1.1 This specification covers an adhesive lubricant for facilitating the insertion and positioning of preformed elastomeric bridge compression seals in either concrete or steel-faced joints, and which bonds the seal to the joint faces to waterproof the joint.1.2 Since a precision estimate for this standard has not been developed, this test method is to be used for research or informational purposes only. Therefore, this test should not be used for acceptance or rejection of a material for purchasing purposes.1.3 SI units are the standard. Units in parentheses are for information only.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

3.1 This practice provides the three principal methods of fitting chocks to marine machinery foundations to ensure that the machinery is free of vibration and perfectly aligned after installation.3.1.1 The three principal methods of installing chocks described herein are as follows:3.1.1.1 Type A—Epoxy-based resin, nonshrinking, and3.1.1.2 Type B—Two-piece wedge chocks.3.1.1.3 Type C—Solid, one-piece fitted chocks.1.1 This practice covers the acceptable methods of fitting chocks to marine machinery foundations.1.2 The values stated in SI units shall be regarded as standard. The values in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

5.1 This practice is for use by designers and specifiers, regulatory agencies, owners, and inspection organizations who are involved in the installation of a sewer service cleanout.1.1 This practice covers (i) installation methods, test methods, and required materials for the installation of a sewer service clean out, by means of a small vacuum excavated borehole, and (ii) same-day site restoration. The utilization of this practice greatly reduces disruption and greatly improves safety for to residents, business owners, and the public.1.2 Units—The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 The direct push ground method is a rapid and economical procedure for installing groundwater monitoring wells to obtain representative groundwater samples and location-specific hydrogeologic measurements. Direct push installations may offer an advantage over conventional rotary drilled monitoring wells (Practice D5092) for groundwater explorations in unconsolidated formations because they reduce disturbance to the formation, and eliminate or minimize drill cuttings. At facilities where contaminated soils are present, this can reduce hazard exposure for operators, local personnel, and the environment, and can reduce investigative derived wastes. Additionally, smaller equipment can be used for installation, providing better access to constricted locations.5.2 Direct push monitoring wells are typically smaller in diameter than drilled wells, thereby reducing purge water volumes, sampling time, and investigative derived wastes. Practice D5092 monitoring wells are used when larger diameters and/or sample volumes are required, or at depths or in geologic formations to where it is difficult to install direct push wells. Direct push monitoring wells should be viable for monitoring for many years.5.3 Prior to construction and installation of a direct push well or any other type of groundwater well the reader should consult appropriate local agencies regarding regulatory requirements for well construction. A regulatory variance may be required for installation of direct push monitoring wells.5.4 To date, published comparison studies between drilled monitoring wells and direct push monitoring wells have shown comparability (1-10)4. However, selection of direct push monitoring wells over conventional rotary drilled wells should be based on several criteria, such as site accessibility and penetrability, stratigraphic structure, depth to groundwater, and aquifer transmissivity.5.5 Typical penetration depths for installation of groundwater monitoring wells with direct push equipment depend on many variables. Some of the variables are the size and type of the driving system, diameter of the drive rods and monitoring well, and the resistance of the earth materials being penetrated. Some direct push systems are capable of installing groundwater monitoring wells to depths in excess of 100 ft [30 m], and larger direct push equipment can reach depths of several hundred feet. However, installation depths of 10 to 50 ft [5 to 15 m] are most common. Direct push methods cannot be used to install monitoring wells in consolidated bedrock (for example, granite, limestone, gneiss), but are intended for installation in unconsolidated materials such as clays, silts, sands, and some gravels. Additionally, deposits containing significant cobbles and boulders (for example, some glacial deposits), or strongly cemented materials (for example, caliche) are likely to hinder or prevent penetration to the desired monitoring depth.5.6 For direct push methods to provide accurate groundwater monitoring results, precautions must be taken to ensure that cross-contamination by “smearing” or “drag-down” (that is, driving shallow contamination to deeper levels) does not occur, and that hydraulic connections between otherwise isolated water bearing strata are not created. Similar precautions as those applied during conventional rotary drilling operations (Guide D6286) should be followed.5.7 There have been no conclusive comparisons of effectiveness of sealing between drilled monitoring wells and direct push monitoring wells. As with drilled monitoring wells, sealing methods must be carefully applied to be effective. Research on well sealing (11) has shown that bentonite seals are not effective above the water table and that if used bentonite grout requires a minimum of 20 % solids.5.8 Selection of direct push monitoring wells versus conventional rotary drilled monitoring wells should be based on many issues. The advantages and disadvantages of the many available types of driving equipment and well systems must be considered with regard to the specific site conditions. Specific well systems and components, as well as direct push driving equipment, are described in Section 7.5.9 Advantages: 5.9.1 Minimally intrusive and less disturbance of the natural formation conditions than many conventional drilling techniques.5.9.2 Rapid and economical.5.9.3 Smaller equipment with easier access to many locations.5.9.4 Use of shorter screens can eliminate connections between multiple aquifers providing better vertical definition of water quality than long well screens. Shorter screens are also more effective at identifying contaminated zones in heterogeneous formation conditions.5.9.5 Generates little or potentially no contaminated drill cuttings.5.9.6 Less labor intensive than most conventional drilling techniques.5.10 Disadvantages: 5.10.1 Cannot be used to install monitoring devices in consolidated bedrock and deposits containing significant cobbles and boulders.5.10.2 Small diameter risers and screens limit the selection of useable down-hole equipment for purging and sampling.5.10.3 Difficulty installing sand pack in small annular space if gravity installation of sand pack is used.5.10.4 Difficulty installing grout in same annular space unless appropriately designed equipment is used.NOTE 1: The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors.Practice D3740 was developed for agencies engaged in the laboratory testing and/or inspection of soils and rock. As such, it is not totally applicable to agencies performing this field practice. However, user of this practice should recognize that the framework of Practice D3740 is appropriate for evaluating the quality of an agency performing this practice. Currently there is no known qualifying national authority that inspects agencies that perform this practice.1.1 This guide describes various direct push groundwater monitoring wells and provides guidance on their selection and installation for obtaining representative groundwater samples and monitoring water table elevations. Direct push wells are used extensively for monitoring groundwater quality in unconsolidated formations. This guide also includes discussion of some groundwater sampling devices which can be permanently emplaced as monitoring wells.1.2 This guide does not address the single event sampling of groundwater using direct push water samplers as presented in Guide D6001. The methods in this guide are often used with other tests such as direct push soil sampling (Guide D6282) and the cone penetrometer test (Guide D6067). The guide does not address the installation of monitoring wells by rotary drilling or sonic drilling methods such as those presented in Practice D5092. Techniques for obtaining groundwater samples from monitoring wells are covered in Guides D4448, D7929, and Practice D6771. Practice D6725 addresses direct push wells using pre-packed screens.1.3 The installation of direct push groundwater monitoring wells is limited to unconsolidated soils and sediments including clays, silts, sands, and some gravels and cobbles. Penetration may be limited, or damage may occur to equipment, in certain subsurface conditions; some of which are discussed in 5.5. Information in this guide is limited to groundwater monitoring in the saturated zone.1.4 The values stated in either inch-pound units or SI units presented in brackets are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.5 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026, unless superseded by this standard.1.6 This guide offers an organized collection of information or a series of options and does not recommend a specific course of action. This document cannot replace education or experience and should be used in conjunction with professional judgement. Not all aspects of this guide may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project’s many unique aspects. The word “Standard” in the title of this document means only that the document has been approved through the ASTM consensus process.1.6.1 This guide does not purport to comprehensively address all of the methods and issues associated with monitoring well installation. Users should seek input from qualified professionals for the selection of proper equipment and methods that would be the most successful for their site conditions. Other methods may be available for monitoring well installation, and qualified professionals should have flexibility to exercise judgement concerning alternatives not covered in this guide. The practice described in this guide is current at the time of issue; however, new, alternative, and innovative methods may become available prior to revisions. Therefore, users should consult with manufacturers or producers prior to specifying program requirements.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

5.1 This practice is intended to provide the user with information on the appropriate methods and procedures for installing prepacked screen monitoring wells by direct push methods. The monitoring wells may be used to obtain representative water quality samples for aqueous phase contaminants or other analytes of interest, either organic or inorganic (3, 6-8). The monitoring wells may also be used to obtain information on the potentiometric surface of the local aquifer and properties of the formation such as hydraulic conductivity or transmissivity.5.2 Use of direct push methods to install monitoring wells can significantly reduce the amount of potentially hazardous drill cuttings generated during well installation at contaminated sites. This may significantly reduce cost of an environmental site investigation and groundwater monitoring program. Minimizing generation of hazardous waste also reduces the exposure hazards to site workers, local residents, and the environment.5.3 Direct push methods for monitoring well installation are limited to use in unconsolidated formations such as alluvial/stream sediments, glacial deposits, and beach type sediments. Direct push methods are generally successful at penetrating clays, silts, sands and some gravel. Deposits such as soils with thick caliche layers, or glacial tills with large cobbles or boulders may be difficult or impossible to penetrate to the desired depth. Direct push methods are not designed for penetration of consolidated bedrock such as limestone, granite or gneiss.NOTE 1: The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors.Practice D3740 was developed for agencies engaged in the laboratory testing and/or inspection of soils and rock. As such, it is not totally applicable to agencies performing this field practice. However, user of this practice should recognize that the framework of Practice D3740 is appropriate for evaluating the quality of an agency performing this practice. Currently there is no known qualifying national authority that inspects agencies that perform this practice.1.1 This practice is based on recognized methods by which direct push monitoring wells may be designed and installed for the purpose of detecting the presence or absence of a contaminant, and collecting representative groundwater quality data. The design standards and installation procedures herein are applicable to both detection and assessment monitoring programs for facilities.1.2 The recommended monitoring well design, as presented in this practice, is based on the assumption that the objective of the program is to obtain representative groundwater information and water quality samples from aquifers. Monitoring wells constructed following this practice should produce relatively turbidity-free samples for granular aquifer materials ranging from gravels to silty sand.1.3 Direct push procedures are not applicable for monitoring well installation under all geologic and soil conditions (for example, installation in bedrock). Other rotary drilling procedures are available for penetration of these consolidated materials for well construction purposes (Guide D5092). Additionally, under some geologic conditions it may be appropriate to install monitoring wells without a filter pack (1, 2)2. Guide D6724 may be referred to for additional information on these and other methods for the direct push installation of groundwater monitoring wells.1.4 The values stated in either inch-pound units or SI units presented in brackets are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.5 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026, unless superseded by this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.7 This practice offers a set of instructions for performing one or more specific operations. This document cannot replace education or experience and should be used in conjunction with professional judgement. Not all aspects of this practice may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of the project's many unique aspects. The word “Standard” in the title of this document means only that the document has been approved through the ASTM consensus process.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

This specification covers the dimensional, design, and performance requirements for five types (Types EB-20, EB-35, DB-60, DB-100, and DB-120) of smooth-wall poly(vinyl chloride) (PVC) conduits and fittings for underground communication and electrical power wires and cables. Conduits and fittings shall be evaluated on impact resistance and strength, joint tightness, pipe stiffness, and extrusion quality.1.1 This specification covers the requirements for single wall and coextruded cellular core smooth-wall poly(vinyl chloride) conduit and fittings for underground communication and electrical power wire and cables. Plastics which does not meet the material requirements specified in Section 5 is excluded from single layer and all coextruded layers.1.2 The values given in parentheses are for information only.1.3 The following safety hazards caveat pertains only to the test method portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

4.1 This guide recommends minimum installation requirements to provide a reasonable degree of safety in the normal use of paintball barrier netting.1.1 This guide provides recommendations for the installation of paintball barrier netting that may be used to delineate playing fields, chronograph areas, target ranges, and other “goggle-on” areas of an active paintball site.1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units in parentheses are provided for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
127 条记录,每页 15 条,当前第 9 / 9 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页