微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 0元 / 折扣价: 0

在线阅读 收 藏

定价: 0元 / 折扣价: 0

在线阅读 收 藏

定价: 884元 / 折扣价: 752

在线阅读 收 藏

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏

定价: 936元 / 折扣价: 796 加购物车

在线阅读 收 藏

5.1 This practice is intended for use as a voluntary standard by parties who wish to undertake the seismic risk assessment of properties. The goal is for users to objectively and reliably compare the financial risks of earthquake damage to buildings, or groups of buildings, on a consistent basis.5.2 This practice is designed to provide requirements for the evaluation of earthquake damage risk so that technical reports prepared for the evaluation and rating of seismic risk of a building(s) will be adequate for use by other entities. Potential users including, but are not be limited to, those making equity investments, lending, and financial transactions, including securitized mortgage lending by mortgage originators, loan servicers, underwriters, rating agencies, and purchasers of bonds secured by the real estate.5.3 The use of this practice may permit a user to satisfy, in part, their requirements for due diligence in assessing a property's potential for losses associated with earthquakes for real estate transactions.1.1 This practice establishes standard-of-care for evaluation and classification of the financial risks from earthquake damage to real estate improvements for use in financial mortgage transactions and capital investment evaluation. As such, this practice permits a user to satisfy, in part, their real estate transaction due-diligence requirements with respect to assessing and characterizing a property’s potential losses from earthquakes. This practice is intended to address only physical damage to the property from site and building response.1.1.1 Hazards addressed in this practice include earthquake ground shaking, earthquake-caused site instability, including faulting, subsidence, settlement landslides and soil liquefaction, earthquake-caused tsunamis and seiches, and earthquake-caused flooding from dam or dike failures.1.1.2 Earthquake-caused fires and toxic materials releases are not hazards considered in this practice.1.1.3 This practice does not purport to provide for the preservation of life safety, or prevention of building damage associated with its use, or both.1.1.3.1 This practice does not address requirements of any federal, state, or local laws and regulations of building construction or maintenance. Users are cautioned that current federal, state, and local laws and regulations may differ from those in effect at the times of construction or modification of the building(s), or both.1.1.3.2 This practice does not address the contractual and legal obligations between prior and subsequent Users of seismic risk assessment reports or between providers who prepared the report and those who would like to use such prior reports.1.1.3.3 This practice does not address the contractual and legal obligations between a provider and a user, and other parties, if any.1.1.4 It is the responsibility of the owner of the building(s) to establish appropriate life-safety and damage prevention practices and determine the applicability of current regulatory limitations prior to use.1.2 Considerations not included in the scope: the impacts of damage to contents, loss of income(s), rents, or other economic benefits of use of the property, or from legal judgments, fire sprinkler water-induced damage or fire.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

3.1 This practice is a prescriptive set of installation methods to be used for suspended ceilings and is often used in lieu of designing a separate lateral restraint system. The authority having jurisdiction shall determine the applicability of this practice to local code requirements.3.2 This practice covers installation of suspended ceiling systems and related components in areas that require resistance to the effects of earthquake motions as defined by ASCE 7 and the International Building Code.3.3 The practice is broken into two main sections. The first section covers areas with light to moderate earthquake potential (Seismic Design Category C) while the second deals with severe earthquake potential (Seismic Design Category D, E & F).3.4 This practice includes requirements from multiple sources including previous versions of this practice, CISCA Seismic Recommendations for Direct-hung Acoustical Tile and Lay-in Ceilings, Seismic Zones 0-2 and CISCA Guidelines for Seismic Restraint for Direct Hung Suspended Ceiling Assemblies, Seismic Zones 3 & 4, suspended ceiling requirements from the International Building Code and ASCE 7. The purpose is to combine the requirements from these sources into a single comprehensive document.AbstractThis practice covers acoustical ceiling suspension systems and their additional requirements for application in areas subject to light to moderate seismic disturbance such as Uniform Building Code Seismic Zone 2, the BOCA Basic National Building Code where Av is less than 0.20 but greater than 0.10, and the Standard Building Code (SBC) where Av is less than 0.20 but greater than 0.05. This practice also covers areas subject to moderate to severe seismic disturbance such as Uniform Building Code Seismic Zones 3 and 4, the BOCA Basic National Building Code where Av is greater than 0.20, and the SBC where Av is greater than 0.20. The application of this practice is to be determined by local authorities. Current seismic maps published by recognized authorities such as those previously mentioned, as well as related material such as Open File 82-1033 and MS-812 Seismicity Maps, should be consulted. This practice is not intended to stifle research and development of new products or methods which may simplify the application method specified herein. A variation, however, must be substantiated by verifiable engineering data. A ceiling area of 144 ft2 [13m2] or less, surrounded by walls that connect directly to the structure above shall be exempt from this practice.1.1 This practice covers the installation of suspended systems for acoustical tile and lay-in panels and their additional requirements for two groups of buildings that are constructed to resist the effects of earthquake motions as defined by ASCE 7 and the International Building Code. These groupings are for Seismic Design Category C and Seismic Design Categories D, E and F.1.2 The authority having jurisdiction shall determine the applicability of this practice.1.3 Test Methods E3090/E3090M, Specification C635, and Practice C636 cover suspension systems, their installation, and testing without special regard to seismic lateral restraint needs. They remain applicable and shall be followed when this practice is specified.1.4 Ceilings less than or equal to 144 ft2 [13.4 m2] and surrounded by walls connected to the structure above are exempt from the requirements of this practice.1.5 This practice is not intended to stifle research and development of new products or methods. This practice is not intended to prevent the installation of any material or prohibit any design or method of construction not prescribed in this practice, provided that any such alternative has been substantiated by verifiable engineering data or full-scale dynamic testing that is acceptable to the authority having jurisdiction.1.6 Ceiling areas of 1000 ft2 [92.9 m2] or less shall be exempt from the lateral force bracing requirements of 5.2.8.1.7 Ceilings constructed of gypsum board which is screw or nail attached to suspended members that support a ceiling on one level extending from wall to wall shall be exempt from the requirements of this practice.1.8 Free floating ceilings (those not attached directly to any structural walls) supported by chains or cables from the structure are not required to satisfy the seismic force requirements provided they meet the following requirements:1.8.1 The design load for such items shall equal 1.4 times the vertical operating weight.1.8.2 Seismic interaction effects shall be considered in accordance with 5.7.1.8.3 The connection to the structure shall allow a 360° range of motion in the horizontal plane.1.9 The values stated in either inch-pound or SI units are to be regarded as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems result in nonconformance with the specification.1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

5.1 This practice provides a standardized installation procedure for ceilings designed and installed as a diaphragm. When installed according to this practice, these ceilings have sufficient strength to resist seismic forces without lateral force bracing.1.1 This practice covers the installation requirements of direct hung suspended t-bar type ceiling systems intended to receive gypsum panel products constructed as flat, single level, surrounded on all sides by a wall, bulk head, or soffit braced to the building structure to resist the effects of earthquake ground motions.1.2 Ceiling assembly shall not be intended to support live loads.1.3 This standard addresses ceiling systems with dead loads up to 10 lbs/ft2 (48.8 kg/m2).1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.5 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
10 条记录,每页 15 条,当前第 1 / 1 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页