微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

This specification covers the minimum performance and material requirements for resilient connectors used for connections between reinforced concrete tanks used for septic effluent treatment/detention. All materials shall be suitable for use in sanitary sewage applications. Each connector design shall be tested in accordance with the requirements specified. The following test methods shall be performed: straight alignment; axial deflection; and shear loading.1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between reinforced concrete tanks used for septic effluent treatment/detention, including those referenced in Specifications C913 and C1227.1.1.1 These connectors are designed to eliminate leakage between the pipe(s) and tank.1.2 A complete metric companion to Specification C1644 has been developed—C1644M; therefore, no metric equivalents are presented in this specification.NOTE 1: This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 5 psi (11.5 ft) without leakage when tested in accordance with Section 7. Infiltration or exfiltration quantities for an installed system are dependent upon many factors other than the connectors between tanks and pipes, and allowable quantities must be covered by other specifications and suitable testing of the installed pipe and system.1.3 The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

3.1 The use of this practice for the emergency joining of booms will not guarantee the effective performance of the joined boom sections, since each boom design and the environmental conditions of each incident govern the overall performance.3.2 Historically, different types of end connectors have been produced. This practice addresses the operational need to connect different types, during spill incidents. (Warning—Use of this practice with similar or different sizes of boom may cause the transmission of unwanted loading such as, tension loading and bending moments on certain boom parts resulting in possible premature failure of the containment system.)3.3 There are a wide range of boom connector configurations presently in use. These connectors were based upon some or all of the following design criteria:3.3.1 Connect and transfer tensile loads between boom sections,3.3.2 Minimize oil leakage between boom sections,3.3.3 Be easily connectable in the presence of dirt, oil or ice, or a combination thereof,3.3.4 Be quickly and easily connected and disconnected, in and out of the water,3.3.5 Maintain boom performance (freeboard, heave response, conformance, stability, and so forth),3.3.6 Be unaffected by temperature extremes,3.3.7 Have no protruding parts that could snag, injure, or puncture,3.3.8 Be light weight and buoyant,3.3.9 Be operatively symmetrical,3.3.10 Require no special tools for installation or removal,3.3.11 Require no loose parts for connection,3.3.12 Extend to the full height and draft of the boom,3.3.13 Resist distortion (that is, winding boom on a reel), and3.3.14 Be inherently safe to personnel.1.1 This practice provides a standard practice for the joining of oil spill containment boom connectors in emergencies.1.2 The use of this connection method may adversely affect the total tensile strength of the connected booms.1.3 These criteria are intended to define mating requirements that will allow the emergency or occasional connection of unlike connectors.1.4 This practice is not intended to replace Specification F962.1.5 This practice does not address the compatibility of spill control equipment with spill products. It is the user's responsibility to ensure that any equipment selected is compatible with the anticipated spilled material.1.6 There is no guarantee that all of the connectors in use today can accept the holes spaced as required without interfering with existing bolt holes or other connector features.1.7 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. See Note 5 in Fig. 1—dimensions A and B are critical.FIG. 1 Side View of a Typical Connector1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific precautionary statement, see 3.2.1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 618元 / 折扣价: 526 加购物车

在线阅读 收 藏
A112.18.6-09/CAN/CSA-B125.6-09 Flexible water connectors 现行 发布日期 :  1970-01-01 实施日期 : 

定价: 774元 / 折扣价: 658

在线阅读 收 藏
ASTM E1129/E1129M-19 Standard Specification for Thermocouple Connectors Active 发布日期 :  1970-01-01 实施日期 : 

4.1 The widespread use of thermocouple connectors requires standardization of mating dimensions and performance characteristics.4.2 This specification describes standardized thermocouple connector dimensions and capabilities and includes test procedures suitable for evaluating the performance of a particular specimen or design. The tests described are not intended for routine inspection or rapid testing of large groups of connectors or for quality control purposes.AbstractThis specification covers separable single-circuit thermocouple connectors with two round pins. The widespread use of thermocouple connectors requires standardization of mating dimensions and performance characteristics. Connectors shall be constructed as either plugs or jacks, and these two forms shall be designed to connect with each other. Contact resistance test, thermal gradient test, and insulation resistance test shall be performed to meet the requirements prescribed.1.1 This specification covers separable single-circuit thermocouple connectors with two round pins. Connectors covered by this specification must be rated for continuous use to at least 300 °F (150 °C), but they may optionally be rated to a higher temperature.1.2 This specification does not cover multiple-circuit connectors, multi-pin connectors, miniature connectors, or connectors intended primarily for panel mounting. High temperature connectors (for example, those designed for continuous use at temperatures above approximately 500 °F (260 °C)) are not intended to be covered by this specification.1.3 The values stated in either inch-pound units or SI units are to be regarded separately as standard. The values stated in brackets are not conversions to the values they succeed and therefore shall be used independently of the preceding values. The values given in parentheses are conversions of the values they succeed. Combining values from the two systems may result in non-conformance with the standard.1.4 The following precautionary statement pertains only to the test methods portion, Section 9, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 2821元 / 折扣价: 2398

在线阅读 收 藏

This specification establishes the requirements for copper alloy strips for use in the manufacture of electrical connectors or spring contacts produced from one of the following Copper Alloy UNS Nos.: C14530, C15100, C15500, C17000, C17200, C17410, C17450, C17460, C17500, C17510, C19010, C19025, C19210, C19400, C19500, C19700, C23000, C26000, C40810, C40850, C40860, C42200, C42500, C42520, C42600, C50580, C50780, C51000, C51080, C51100, C51180, C51980, C52100, C52180, C52480, C63800, C65400, C68800, C70250, C70260, C70265, C75200, and C76200. The material for manufacture shall be a cast bar, slab, cake, billet, or other form of such composition as to be suitable for processing by either hot- or cold-working to produce the products prescribed in this specification. Products shall be finished by hot working, cold working, annealing, or heat treatment as may be necessary to meet mechanical property requirements, which include tensile strength, yield strength, and elongation. Tempers shall be available in the annealed, rolled, or mill hardened conditions. Products shall also adhere to tolerances as to dimension such as thickness, width, length, straightness, and mass.1.1 This specification establishes the requirements for copper alloy strip for use in the manufacture of electrical connectors or spring contacts produced from one of the following Copper Alloy UNS Nos.:2 C14530, C15100, C15500, C17000, C17200, C17410, C17450, C17460, C17500, C17510, C19002, C19010, C19015, C19025, C19210, C19400, C19500, C19700, C23000, C26000, C40810, C40850, C40860, C42200, C42500, C42520, C42600, C50580, C50780, C51000, C51080, C51100, C51180, C51980, C52100, C52180, C52480, C63800, C64725, C65400, C68800, C70250, C70260, C70265, C70310, C70350, C75200, and C76200.1.2 The requirements for the other copper alloys such as copper-nickel-tin spinodal, UNS C72650, C72700, and C72900, shall be as prescribed in the current edition of Specification B740.1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

This PDF includes GI #2. 1. Scope This Standard applies to (a) electrode receptacles and fittings for mounting gas tubes intended for indoor and outdoor applications operating at voltages of 15 000 V and less but not exceeding 7 500 V to ground for

定价: 455元 / 折扣价: 387

在线阅读 收 藏
C22.2 NO. 2459-08 Insulated multi-pole splicing wire connectors 现行 发布日期 :  1970-01-01 实施日期 : 

定价: 3367元 / 折扣价: 2862

在线阅读 收 藏

This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems. These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral. Resilient materials for connectors, filler rings, and mechanical devices shall be tested, and shall conform to the specified values chemical resistance, tensile strength, elongation hardness, accelerated oven-aging, compression set, water absorption, ozone resistance, low-temperature brittle point, and tear resistance. The design of the connector and the pipe stubs are detailed.1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C478/C478M and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems.1.1.1 These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral.1.2 The values stated in inch pound or SI units are to be regarded separately as standard. The SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.NOTE 1: This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 6 psi (14 ft) [41 kPa (4.3 m)] without leakage when tested in accordance with Section 7. Infiltration quantities for an installed system are dependent upon many factors other than the connections between storm sewer structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.NOTE 2: For installations that exceed 6 psi (14 ft) [41 kPa (4.3 m)], the user is cautioned to verify the amount of hydrostatic head pressure the connector will experience. If the total pressure applied to the connector exceeds the 6 psi [41 kPa] limits of the specification, the user is advised to contact the connector manufacturer for alternative methods of connecting the pipe, or applicable alternative standards.1.3 The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific warning statement, see 7.2.4.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems. These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral. Resilient materials for connectors, filler rings, and mechanical devices shall be tested, and shall conform to the specified values chemical resistance, tensile strength, elongation hardness, accelerated oven-aging, compression set, water absorption, ozone resistance, low-temperature brittle point, and tear resistance. The design of the connector and the pipe stubs are detailed.1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems.1.1.1 These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral.1.2 This specification is the SI companion to C1478.NOTE 1: This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 41 kPa (4.3 m) without leakage when tested in accordance with Section 7. Infiltration quantities for an installed system are dependent upon many factors other than the connections between storm sewer structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.NOTE 2: For installations that exceed 41 kPa (4.3 m), the user is cautioned to verify the amount of hydrostatic head pressure the connector will experience. If the total pressure applied to the connector exceeds the 41 kPa limits of the specification, the user is advised to contact the connector manufacturer for alternative methods of connecting the pipe, or applicable alternative standards.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific warning statement, see 7.2.4.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

This PDF includes GI #2 and #3. 1. Scope 1.1 This Standard applies to plugs, receptacles, and connectors for communication systems intended to electrically terminate (a) communication cords; (b) communication cord sets; or (c) equipment that is c

定价: 455元 / 折扣价: 387

在线阅读 收 藏

定价: 546元 / 折扣价: 465

在线阅读 收 藏

Scope Details test and examination criteria for gas appliance connectors limited to a maximum nominal length of 6 feet (1.83m). Such connectors are suitable for connecting gas-fired appliances to fixed gas supply lines containing natural, manufactured

定价: 683元 / 折扣价: 581

在线阅读 收 藏

This specification covers the design, material, and minimum performance requirements for resilient connectors used to provide a positive seal between the pipe and manholes or other structures subjected to internal and external hydrostatic pressures less than 10.8 psi [74 KPa]. Testing under this specification is limited to hydrostatic pressures and conducted in a laboratory as a proof of design certification. Resilient materials for connectors and filler rings shall be manufactured from natural or synthetic rubber, shall display no fracture at -40 ºF [-40 ºC], and shall meet a minimum tear resistance of 200 lbf/in [34 kN/m] when tested. Expansion rings, tension bands, and take-up devices used for mechanically compressing the resilient portion of the connector against the pipe, manhole or wastewater structure shall be made from a material or materials in combination that will ensure durability, strength, resistance to corrosion, and continued resistance to leakage. Bolts, nuts, and other threaded items used with joining systems shall be zinc coated by one of the following processes: hot-dip process, electroplating process, or mechanical process. The same processes shall be used for zinc coating of other hardware items used with coupling bands.This specification also covers requirements for basis of acceptance, test methods, and product marking.1.1 This specification covers the design, material, and minimum performance requirements of resilient connectors used for connections between reinforced concrete structures conforming to Specifications C478 and C913 to corrugated steel drainage pipe conforming to Specifications A760 or A762.1.1.1 These connectors are designed to provide a positive seal between the pipe and manholes or other structures subjected to internal and external hydrostatic pressures less than 10.8 psi [74 KPa].1.1.2 Testing under this standard is limited to hydrostatic pressures. Alternate air and vacuum pressure testing involve unique testing protocols and are not addressed under this standard.1.1.3 Testing under this standard is conducted in a laboratory as a proof of design certification. Actual field performance testing would be accomplished and accepted under individual project performance standards or pipeline acceptance criteria, which is outside the scope of this standard.NOTE 1: Infiltration or exfiltration quantities for an installed system are dependent upon many factors other than the connections between manhole structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text the SI units are shown in brackets. The values stated in each system may not be exact equivalents: therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.3 The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific precaution statement, see 7.2.4.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

1 Scope This part of ISO 5841 specifies a connector assembly to be used to connect implantable pacemaker leads to implantable pacemaker pulse generators. Essential dimensions and performance requirements related to connector fit are specified, togethe

定价: 455元 / 折扣价: 387

在线阅读 收 藏
49 条记录,每页 15 条,当前第 2 / 4 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页