3.1 Measurement of the thickness of the product may be required for quality control purposes or to ensure compliance with applicable specifications.1.1 This test method covers the determination of thickness of resilient nontextile floor coverings including tile and sheet having flat surfaces. This test method should not be used on materials having a foamed layer.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

3.1 This test method is applicable for wear layers with a minimum thickness of 0.001 in. (0.02 mm) to a maximum thickness of 0.1 in. (2.54 mm), where measurements within 0.0005 in. or 0.01 mm are tolerable.1.1 This test method covers the determination of the thickness of the wear layer of resilient non-textile floor coverings, in tile or sheet form, with or without felt backing or foam layer, by optical measurement.1.2 This test method is applicable for wear layers with a minimum thickness of 0.0004 in. (0.01 mm) to a maximum thickness of 0.1 in. (2.54 mm), where measurements within 0.0001 in. or 0.0025 mm are tolerable.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 This practice provides minimum recommendations for the installation of thick poured gypsum concrete floor underlayments suitable to receive resilient floor coverings. This practice establishes the proper preparation, installation and quality control for thick poured gypsum concrete floor underlayments.4.2 Actual requirements for thick poured gypsum concrete underlayments are generally included as part of project plans or specifications and may vary from the recommendations set forth in this practice. Project plans or specifications, or both, shall supersede the recommendations set forth in this practice.1.1 This practice covers the installation and preparation of the thick poured gypsum concrete underlayments over wood structural panel subfloors in commercial structures or over concrete floors in commercial structures and the preparation of the thick poured gypsum concrete underlayment surface prior to the installation of resilient flooring in commercial buildings.1.2 This practice covers the factors that are required to be controlled while installing thick poured gypsum concrete underlayment as a base for resilient flooring.1.3 This practice does not cover the structural adequacy of the wood structural panel subfloor or concrete subfloor. The structural integrity of assemblies is governed by local building codes.1.4 This practice does not supersede in any manner the thick poured gypsum concrete underlayment manufacturers, adhesive manufacturer’s or resilient flooring manufacturer’s written instructions. Consult the individual manufacturer for specific recommendations.1.5 Thick poured gypsum concrete underlayments are not suitable for use on concrete slabs on ground due to potential moisture problems arising from moisture intrusion, unless an adequate vapor retarder or vapor barrier is present directly beneath the concrete subfloor.1.6 The values stated in inch-pound units are to be regarded as standard. The values stated in parentheses are approximate mathematical conversions to SI units, which are provided for information only.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 Any individual performing a mat bond evaluation should either be a qualified installer or a trained and experienced evaluator of resilient flooring and adhesive bond strength.5.2 This practice should not be considered mandatory, except when required or specified by the end user, general contractor and architect, flooring contractor, adhesive manufacturer(s), underlayment manufacturer(s) or flooring manufacturer(s).5.2.1 Typically, this practice is only recommended or required if products from a different manufacturer(s) are being used in combinations not experienced before or if the substrate preparation or application method is in question.5.3 The number of mat bond evaluation(s) should be selected that is appropriate for the project and be representative of each type of substrate, including trenches, grade, type of flooring, and ambient conditions. The number may also be determined by the responsible party or specified by the end user, general contractor and architect, flooring contractor, adhesive manufacturer(s), underlayment manufacturer(s) or flooring manufacturer(s).5.4 All mat bond evaluation(s) conducted shall have the results recorded within report, including photographs (see A1.11).5.5 There are many factors that may influence the outcome of mat bond evaluation(s). Therefore, it is required to follow each manufacturer(s) installation/application instructions for every product used including open, curing, drying time, and the length of time required prior to evaluation(s)s.5.6 Each step of the process must be conducted only at a time when the subfloor and ambient conditions comply with the requirements defined by all of the relevant manufacturer(s) written installation instructions or Practices F710, F1482, F2419, F2471, F2678, F2873, F3010, or combinations thereof.1.1 This practice is designed to provide a short-term qualitative evaluation of the effectiveness and compatibility of the composite layers for flexible and fully adhered resilient flooring installation(s). Aspects of the resilient flooring assembly to be evaluated may include concrete surface profile (CSP), surface preparation, a topical moisture mitigation system, underlayment product(s), primer(s), application and the installation of the resilient flooring material itself. Aspects such as surface profile, surface cleanliness, surface porosity, the application method(s), and the open, curing, and drying times of each layer of the flooring system can be assessed using this practice prior to the actual full-scale installation taking place.1.1.1 This practice is not intended for use with liquid applied, loose laid or perimeter fixed, or rigid resilient flooring products.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See Section 6 for specific Hazards statements.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
ASTM F1861-21 Standard Specification for Resilient Wall Base Active 发布日期 :  1970-01-01 实施日期 : 

This specification covers resilient wall base. These products are manufactured from rubber or thermoplastic materials, or a combination thereof. Wall base is used to provide a functional, as well as decorative border, between walls and floors. This specification does not include rigid products. Wall base shall be of the following types, as specified: type TS - rubber, vulcanized thermoset, type TP - rubber, thermoplastic, and type TV - vinyl, thermoplastic. Wall base shall be one of the following groups, as specified: group 1 - solid, and group 2 - layered. Wall base shall be of the following styles as specified: style A - straight, style B - cove, style C - butt-to, style D - sculptured. The wear layer thickness, flexibility, adjacent surface straining induced by wall base, light resistance, chemical resistance, dimensional stability, height, thickness, and length shall be tested to meet the requirements prescribed.1.1 This specification covers resilient wall base. These products are manufactured from rubber or thermoplastic materials, or a combination thereof. Wall base is used to provide a functional, as well as decorative border, between walls and floors. This specification does not include rigid products.1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.1.3 The following safety caveat pertains to the test methods portion, Section 12, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

4.1 Resilient floor tile is subjected to impacts from objects that may be inadvertently dropped on to surfaces. It is not possible to know all of the factors related to the dropped objects (shape, weight, height of drop) or the condition of the environment in which the tile is located (types of subfloor, degree of adhesion to subfloor, temperature). Therefore, this test method can only provide a relative measure of resistance of resilient floor tile to impact.1.1 This test method measures the resistance to impact of resilient floor tile.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 618元 / 折扣价: 526 加购物车

在线阅读 收 藏

5.1 This test method is intended as a performance test to provide the user with a set of design values for the test conditions examined.5.1.1 The test method is applicable to all geosynthetics and all soils when loaded in a cyclic manner.5.1.2 This test method produces test data, which can be used in the design of geosynthetic-reinforced pavement structures or in applications where geosynthetics are subjected to cyclic loads.5.1.3 The test results may also provide information related to the in-soil stress-strain response of a geosynthetic under confined loading conditions.5.2 Information derived from this test may be a function of soil gradation, plasticity, as-placed dry unit weight, moisture content, length and surface characteristics of the geosynthetic, and other test parameters. Therefore, results are expressed in terms of the actual test conditions. The test measures the net effect of a combination of interface shear mechanisms, which may vary depending on type of geosynthetic specimen, embedment length, relative opening size, soil type, displacement rate, normal stress, and other factors.5.3 Information between laboratories on precision is incomplete. In cases of dispute, comparative tests to determine if there is a statistical bias between laboratories may be advisable.1.1 This test method details how cyclic loading is applied to geosynthetics embedded in soil to determine the apparent stiffness of the soil–geosynthetic interface.1.2 Resilient interface shear stiffness describes the shear stiffness between a geosynthetic and its surrounding soil under conditions of small cyclic loads.1.3 This test method is intended to provide properties for design. The test method was developed for mechanistic empirical pavement design methods requiring input of the resilient interface shear stiffness. The use of this parameter from this test method for other applications involving cyclic loading should be evaluated on a case-by-case basis. It can also be used to compare different geosynthetics, soil types, etc., and thereby be used as a research and development test procedure.1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

4.1 The combination of both dimensional properties and squareness of resilient floor plank is an important consideration because installed flooring may exhibit an objectionable appearance when either or both characteristics deviate from established tolerances. This test method provides a means of determining length and width dimensions along with squareness, by using a single apparatus and procedure.1.1 This test method establishes the procedures for determination of both dimension (length and width) and squareness of a rectangular resilient floor plank.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are provided in applicable sections of this test method.1.4 The values stated in inch-pounds units are to be regarded as the standard. The values given in parentheses are for information only.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 The effect of dynamic rolling load over resilient floor covering system is important since the resistance reflects the ability of a resilient floor covering system to properly perform under specific use or condition.4.2 Excessive rolling load over an installed resilient floor covering may cause floor covering system failures such as bond failure, delamination, and finish or coating deteriorations.4.3 The effect of dynamic rolling load shall be measured by qualitative evaluation comparing the tested assembly with a standard assembly.1.1 This practice covers the determination of the effect of dynamic rolling load over a resilient floor covering.1.2 This practice is intended to be used by resilient, adhesive and underlayment manufacturers to measure the impact of a dynamic rolling load over a specific product or a combination of products.1.3 This practice may be used to evaluate the performance of joints (sealed or welded) in the resilient floor covering.1.4 This practice may be used to aid in the diagnosis of a specific assembly performance and provide comparative evaluation.1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This guide is intended to be used to determine if there are moisture-related conditions existing in concrete slabs which would adversely impact the successful application and performance of these products.This guide can also be used as an aid in the diagnosis of performance failures in resilient floor covering products.Unless otherwise indicated, these procedures are applicable to slabs on grade, slabs below grade, and slabs above grade (see Terminology F 141).1.1 This guide includes both quantitative and qualitative procedures used to determine the amount of water or water vapor present in or emitting from concrete slabs and criteria for evaluating the moisture-related acceptability of concrete slabs to receive resilient floor coverings and related adhesives.1.2 Although carpet tiles, carpet, wood flooring ceramic tile, stone tile, coatings, films, and paints are not specifically intended to be included in the category of resilient floor coverings, the procedures included in this guide may be useful for evaluating the moisture-related acceptability of concrete slabs for such finishes.1.3 This guide does not cover the adequacy of a concrete floor to perform its structural requirements.1.4 This guide does not include procedures to determine the presence of non-moisture related impediments to the application of finishes.1.5 This guide does not supersede the specific instructions or recommendations of manufacturers for their flooring finishes.1.6 The methods are listed in this guide for reference purposes only. Refer to Practice F 710 and the flooring manufacturer for acceptable quantitative methods. For acceptance, refer to Practice F 710.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

4.1 This practice provides minimum recommendations for the installation of thick poured lightweight cellular concrete floor underlayments suitable to receive resilient floor coverings. This practice establishes the proper preparation, installation and quality control for thick poured lightweight cellular concrete floor underlayments.4.2 Actual requirements for thick poured lightweight cellular concrete underlayments are generally included as part of project plans or specifications and may vary from the recommendations set forth in this practice. Project plans or specifications, or both, shall supersede the recommendations set forth in this practice.1.1 This practice covers the installation and preparation of the thick poured lightweight cellular concrete underlayments over wood structural panel subfloors in commercial structures or over concrete floors in commercial structures and the preparation of the thick poured lightweight cellular concrete underlayment surface prior to the installation of resilient flooring in commercial buildings.1.2 This practice points out the factors that are required to be controlled while installing thick poured lightweight cellular concrete underlayment as a base for resilient flooring.1.3 This practice does not cover the structural adequacy of the wood structural panel subfloor or concrete subfloor. The structural integrity of assemblies is governed by local building codes.1.4 This practice does not supercede the thick poured lightweight cellular concrete underlayment manufacturers', adhesive manufacturers' or resilient flooring manufacturers' written instructions. Consult the individual manufacturer for specific recommendations.1.5 Thick poured lightweight cellular concrete underlayments are not suitable for use on concrete slabs on ground due to potential moisture problems arising from moisture intrusion, unless an adequate vapor retarder or vapor barrier is present directly beneath the concrete subfloor.1.6 The values stated in inch-pound units are to be regarded as standard. The values stated in parentheses are mathematical conversions to SI Units, which are provided for information only.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

1.1 This practice addresses criteria pertinent to the selection of resilient residential flooring including properties of materials, end use, environment, and maintenance. It applies to all non-textile resilient floor coverings. Documents developed according to this practice shall address all characteristics and materials within the scope of this practice.