微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 260元 / 折扣价: 221

在线阅读 收 藏
AS 1680.2.2-1994 Interior lighting - Office and screen-based tasks 被代替 发布日期 :  1994-01-17 实施日期 : 

定价: 689元 / 折扣价: 586 加购物车

在线阅读 收 藏
AS 1680.2.3-1994 Interior lighting - Educational and training facilities 被代替 发布日期 :  1994-01-17 实施日期 : 

定价: 605元 / 折扣价: 515 加购物车

在线阅读 收 藏

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏
AS 1680.2.1-1993 Interior lighting - Circulation spaces and other general areas 被代替 发布日期 :  1993-06-14 实施日期 : 

定价: 345元 / 折扣价: 294 加购物车

在线阅读 收 藏

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏

定价: 975元 / 折扣价: 829 加购物车

在线阅读 收 藏

定价: 481元 / 折扣价: 409 加购物车

在线阅读 收 藏
AS 1680.1-1990 Interior lighting General principles and recommendations 现行 发布日期 :  1990-07-16 实施日期 : 

定价: 1515元 / 折扣价: 1288 加购物车

在线阅读 收 藏

4.1 A waterproofing membrane should maintain its watertight integrity for the life of the building in a continuously or intermittently moist environment and may be subject to continuous or intermittent hydrostatic pressure. It should resist chemicals that can harm the membrane and root growth. This guide lists minimum performance attributes required of waterproofing membranes applied to below-grade walls. Products not previously used as waterproofing membrane materials require additional tests beyond the scope of this guide. This guide is not intended for use on in-service waterproofing materials. Waterproofing membranes and other components should conform to ASTM product standards, if available.4.2 Limitations—Prior to use and in service, waterproofing may be exposed to a variety of conditions so no one test will provide evaluations related to performance for all exposures. Neither will all tests be necessary in all evaluations for specific exposures.1.1 This guide lists test methods intended to establish a minimum level of acceptable performance attributes for reinforced or laminated waterproofing membranes applied to below-grade walls.1.2 This guide does not include cementitious, integral, or bentonite waterproofing systems.1.3 This guide does not include membranes applied under slabs on grade or on suspended slabs below grade or applied to soil retaining systems, water containment structures, or tunnels.1.4 It is not possible to establish a precise correlation between laboratory tests on waterproofing membranes and performance attributes after installation due to variations in chemicals in the soil, design, material, and installation.1.5 The values stated in either inch-pound or SI units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

3.1 The maximum length and minimum diameter of the pipe shall be determined by the capacity of the blast equipment used.3.2 This guide is recommended for removing mill scale, rust scale, paints, zincs, and oxides.1.1 This guide covers metallic abrasive blasting to descale the interior of carbon steel pipe.1.2 This guide is recommended for use in conjunction with an abrasive reclamation system.1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers the requirements, test methods, and materials for 4 to 36-in. diameter poly(vinyl chloride) (PVC) corrugated pipes, joints, and fittings that consist of an outer corrugated wall fused to a smooth inner wall, and are suitable for underground use in nonpressure applications for sanitary sewers, storm sewers, and perforated and unperforated pipes for subdrainage. When evaluated by the test procedures enumerated herein, the products shall conform to dimensional and performance requirements as specified for pipe stiffness, flattening resistance, impact strength, extrusion quality, heat reversion, bond strength, and joint tightness.1.1 This specification covers requirements, test methods, and materials for 4 to 48 in. diameter poly(vinyl chloride) (PVC) corrugated pipe with a smooth interior. This profile wall pipe consists of an outer corrugated wall fused to a smooth inner wall providing pipe stiffness levels of 46 psi and 115 psi. Joints and fittings are included in this specification.1.2 The requirements of this specification are intended to provide pipe and fittings suitable for underground use in nonpressure applications for sanitary sewers, storm sewers, and perforated and unperforated pipes for subdrainage.NOTE 1: Industrial waste disposal lines should be installed only with the specific approval of the cognizant code authority, since chemicals not commonly found in drains and sewers and temperatures in excess of 140 °F (60 °C) may be encountered.1.3 Pipe and fittings produced to this specification shall be installed in accordance with Practice D2321.NOTE 2: For perforated pipe applications, the size of the embedment zone and permeability of the embedment material are important to the system's ability to provide the desired level of infiltration or exfiltration. The gradation of the embedment material must be compatible with the perforation slot size to avoid backfill migration into the pipe.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.5 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

1. Scope Section A - Transformers for Luminous-Tube Signs A1.1 This section applies to transformers for luminous-tube signs of portable and stationary types, for potentials up to and includ ing 600 volts low-potential, and l5,000 volts open-circuit

定价: 546元 / 折扣价: 465

在线阅读 收 藏

1.1 This test method describes a procedure for measuring the interior pore volume and the apparent pore diameter distribution of porous poly(vinyl chloride) resins. The measurements are made by forcing mercury under increasing pressure through a graduated penetrometer into the open pores of the resin samples. The volume of mercury forced into the pores is defined from the change of the mercury volume in the penetrometer; the apparent pore diameter distribution can be defined from incremental volume changes with increasing pressure. 1.2 Warning-This standard includes the use of an OSHA-designated hazardous chemical (Mercury). For specific hazard information and guidance relative to use, consult the health and safety documents provided by the supplier, for example, the material safety data sheet. 1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note 1-There are no ISO standards covering the primary subject matter of this test method.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

4.1 Each abuse/impact property of abuse resistant wall panels is divided into three classification levels. The three levels of classification are: Level I, Level II, and Level III, with Level I representing the lowest rating for any given property. The test methods specified are utilized to establish the abuse-resistance classification of an abuse resistant wall panel. Each classification level requires a minimum overall specified performance. Any classified abuse resistant wall panel can be used at a classification level which is rated lower than the highest level qualified.1.1 This standard establishes classifications of abuse resistance based on the abrasion resistance and impact resistance performance of nondecorated interior gypsum panel products and fiber-reinforced cement panels (abuse resistant wall panels).1.1.1 This standard is a method of classifying gypsum panel product performance and is not intended to classify systems for abuse resistance.1.2 The values stated in inch-pound and SI (metric) units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system shall be used independent of the other. Values from the two systems shall not be combined.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏
36 条记录,每页 15 条,当前第 1 / 3 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页