This guide shows the basis for the acceptability criterion of ±4 dB for the site attenuation measurements required in ANSI C63.4-1992.

定价: 113元 / 折扣价: 97

在线阅读 收 藏

This guide describes significant aspects of handling SF6 gas used in electric power equipment, such as gas recovery, reclamation, and recycling, in order to keep the gas permanently in a closed cycle and to avoid any deliberate release into the environment.

定价: 106元 / 折扣价: 91

在线阅读 收 藏

This standard defines an architecture required to implement a virtual reality system that can simulate responses to possible disasters in physical spaces, where users can actually move around with six degrees of freedom, for training. This reference architecture includes the physical-to-virtual component that transfers sensor data in the physical space to the virtual world, the virtual-to-virtual component that conveys the data between virtual world objects, and the virtual-to-physical… read more component that transfers the simulated responses in the virtual world to actuators in the physical world. read less

定价:

在线阅读 收 藏

This guide describes aspects of the handling of SF6 gas used in electric power equipment, such as gas filling, recovery, reclamation, testing, quality analysis and recycling, in order to keep the gas permanently in a closed loop system and to avoid any release into the environment.

定价: 85元 / 折扣价: 73

在线阅读 收 藏

This International Standard specifies computational procedures using Finite-Difference Time-Domain (FDTD) and Finite Element Methods (FEM) to assess the peak and spatial-averaged power density relevant to the human exposure of the human head or body from devices operating between 6 GHz and 300 GHz. It applies to devices with radiating structures at distances up to and including 200 mm. This includes but is not limited to mobile phones, tablets, and wearables. This standard provides a… read more conservative estimate of the power density of the exposure of the head or body for a significant majority of persons during normal use of these devices. read less

定价: 0元 / 折扣价: 0

在线阅读 收 藏

This document is applicable to single and three-phase wet-mateable and dry-mateable AC connectors, penetrators and jumper assemblies with rated voltages from 3 kV (Umax = 3,6 kV) to 30 kV (Umax = 36 kV). This document relates to the requirements and tests for products in the "as manufactured and supplied" condition. This document is not applicable to requirements and tests for products that have been subsequently installed, deployed or retrieved.

定价: 110元 / 折扣价: 94

在线阅读 收 藏

This document specifies computational procedures for conservative and reproducible computations of power density (PD) incident to a human head or body due to radiofrequency (RF) electromagnetic field (EMF) transmitting devices. The computational procedures described are finite-difference time-domain (FDTD) and finite element methods (FEM), which are computational techniques that can be used to determine electromagnetic quantities by solving Maxwell's equations within a specified computational… read more uncertainty. The procedures specified here apply to exposure evaluations for a significant majority of the population during the use of hand-held and body-worn RF transmitting devices. The methods apply to devices that can feature single or multiple transmitters or antennas, and that can be operated with their radiating part or parts at distances up to 200 mm from a human head or body. This document can be employed to determine conformity with any applicable maximum PD requirements of different types of RF transmitting devices used in close proximity to the head and body, including those combined with other RF transmitting or non-transmitting devices or accessories (e.g. belt-clip), or embedded in garments. The overall applicable frequency range of these protocols and procedures is from 6 GHz to 300 GHz. The RF transmitting device categories covered in this document include but are not limited to mobile telephones, radio transmitters in personal computers, desktop and laptop devices, and multi-band and multi-antenna devices. The procedures of this document do not apply to PD evaluation of electromagnetic fields emitted or altered by devices or objects intended to be implanted in the body. read less

定价: 160元 / 折扣价: 136

在线阅读 收 藏

This document specifies protocols and test procedures for repeatable and reproducible measurements of power density (PD) that provide conservative estimates of exposure incident to a human head or body due to radio-frequency (RF) electromagnetic field (EMF) transmitting communication devices, with a specified measurement uncertainty. These protocols and procedures apply for exposure evaluations of a significant majority of the population during the use of hand-held and body-worn RF transmitting communication devices. The methods apply for devices that can feature single or multiple transmitters or antennas, and can be operated with their radiating structure(s) at distances up to 200 mm from a human head or body. The methods of this document can be used to determine conformity with applicable maximum PD requirements of different types of RF transmitting communication devices being used in close proximity to the head and body, including if combined with other RF transmitting or nontransmitting devices or accessories (e.g. belt-clip), or embedded in garments. The overall applicable frequency range of these protocols and procedures is from 6 GHz to 300 GHz. The RF transmitting communication device categories covered in this document include but are not limited to mobile telephones, radio transmitters in personal computers, desktop and laptop devices, and multi-band and multi-antenna devices.

定价: 193元 / 折扣价: 165

在线阅读 收 藏

This part of IEC/IEEE 62704 describes the concepts, techniques, and limitations of the finite element method (FEM) and specifies models and procedures for verification, validation and uncertainty assessment for the FEM when used for determining the peak spatial-average specific absorption rate (psSAR) in phantoms or anatomical models. It recommends and provides guidance on the modelling of wireless communication devices, and provides benchmark data for simulating the SAR in such phantoms or models. This document does not recommend specific SAR limits because these are found elsewhere (e.g. in IEEE Std C95.1 [1]1 or in the guidelines published by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) [2]).

定价: 112元 / 折扣价: 96

在线阅读 收 藏

The project defines the concepts, techniques, benchmark phone models, validation procedures, uncertainties and limitations of the finite difference time domain (FDTD) technique when used for determining the peak spatial-average specific absorption rate (SAR) in standardized head and body phantoms exposed to the electromagnetic fields generated by wireless communication devices, in particular pre-compliance assessment of mobile phones, in the frequency range from 30 MHz to 6 GHz. It recommends… read more and provides guidance on the numerical modelling of mobile phones and benchmark results to verify the general approach for the numerical simulations of such devices. It defines acceptable modeling requirements, guidance on meshing and test positions of the mobile phone and the phantom models. This document does not recommend specific SAR limits since these are found in other documents, e.g., IEEE C95.1-2005 and ICNIRP. read less

定价: 104元 / 折扣价: 89

在线阅读 收 藏

The scope of this standard is to define the methodology for the application of the finite difference time domain (FDTD) technique when used for determining the peak spatial-average specific absorption rate (SAR) in the human body exposed to wireless communication devices with known uncertainty. It defines methods to validate the numerical model of the device under test (DUT) and to assess its uncertainty when used in SAR simulations. Moreover, it defines procedures to determine the peak spatial… read more average SAR in a cubical volume and to validate the correct implementation of the FDTD simulation software. This document will not recommend specific SAR limits since these are found elsewhere, e.g., in the guidelines published by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) or in IEEE C95.1. read less

定价: 104元 / 折扣价: 89

在线阅读 收 藏

This standard defines the methodology for the application of the finite difference time domain (FDTD) technique when used for determining the peak spatial-average specific absorption rate (SAR) in the human body exposed to wireless communication devices with known uncertainty. It defines methods to validate the numerical model of the device under test (DUT) and to assess its uncertainty when used in SAR simulations. Moreover, it defines procedures to determine the peak spatial average SAR in a cubical volume and to validate the correct implementation of the FDTD simulation software. This document does not recommend specific SAR limits since these are found elsewhere, e.g., in the guidelines published by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) or in IEEE C95.1.

定价: 97元 / 折扣价: 83

在线阅读 收 藏

This part of IEC/IEEE 62704 establishes the concepts, techniques, validation procedures, uncertainties and limitations of the finite difference time domain technique (FDTD) when used for determining the peak spatial-average and whole-body average specific absorption rate (SAR) in a standardized human anatomical model exposed to the electromagnetic field emitted by vehicle mounted antennas in the frequency range from 30 MHz to 1 GHz, which covers typical high power mobile radio products and… read more applications. This document specifies and provides the test vehicle, human body models and the general benchmark data for those models. It defines antenna locations, operating configurations, exposure conditions, and positions that are typical of persons exposed to the fields generated by vehicle mounted antennas. The extended frequency range up to 6 GHz will be considered in future revisions of this document. This document does not recommend specific peak spatial-average and whole-body average SAR limits since these are found in other documents, e.g. IEEE C95.1-2005, ICNIRP (1998). read less

定价: 159元 / 折扣价: 136

在线阅读 收 藏

The scope of this project is to describe the concepts, techniques, models, validation procedures, uncertainties and limitations of the finite-difference time-domain technique (FDTD) when used for determining the spatial-peak specific absorption rate (SAR) in standardized human anatomical models.These models are exposed to personal wireless devices, e.g. mobile phones. It recommends and provides guidance on modeling of personal wireless devices and provides benchmark data for simulation of such models. It defines model contents and provides guidance on meshing and test positions at the anatomical models. This document does not recommend specific SAR values since these are found in other documents, e.g., IEEE C95.1 and IEEE C95.1a.

定价: 58元 / 折扣价: 50

在线阅读 收 藏