微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读
ASTM E2356-18 Standard Practice for Comprehensive Building Asbestos Surveys Active 发布日期 :  1970-01-01 实施日期 : 

定价: 918元 / 折扣价: 781 加购物车

在线阅读 收 藏

This specification establishes the requirements for rolled copper sheets and strips in flat lengths or coils of ounce-weight thicknesses for roofing, flashing, gutters, downspouts, and general sheet metal work in building construction. Products produced to this specification are not intended for electrical applications. Materials are available in the following tempers: O60 (soft), H00 (cold-rolled), H01 (cold-rolled, high yield), H02 (half hard), H03 (three-quarter hard), and H04 (hard). Products shall be sampled and prepared, then tested accordingly to examine their conformance to dimensional (mass, thickness, length, width, weight, and straightness), mechanical (tensile and yield strength, and Rockwell hardness), chemical composition, and grain recrystallization requirements.1.1 This specification establishes the requirements for rolled copper sheet and strip in flat lengths or coils in ounce-weight thicknesses for roofing, cladding, flashings, gutters, downspouts, and general sheet metal work for building construction.1.1.1 Products produced to this specification are not intended for electrical applications.1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.NOTE 1: Specification B101 is an associated specification for lead-coated copper sheets and strip for building construction.1.3 The following hazard caveat pertains to the test methods portion, Section 16, of this specification1.3.1 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

4.1 These test methods are intended to evaluate the duration for which the types of building elements noted in 1.1 contain a fire, retain their structural integrity, or exhibit both properties during a predetermined test exposure.4.2 The test exposes a test specimen to a standard fire controlled to achieve specified temperatures throughout a specified time period. When required, the fire exposure is followed by the application of a specified standard fire hose stream applied in accordance with Practice E2226. The test provides a relative measure of the fire-test-response of comparable building elements under these fire exposure conditions. The exposure is not representative of all fire conditions because conditions vary with changes in the amount, nature and distribution of fire loading, ventilation, compartment size and configuration, and heat sink characteristics of the compartment. Variation from the test conditions or test specimen construction, such as size, materials, method of assembly, also affects the fire-test-response. For these reasons, evaluation of the variation is required for application to construction in the field.4.3 The test standard provides for the following:4.3.1 For walls, partitions, and floor or roof test specimens:4.3.1.1 Measurement of the transmission of heat.4.3.1.2 Measurement of the transmission of hot gases through the test specimen.4.3.1.3 For loadbearing elements, measurement of the load carrying ability of the test specimen during the test exposure.4.3.2 For individual loadbearing members such as beams and columns:4.3.2.1 Measurement of the load carrying ability under the test exposure with consideration for the end support conditions (that is, restrained or not restrained).4.4 The test standard does not provide the following:4.4.1 Information as to performance of test specimens constructed with components or lengths other than those tested.4.4.2 Evaluation of the degree by which the test specimen contributes to the fire hazard by generation of smoke, toxic gases, or other products of combustion.4.4.3 Measurement of the degree of control or limitation of the passage of smoke or products of combustion through the test specimen.4.4.4 Simulation of the fire behavior of joints between building elements such as floor-wall or wall-wall, etc., connections.4.4.5 Measurement of flame spread over the surface of test specimens.4.4.6 The effect on fire-resistance of conventional openings in the test specimen, that is, electrical receptacle outlets, plumbing pipe, etc., unless specifically provided for in the construction tested. Also see Test Method E814 for testing of fire stops.1.1 The test methods described in this fire-test-response standard are applicable to assemblies of masonry units and to composite assemblies of structural materials for buildings, including loadbearing and other walls and partitions, columns, girders, beams, slabs, and composite slab and beam assemblies for floors and roofs. They are also applicable to other assemblies and structural units that constitute permanent integral parts of a finished building.1.2 It is the intent that classifications shall register comparative performance to specific fire-test conditions during the period of exposure and shall not be construed as having determined suitability under other conditions or for use after fire exposure.1.3 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions.1.4 These test methods prescribe a standard fire exposure for comparing the test results of building construction assemblies. The results of these tests are one factor in assessing predicted fire performance of building construction and assemblies. Application of these test results to predict the performance of actual building construction requires the evaluation of test conditions.1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.6 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 843元 / 折扣价: 717 加购物车

在线阅读 收 藏

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 843元 / 折扣价: 717 加购物车

在线阅读 收 藏
ASTM C717-24 Standard Terminology of Building Seals and Sealants Active 发布日期 :  1970-01-01 实施日期 : 

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

4.1 This guide is intended to assist the construction team in evaluating the constructability, functionality, sequence of construction, interference, tolerances, component performance, and assembled system performance of the exterior wall systems.4.2 This guide does not establish specific roles for the parties involved during construction or the contractual obligations of those parties. The role of each party within any specific project should be established and documented before the start of the project.4.3 This guide is intended for use when specifying construction mockups that are either integrated mockups or off-structure mockups.4.4 This guide is intended to aid the specifier in the development of a QA mockup program for assessing the performance of exterior walls. It is not intended to provide a comprehensive list of applicable test methods for QA testing available or applicable to a mockup program.4.5 This guide does not address preconstruction laboratory testing of a wall system.4.6 This guide is intended to address technical issues with the performance of the wall system and the interconnection of the various components and systems. A mockup may or may not be used as an aesthetic mockup; however, this guide is not intended to address aesthetic issues with the wall system.4.7 This guide is not intended to provide guidance for construction observation services. However, the mockup may be useful to inform inspectors of the intended construction, sequence, materials, and interface conditions encountered on the project and serve as a standard of quality to which the remainder of construction can be compared.1.1 This guide provides information to assist in the specification, design, and performance testing of field-constructed exterior wall assemblies (“mockups”) for construction projects. This includes testing procedures appropriate to evaluate the component and assembly performance for water penetration resistance, air leakage resistance, and other test methods that may be applied as part of the quality assurance (QA) program for the installed systems.1.2 This guide is intended to be applied to exterior wall mockups that include components, systems, and assemblies including, but not limited to, curtain walls, windows, doors, masonry walls, precast concrete, cast-in-place concrete, exterior insulation and finish system (EIFS), roofing interfaces, stucco, wood siding, metal panels, sealants, appurtenances, penetrations, louvers, and combinations thereof. Such mockups are expected to include the intersection between wall systems.1.3 This guide is not intended to provide a comprehensive list of potential testing that may be applicable to field-constructed mockups. Additional tests may be applicable to mockups for specific projects.1.4 This guide is not intended to address all possible project delivery methods and as such the requirements listed herein must be evaluated by the specifier for appropriateness with the delivery method.1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
224 条记录,每页 15 条,当前第 3 / 15 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页