanatory Note 1 and Note 2).1.2 The SI values of density and resistivity are to be regarded as the standard. For all other properties the inch-pound values are to be regarded as standard and the SI units may be approximate.NOTE 1: Prior to 1975, aluminum 1350 was designated as EC aluminum.NOTE 2: The aluminum and temper designations conform to ANSI H35.1. Aluminum 1350 corresponds to unified numbering system A91350 in accordance with Practice E527.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
18 条记录,每页 15 条,当前第 2 / 2 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页