微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读
ASTM A368-95a(2019) Standard Specification for Stainless Steel Wire Strand Active 发布日期 :  1970-01-01 实施日期 : 

This specification covers the standard for stainless steel wire strand composed of a multiplicity of round wires and suitable for use as guy wires, overhead ground wires, and similar purposes. Stranding shall be sufficiently close to ensure no appreciable reduction in diameter when stressed to the specified strength. Several types of steel are covered like Type 302, 304, 305, 316, 316Cb, or 316Ti and shall conform to the required chemical composition values in carbon, manganese, phosphorus, sulfur, silicon, chromium, nickel, molybdenum, and nitrogen. The tensile strength, based upon the nominal strand diameter and the number of wires in each strand, shall conform to the minimum values in breaking strength. The individual wires of the completed strand shall not fracture when wrapped in a close helix of at least two turns upon itself as a mandrel.1.1 This specification covers stainless steel wire strand composed of a multiplicity of round wires and suitable for use as guy wires, overhead ground wires, and similar purposes.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 Seven-wire steel strand is used in pre-tensioned and post-tensioned concrete construction.4.2 0.600 in. [15.24 mm] diameter, Grade 270 seven-wire steel strand is used to make prestressed ground anchors which are often bonded to cement grout.4.3 Manufacturing processes, subsequent handling, and storage conditions may influence the strand bond.4.4 The primary use of this test method is to establish the relative bond strength of 0.600 in. [15.24 mm] seven-wire steel strand.4.5 The relative bond strength is determined by recording the pullout force at a certain displacement of the strand.AbstractThis test method deals with the standard procedures for establishing the relative bond strength of Grade 270 prestressing steel strands of specified diameter in cement grout as used in prestressed ground anchors for evaluating the effects of manufacturing practices on bond strength. The bond strength values obtained shall not be used to design the bond strength of ground anchors that depend on field conditions. This test method is not intended to be used as a bond test for pretensioned concrete applications. The test specimen shall be cut from standard production coils and shall not be wiped or cleaned. Pull test shall be made in accordance with the method.1.1 This test method describes procedures to establish the relative bond strength of 0.600 in. [15.24 mm] diameter, Grade 270 [1860] seven-wire steel strand in cement grout as used in prestressed ground anchors for the purpose of evaluating the effects of manufacturing practices on bond strength.1.2 The bond strength values obtained are not intended to be used to design the bond length of ground anchors that depend on field conditions.1.3 This test method is not intended to be used as a bond test for prestressed concrete applications.1.4 The values stated in either inch-pound or SI units are to be regarded as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
CAN/CSA-G12-92 (R2003) Zinc-Coated Steel Wire Strand 现行 发布日期 :  1970-01-01 实施日期 : 

1. Scope 1.1 This Standard describes zinc-coated steel wire strand suitable for use as guys, suspension strand, span wires, and overhead ground wire strand. Overhead ground wire strand for electric power transmission is produced free of wire joints.

定价: 364元 / 折扣价: 310

在线阅读 收 藏
ASTM A475-22 Standard Specification for Metallic-Coated Steel Wire Strand Active 发布日期 :  1970-01-01 实施日期 : 

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
AS 1504-1983 Fibre rope - Three-strand, hawser laid 现行 发布日期 :  1970-01-01 实施日期 : 

定价: 689元 / 折扣价: 586

在线阅读 收 藏

This specification deals with the standard types and grade requirements of seven-wire, uncoated steel strands for use in the construction of pre-tensioned and post-tensioned pre-stressed concrete. The two types of strand are low-relaxation and stress-relieved (normal relaxation). The base metal shall be made of carbon steel and shall undergo stranding and continuous thermal and mechanical treatment. Mechanical testing methods shall be performed to determine the breaking strength, yield strength, elongation, and stress relaxation properties wherein the strand shall conform to the required mechanical attributes of the product. Final products shall be furnished on reels or in reelless packs for packaging and marked with two strong tags for identification. The requirements specified herein shall also be applicable for pre-stressed ground anchor construction.1.1 This specification covers two grades of low-relaxation, seven-wire steel strand for use in prestressed concrete construction. Grade 250 [1725] and Grade 270 [1860] have minimum tensile strengths of 250 ksi [1725 MPa] and 270 ksi [1860 MPa], respectively, based on the nominal area of the strand.1.2 A supplementary requirement (S1) is provided for use where bond strength testing of 0.600-in. [15.24-mm] diameter Grade 270 [1860] strand for applications in prestressed ground anchors is required by the purchaser. The supplementary requirement applies only when specified in the purchase order.1.3 The text of this specification contains notes or footnotes, or both, that provide explanatory material. Such notes and footnotes do not contain any mandatory information.1.4 This specification is applicable for orders in either inch-pound units (as Specification A416) or in SI units (as Specification A416M).1.5 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the specification.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
ASTM A460-11(2021) Standard Specification for Copper-Clad Steel Wire Strand Active 发布日期 :  1970-01-01 实施日期 : 

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

This specification covers minimum performance standards and test requirements for gap-filling construction adhesives for field-gluing plywood to lumber framing for floor systems. The adhesive shall conform to the strength and durability properties prescribed. The different methods for specimen's preparation are presented in details. The shear strength, gap-filling effect on strength, and durability shall be tested to meet the requirements prescribed.1.1 This specification covers minimum performance standards and test requirements for gap-filling construction adhesives for bonding wood structural panels consisting of plywood or oriented strand board (OSB) to wood based floor system framing, particularly dimension lumber or wood I-joists, at the construction site.1.2 This specification provides a basis for ensuring the quality of the adhesives and is not intended as an application specification.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 The following precautionary caveat pertains only to the test method portion, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 702元 / 折扣价: 597 加购物车

在线阅读 收 藏

定价: 260元 / 折扣价: 221 加购物车

在线阅读 收 藏
53 条记录,每页 15 条,当前第 1 / 4 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页