5.1 This practice provides criteria for products used to measure particulate matter present in a sample of aviation turbine fuel. The objective is to verify that filters, support pads, and field monitors fall within the acceptable ranges that are established by this practice.1.1 This practice determines suitability of products used for measuring particulate contamination in aviation turbine fuel when using Test Methods D5452 and D2276.1.2 There are two major parts of this practice. The first is for evaluation of the cellulose acetate butyrate field monitors that are used in combination with the filters and the filter support pads. The second part is for evaluation of the filter when used with an appropriate cellulose acetate butyrate field monitor.1.3 Units—The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
定价: 590元 加购物车
This part of IEC 62271 is applicable to three-phase AC high-voltage generator circuit-breakers, hereafter called generator circuit-breakers, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 kV and up to 38 kV. It is applicable to generator circuit-breakers that are installed between the generator and the transformer terminals. Requirements relative to generator circuit-breakers intended for use with generators and… read more transformers rated 10 MVA or more are covered specifically. Generator circuits rated less than 10 MVA and pumped-storage installations are considered special applications, and their requirements are not completely covered by this document. This document is also applicable to the operating mechanisms of generator circuit-breakers and to their auxiliary equipment. read less
As part of the Dual Logo Agreement between IEEE and IEC, this standard is denoted IEC/IEEE 62271-37-082. This standard provides methods for the measurement of sound pressure level produced by outdoor alternating current circuit-breakers in a free-field environment. These methods may also be used indoors or in restricted field, provided that precautions are observed in the measurement and interpretation of the results.
This part of International Standard 62271 provides methods for the measurement of sound pressure level produced by outdoor alternating current circuit-breakers in a free-field environment. These methods may also be used indoors or in restricted field, provided that precautions are observed in the measurement and interpretation of the results.