微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

4.1 This practice is used to outline the minimum necessary elements and conditions to obtain an accurate determination of the location of wet insulation in roofing systems using infrared imaging.4.2 This practice is not meant to be an instructional document or to provide all the knowledge and background necessary to provide an accurate analysis. For further information, see ANSI-ASHRAE Standard 101 and ISO/DP 6781.3E.4.3 This practice does not provide methods to determine the cause of moisture or its point of entry. It does not address the suitability of any particular system to function capably as waterproofing.1.1 This practice applies to techniques that employ infrared imaging at night to determine the location of wet insulation in roofing systems that have insulation above the deck in contact with the waterproofing. This practice includes ground-based and aerial inspections. (Warning—Extreme caution shall be taken when accessing or walking on roof surfaces and when operating aircraft at low altitudes, especially at night.) (Warning—It is a good safety practice for at least two people to be present on the roof surface at all times when ground-based inspections are being conducted.)1.2 This practice addresses criteria for infrared equipment such as minimum resolvable temperature difference, spectral range, instantaneous field of view, and field of view.1.3 This practice addresses meteorological conditions under which infrared inspections shall be performed.1.4 This practice addresses the effect of roof construction, material differences, and roof conditions on infrared inspections.1.5 This practice addresses operating procedures, operator qualifications, and operating practices.1.6 This practice also addresses verification of infrared data using invasive test methods.1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 1.1.1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

5.1 Personnel responsible for the creation, display, transfer or storage of digital nondestructive evaluation results will use this guide.5.2 Personnel responsible for the design and manufacture of NDT systems conforming to the DICONDE standard will use this guide.5.3 Personnel responsible for the purchase and implementation of NDT systems conforming to the DICONDE standard will use this guide.5.4 This guide will recommend courses of action for utilizing the DICONDE standard for the use cases described in 5.1, 5.2, and 5.3.1.1 The display, transfer and storage of digital nondestructive evaluation data in a common, open format is necessary for the effective interpretation and preservation of evaluation results. ASTM International has developed common open standards for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) based on the ubiquitous healthcare industry standard Digital Imaging and Communication in Medicine (DICOM). This guide provides an overview of the ASTM International standard practices that address DICONDE and assistance in identifying the correct standard practices for different use cases.1.2 This document provides an overview of how to utilize the ASTM DICONDE standard practices found in paragraph 2.1.2 on ASTM DICONDE Test Methods Standards for the display, transfer and storage of digital nondestructive test data1.3 This document provides an overview of how to utilize the DICOM standard found in paragraph 2.2 on Other Documents for the display, transfer and storage of digital nondestructive test data for test methods not explicitly addressed by a DICONDE standard practice but having an equivalent medical imaging modality.1.4 This document provides recommendations for the display, transfer and storage of nondestructive digital test data not addressed in 1.2 or 1.3.1.5 This document provides an overview of how to utilize the ASTM DICONDE standard practices found in paragraph 2.1.3 on ASTM DICONDE Interoperability Standards for validating a system that follows the ASTM DICONDE standard for the display, transfer and storage of digital nondestructive test data.1.6 This document provides an overview of how to utilize the ASTM DICONDE standard practices found in 2.1.3 for validating that two or more systems that follow the ASTM DICONDE standard for the transfer of digital nondestructive test data can successfully transfer data.1.7 This document provides an overview of how to utilize the ASTM DICONDE standard practices found in 2.1.3 for validating that two or more systems that follow the ASTM DICONDE standard for the display of digital nondestructive test data display data consistently.1.8 Although this guide contains no values that require units, it does describe methods to store and communicate data that do require units to be properly interpreted. The SI units required by this guide are to be regarded as standard. No other units of measurement are included in this guide.1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

This test method provides a means of evaluating and comparing development of corrosion at scribe on painted/coated flat test panels after exposure to corrosive environments.1.1 This test method covers the measurement of rust creepage area from a scribe line on painted/coated flat test panels after exposure to corrosive environments. This test method has the advantage of simplicity and ease of use. Expensive equipment is not required, and the results are more accurate than visual evaluation but not as precise as advanced digital imaging. 1.2 This test method uses visual imaging software to determine the area damaged by rust creepage from the scribe. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

5.1 The ability to correlate results of analyzers to sieve sets enables the use of non-sieve methods to be employed that give comparable results to each other.5.2 The use of analyzers for proppant measurement has the benefit of providing particle shape characteristics which are important in the performance of these materials. Shape analysis is currently done by operator’s determination based on a visual observation of a small number of particles per API 19C. Available information from imaging analysis of many particles can be used to assess the proppant shape characteristics as opposed to just a small number.1.1 This practice describes procedural steps to create a correlation that can be used to compare results of proppant size distributions between dynamic imaging analyzers (analyzers) and prescribed sieve sets.1.2 The proppant size and distribution specifications that are included in this practice are listed in API Standard 19C (API 19C) and shown in Table 1, however as industry evolves additional specifications may come into use and this practice can be used with those as well.1.3 This practice may not be applicable to all proppant types and designations. The acceptability of the correlations determined are judged by the operator.1.4 The values stated in SI units are to be regarded as the standard, except sieve designations are typically identified using the ‘alternative’ system in accordance with Practice E11, such as 3 in. and No. 200 instead of the ‘standard’ system of 75 mm and 75 µm, respectively.1.5 Observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026, unless superseded by this standard.1.5.1 The procedures used to specify how data are collected/recorded and calculated in Practice D6026 are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user’s objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of these test methods to consider significant digits used in analysis methods for engineering data.1.6 This practice offers a set of instructions for performing one or more specific operations. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this practice may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project’s many unique aspects. The word “Standard” in the title means only that the document has been approved through the ASTM consensus process.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

5.1 Personnel that are responsible for the transfer of NDE data between systems will use this standard. This practice will define a set of NDE information object definitions that along with the DICOM standard will provide a standard means to organize image data. Once conformance statements have been generated, the NDE image data may be displayed on any imaging/analysis device that conforms to the standard. This process of developing conformance statements with both the NDE specific object definitions and the DICOM accepted definitions, will provide a means to automatically and transparently communicate between compliant equipment without loss of information.NOTE 1: Knowledge and understanding of the existing DICOM standard will be required to generate conformance statements and thereby facilitate the data transfer.1.1 This practice facilitates the interoperability of NDE imaging and data acquisition equipment by specifying the image data in commonly accepted terms. This practice represents a harmonization of NDE imaging systems, or modalities, with the NEMA Standards Publication titled Digital Imaging and Communications in Medicine (DICOM, see http://medical.nema.org), an international standard for image data acquisition, review, storage and archival. In addition, this practice will provide a standard set of industrial NDE specific information object definitions, which travel beyond the scope of standard DICOM modalities. The goal of this practice is to provide a standard by which NDE image/signal data may be displayed on by any system conforming to the ASTM DICONDE format, regardless of which NDE modality was used to acquire the data.1.2 This practice has been developed to overcome the issues that arise when archiving or analyzing the data from a variety of NDE techniques, each using proprietary data acquisition systems. As data acquisition modalities evolve, data acquired in the past must remain decipherable. This practice proposes an image data file format in such a way that all the technique parameters, along with the image file, are preserved, regardless of changes in NDE technology. This practice will also permit the viewing of a variety of image types (CT, CR, Ultrasonic, Infrared, and Eddy Current) on a single workstation, maintaining all of the pertinent technique parameters along with the image file. This practice addresses the exchange of digital information between NDE imaging equipment.1.3 This practice does not specify:1.3.1 A complete description of all the information necessary to implement the DICONDE standard for an imaging modality. This document must be used in conjunction with one of the method-specific DICONDE Standard Practice documents and the DICOM Standard to completely describe all the requirements necessary to implement the DICONDE standard for an imaging modality. See 2.1 of this document for a current list of the method-specific standard practice documents.1.3.2 A testing or validation procedure to assess an implementation's conformance to the standard. Best practices for demonstrating conformance can be found in Practice E3147.1.3.3 The implementation details of any features of the standard on a device claiming conformance.1.3.4 The overall set of features and functions to be expected from a system implemented by integrating a group of devices each claiming DICONDE or DICOM conformance.1.4 Units—Although this practice contains no values that require units, it does describe methods to store and communicate data that do require units to be properly interpreted. The SI units required by this practice are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

5.1 This practice relates to a thermal imaging system's effectiveness for discerning details in a scene.5.2 MRTD values provide estimates of resolution capability and may be used to compare one system with another. (Lower MRTD values indicate better resolution.)5.3 Due to the partially subjective nature of the procedure, repeatability and reproducibility are apt to be poor and MRTD differences less than 0.2 °C are considered to be insignificant.NOTE 1: Values obtained under idealized laboratory conditions may or may not correlate directly with service performance.1.1 This practice covers the determination of the minimum resolvable temperature difference (MRTD) capability of the compound observer-thermal imaging system as a function of spatial frequency.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 Personnel that are responsible for the creation, transfer, and storage of eddy current NDE test results will use this standard. This practice defines a set of information modules that, along with Practice E2339 and the DICOM standard, provide a standard means to organize eddy current test parameters and results. The eddy current examination results may be displayed or analyzed on any device that conforms to the standard. Personnel wishing to view any eddy current examination data stored according to Practice E2339 may use this document to help them decode and display the data contained in the DICONDE compliant inspection record.1.1 This practice covers the interoperability of eddy current imaging and data acquisition equipment by specifying the image data transfer and archival storage in commonly accepted terms. This document is intended to be used in conjunction with Practice E2339 on Digital Imaging and Communication in Nondestructive Evaluation (DICONDE). Practice E2339 defines an industrial adaptation of NEMA PS3 / ISO 12052, an international standard for image data acquisition, review, storage, and archival storage. The goal of Practice E2339, commonly referred to as DICONDE, is to provide a standard that facilitates the display and analysis of NDE results on any system conforming to the DICONDE standard. Toward that end, Practice E2339 provides a data dictionary and a set of information modules that are applicable to all NDE modalities. This practice supplements Practice E2339 by providing information object definitions, information modules, and a data dictionary that are specific to eddy current test methods.1.2 This practice has been developed to overcome the issues that arise when analyzing or archiving data from eddy current test equipment using proprietary data transfer and storage methods. As digital technologies evolve, data must remain decipherable through the use of open, industry-wide methods for data transfer and archival storage. This practice defines a method where all the eddy current technique parameters and inspection data are communicated and stored in a standard manner regardless of changes in digital technology.1.3 This practice does not specify:1.3.1 A testing or validation procedure to assess an implementation's conformance to the standard,1.3.2 The implementation details of any features of the standard on a device claiming conformance, or1.3.3 The overall set of features and functions to be expected from a system implemented by integrating a group of devices each claiming DICONDE conformance.1.4 Units—Although this practice contains no values that require units, it does describe methods to store and communicate data that do require units to be properly interpreted. The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

5.1 Particle size and shape are important in predicting the performance of catalytic materials. They influence the bulk density of the final product and thereby the effectiveness of performance.5.2 Establishing a verification reference for the analyzer that is commercially available and dimensionally reliable to close tolerances enables different analyzers to be easily checked to equivalent standards.5.3 This practice may also be followed to analyze catalytic materials for quality manufacturing purposes. Sections 9 and 10 instruct on sample count determination as well as sampling recommendations. Test Method D6299 may be utilized to monitor performance of the analyzer in measuring the size and shape of catalytic materials.1.1 This practice covers the calibration and verification of Dynamic Imaging Analyzers (analyzers) using catalytic and non-catalytic reference materials. The measurement range of analyzers covers from 500 µm to 20 000 µm.1.2 This practice may also be used to analyze catalytic materials once the analyzer has been calibrated and verified.1.3 Units—The values stated in SI units are to be regarded as standard; however, English and mesh units are also acceptable with conversions provided in Appendix X3.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
74 条记录,每页 15 条,当前第 1 / 5 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页