
【国外标准】 Standard Practice for Visible Penetrant Testing Using the Water-Washable Process
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Liquid penetrant examination methods indicate the presence, location, and, to a limited extent, the nature and magnitude of the detected discontinuities. This practice is normally used for production examination of large volumes of parts or structures, where emphasis is on productivity. This practice offers a wide latitude in applicability when extensive and controlled conditions are available.1.1 This practice describes procedures for visible liquid penetrant examination utilizing the water-washable process. It is a nondestructive practice for detecting discontinuities that are open to the surface such as cracks, seams, laps, cold shuts, laminations, isolated porosity, through leaks or lack of fusion and is applicable to in-process, final, and maintenance examination. This practice can be effectively used in the examination of nonporous, metallic materials, both ferrous and nonferrous, and of nonmetallic materials such as glazed or fully densified ceramics, and certain nonporous plastics, and glass.1.2 This practice also provides the following references:1.2.1 A reference by which visible penetrant examination procedures using the water-washable process can be reviewed to ascertain their applicability and completeness.1.2.2 For use in the preparation of process specifications dealing with the visible, water-washable liquid penetrant examination of materials and parts. Agreement between the user and the supplier regarding specific techniques is strongly recommended.1.2.3 For use in the organization of the facilities and personnel concerned with the liquid penetrant examination.1.3 This practice does not indicate or suggest criteria for evaluation of the indications obtained. It should be noted, however, that after indications have been produced, they must be interpreted or classified and then evaluated. For this purpose there must be a separate code, specification, or a specific agreement to define the type, size, location, and orientation of indications considered acceptable, and those considered unacceptable.1.3.1 The user is encouraged to use materials and processing parameters necessary to detect conditions of a type or severity which could affect the evaluation of the product.1.4 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.5 Basis of Application—There are areas in this practice that may require agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization. These areas are identified as follows:1.5.1 Penetrant type, method and sensitivity,1.5.2 Accept/reject criteria,1.5.3 Personnel qualification requirements,1.5.4 Grit blasting,1.5.5 Etching,1.5.6 Indication/discontinuity sizing,1.5.7 Total processing time, and1.5.8 Marking of parts.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E1418-21
标准名称:
Standard Practice for Visible Penetrant Testing Using the Water-Washable Process
英文名称:
Standard Practice for Visible Penetrant Testing Using the Water-Washable Process标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 4276.21-2005 Water microbiology Examination for coliforms and Escherichia coli - Determination of most probable number (MPN) using enzyme hydrolysable substrates
- AS/NZS 1635.21.1:1995 Methods of test for pressure-sensitive adhesive tape - Mending stability
- AS/NZS 3200.2.21:1994 Approval and test specification - Medical electrical equipment Particular requirements for safety - Infant radiant warmers
- AS/NZS 3200.2.21:1994/Amdt 1:1998 Approval and test specification - Medical electrical equipment - Particular requirements for safety - Infant radiant warmers
- AS/NZS 3350.2.21:1999/Amdt 1:2001 Safety of household and similar electrical appliances - Particular requirements - Storage water heaters
- AS/NZS 3350.2.21:1999/Amdt 3:2004 Safety of household and similar electrical appliances Particular requirements - Storage Water Heaters
- AS/NZS 3350.2.21:1999/Amdt 5:2007 Safety of household and similar electrical appliances Particular requirements - Storage water heaters (IEC 60335-2-21:1997, MOD)
- AS/NZS 3750.21:2008 Paints for steel structures Undercoat - Solvent-borne
- AS/NZS 60335.2.21:2002/Amdt 2:2005 Household and similar electrical appliances - Safety - Particular requirements for storage water heaters
- ASTM 51026-23 Standard Practice for Using the Fricke Dosimetry System
- ASTM 52303-24 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities
- ASTM A1-00(2018) Standard Specification for Carbon Steel Tee Rails
- ASTM A1000/A1000M-17(2023) Standard Specification for Steel Wire, Carbon and Alloy Specialty Spring Quality
- ASTM A1001-18 Standard Specification for High-Strength Steel Castings in Heavy Sections
- ASTM A1002-16(2020) Standard Specification for Castings, Nickel-Aluminum Ordered Alloy