This standard sets forth uniform methods of measurement of radio noise emitted from low voltage electrical and electronic equipment in the frequency range of 10 kHz to 1 GHz. Methods for the measurement of radiated and power-line conducted radio noise are covered and may be applied to any such equipment unless otherwise specified by individual equipment requirements. These methods apply to the measurement of individual components, units, or systems comprising components and units. Additional… read more methods may be added to this standard to fulfill future requirements as needed. Unless specifically called out, this standard is not intended for certification or approval of avionic equipment. The method for validation of test sites such as open area sites and absorber-lined chambers for frequencies in the range of 30 MHz-1000 MHz is contained in this standard. read less

定价: 53元 / 折扣价: 46

在线阅读 收 藏

This standard specifies consensus standard methods, instrumentation, and facilities for measurement of radio-frequency (RF) signals and noise emitted from electrical and electronic devices in the frequency range of 9 kHz to 40 GHz, as usable, for example, for compliance testing to U.S. (47CFR15) and Canada (ICES-003) regulatory requirements.1 It does not include generic or product-specific emission limits. Where possible, the specifications herein are harmonized with other national and… read more international standards used for similar purposes. read less

定价: 203元 / 折扣价: 173

在线阅读 收 藏

This guide shows the basis for the acceptability criterion of k4 dB for the site attenuation measurements required in ANSI C63.4-1988.

定价: 88元 / 折扣价: 75

在线阅读 收 藏

This standard provides recommended test methods and limits for assuring the radio frequency (RF) immunity of office equipment to general use transmitters with transmitter power up to 8 watts.

定价: 141元 / 折扣价: 120

在线阅读 收 藏

ANSI N13.30-1996, American National Standard Performance Criteria for Radiobioassay

定价: 174元 / 折扣价: 148

在线阅读 收 藏

This standard applies to wide-bandgap semiconductor radiation detectors, such as cadmium telluride (CdTe), cadmium-zinc-telluride (CdZnTe, referred to herein as CZT), and mercuric iodide (HgI2) used in the detection and measurement of ionizing radiation at room temperature; gamma rays, X-rays, and charged particles are covered. The measurement procedures described herein apply primarily to detector elements having planar, hemispherical, or other geometries in which charge carriers of both… read more polarities contribute to the output signal. When the devices are an integral part of a system, it may not be possible for a user to make tests on the detector alone. In this instance, tests on the detector element must be established by mutual agreement between the manufacturer and the user. read less

定价: 102元 / 折扣价: 87

在线阅读 收 藏

This standard describes minimum performance requirements and test methods for evaluating the performance of alarming personal radiation detectors (PRDs) for homeland security applications. PRDs are pocket-sized battery-powered alarming electronic instruments that are worn on the body and used to detect photon-emitting, and optionally neutron-emitting, radioactive materials. PRDs have user-readable displays related to the intensity of radiation, but they are distinct from, and typically more… read more sensitive than, electronic personal dosimeters, which are designed to measure the dose equivalent to workers occupationally exposed to radiation. The performance criteria contained in this standard are meant to provide the means for verifying the capability of the PRDs to reliably detect changes above background levels of ionizing radiation fields and alert the user to these changes. This standard also specifies the requirements and test methods for environmental, electromagnetic, and mechanical conditions that may affect the ability of the PRDs to function properly. This standard does not apply to spectroscopic PRDs that have the ability to identity radionuclides. The ANSI N42.48 standard [B12] covers spectroscopic PRDs.1 This standard does not apply to instruments that are primarily intended to provide a measurement of dose-equivalent, personal dose-equivalent, or ambient dose-equivalent rate. However, if the manufacturers of PRDs that provide an indication of personal dose-equivalent rate (expressed in units of mrem/h or μSv/h) claim that the PRD may be used for personal protection, then the PRD shall comply with the applicable radiological requirements described in ANSI N42.20 [B17] (i.e., accuracy, energy, and angle response tests). read less

定价: 128元 / 折扣价: 109

在线阅读 收 藏

The purpose of this standard is to specify performance criteria and type-test methods used to evaluate portable radiation detection instruments. These instruments are used for detection of photon emitting radioactive materials and photon exposure rates. Instruments are used for the purposes of detection, interdiction and prevention. Instruments may include alarms to indicate an increase in exposure rate. This standard does not apply to instruments that are primarily intended to provide a… read more measurement of dose equivalent rate. In a departure from other DHS-related ANSI N42 instruments standards, some issues of Radiological/Nuclear initial response (R/N initial response) are discussed. A tactical description of R/N initial response is provided in this revised standard in Annex H and is generally linked to related R/N initial response instrumentation situations in ANSI N42.32, ANSI N42.34, ANSI N42.35, ANSI N42.38, ANSI N42.43, ANSI N42.53, and directly linked to ANSI N42.49A. This direct link is from a portable instrument with low exposure rate range to a portable instrument of a much higher exposure rate range. This instrument range change may be necessary in some R/N initial response situations. read less

定价: 106元 / 折扣价: 91

在线阅读 收 藏

This standard specifies general requirements and test procedures, radiation response requirements, and electrical, mechanical, and environmental requirements. Successful completion of the tests described in this standard should not be construed as an ability to successfully identify all isotopes in all environments.

定价: 65元 / 折扣价: 56

在线阅读 收 藏

This standard specifies general, radiological, climatic, electromagnetic, and mechanical requirements, and associated test methods for handheld radionuclide identification devices (RIDs). Successful completion of the tests described in this standard should not be construed as an ability to identify all radionuclides in all environments.

定价: 83元 / 折扣价: 71

在线阅读 收 藏

This standard establishes the performance requirements and provides the testing and evaluation criteria for installed radiation portal monitors (RPMs) that detect photon- and neutron-emitting radioactive substances by monitoring people, packages, containers, and vehicles. Performance requirements for portal monitors with radionuclide identification capabilities are addressed by the ANSI N42.38 standard [B19]. Performance requirements for mobile and transportable systems are addressed by the… read more ANSI N42.43 standard [B20]. read less

定价: 106元 / 折扣价: 91

在线阅读 收 藏

This standard applies to security screening systems that utilize x-ray or gamma radiation and are used to inspect people who are not inside vehicles, containers, or enclosures. Specifically, this standard applies to systems used to detect objects carried on or within the body of the individual being exposed. The following types of systems are included in the scope of this standard: ⎯ Systems designated as fixed, portal, re-locatable, transportable, mobile, or gantry. ⎯ Systems employing… read more detection of primary radiation (transmission systems), or scatter radiation (backscatter systems), or a combination of both. ⎯ Systems that are primarily imaging but that also may have complementary features such as material discrimination, or automatic active or passive threat alerts. This standard will not address how to test these complementary features. read less

定价: 124元 / 折扣价: 106

在线阅读 收 藏

This standard describes design and performance requirements along with testing methods for evaluating radiation detection instruments that are pocket-sized and worn on the body for the purpose of rapid detection and identification of radioactive materials. The performance requirements contained in this standard are meant to provide a means for verifying the capability of these instruments to reliably detect changes above background levels of radiation, notify the user to these changes, and… read more provide a means to determine if the alarm was caused by a radionuclide of interest that may require further evaluation. These devices are not primarily intended to provide a measurement of dose-equivalent rate. However, their indication can provide an approximate value of exposure rate that should be reasonably accurate. They are also not meant to provide radionuclide identification at the same level as radionuclide identification detectors defined in ANSI N42.34.1 Successful completion of the tests described in this standard should not be construed as an ability to identify all radionuclides in all environments. read less

定价: 72元 / 折扣价: 62

在线阅读 收 藏

This standard specifies minimum performance requirements and performance testing requirements for instruments designed to measure radon progeny in air. Radon progeny has historically been characterized in terms of its potential alpha energy concentration (PAEC), expressed in either units of working level (WL)

定价: 74元 / 折扣价: 63

在线阅读 收 藏

This standard specifies the basic performance requirements for backpack-based radiation-detection systems (BRDs) used in homeland security applications. BRDs consist of a body worn detection assembly that may be carried in a backpack, vest, or shoulder bag, and a wired or wireless user interface/display. BRDs shall detect gamma radiation and may include neutron detection and/or the identification of gamma-ray emitting radionuclides.

定价: 84元 / 折扣价: 72

在线阅读 收 藏