
【国外标准】 Standard Test Method for Unipolar Magnitude Estimation of Sensory Attributes
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Magnitude estimation may be used to measure and compare the intensities of attributes of a wide variety of products.5.2 Magnitude estimation provides a large degree of flexibility for both the experimenter and the assessor. Once trained in magnitude estimation, assessors are generally able to apply their skill to a wide variety of sample types and attributes, with minimal additional training.5.3 Magnitude estimation is not as susceptible to end-effects as interval scaling techniques. These can occur when assessors are not familiar with the entire range of sensations being presented. Under these circumstances, assessors may assign an early sample to a category which is too close to one end of the scale. Subsequently, they may “run out of scale” and be forced to assign perceptually different samples to the same category. This should not occur with magnitude estimation, as, in theory, there are an infinite number of categories.5.4 Magnitude estimation is one frequently used technique that permits the representation of data in terms of Stevens' Power Law.5.5 The disadvantages of magnitude estimation arise primarily from the requirements of the data analysis.5.5.1 Permitting each assessor to choose a different numerical scale may produce significant assessor effects. This disadvantage can be overcome in a number of ways, as follows. The experimenter must choose the approach most appropriate for the circumstances.5.5.1.1 Experiments can be designed such that analysis of variance can be used to remove the assessor effects and interactions.5.5.1.2 Alternatively, assessors can be forced to a common scale, either by training or by use of external reference samples with assigned values (modulus).5.5.1.3 Finally, each assessor's data can be brought to a common scale by one of a variety of normalizing methods.5.5.2 Logarithms must be applied before carrying out data analysis. This becomes problematic if values are near threshold, as a logarithm of zero cannot be taken (see 11.2.1).5.6 Magnitude estimation should be used:5.6.1 When end-effects are a concern, for example when assessors are not familiar with the entire range of sensations being presented.5.6.2 When Stevens' Power Law is to be applied to the data.5.6.3 Generally, in central location testing with assessors trained in the technique. It is not appropriate for home use or mall intercept testing with consumers.5.7 This test method is only meant to be used with assessors who are specifically trained in magnitude estimation. Do not use this method with untrained assessors or untrained consumers.1.1 This test method describes a procedure for the application of unipolar magnitude estimation to the evaluation of the magnitude of sensory attributes. The test method covers procedures for the training of assessors to produce magnitude estimations and statistical evaluation of the estimations.1.2 Magnitude estimation is a psychophysical scaling technique in which assessors assign numeric values to the magnitude of an attribute. The only constraint placed upon the assessor is that the values assigned should conform to a ratio principle. For example, if the attribute seems twice as strong in sample B when compared to sample A, sample B should receive a value which is twice the value assigned to sample A.1.3 The intensity of attributes such as pleasantness, sweetness, saltiness or softness can be evaluated using magnitude estimation.1.4 Magnitude estimation may provide advantages over other scaling methods, particularly when the number of assessors and the time available for training are limited. With approximately 1 h of training, a panel of 15 to 20 naive individuals can produce data of adequate precision and reproducibility. Any additional training that may be required to ensure that the assessors can properly identify the attribute being evaluated is beyond the scope of this test method.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E1697-05(2020)
标准名称:
Standard Test Method for Unipolar Magnitude Estimation of Sensory Attributes
英文名称:
Standard Test Method for Unipolar Magnitude Estimation of Sensory Attributes标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASC X9 TR 51-2020 Levies Companion Document Uniform Adoption of X9.129 for Levies Version 3.0
- ASTM 51026-23 Standard Practice for Using the Fricke Dosimetry System
- ASTM 52303-24 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities
- ASTM A1-00(2018) Standard Specification for Carbon Steel Tee Rails
- ASTM A1000/A1000M-17(2023) Standard Specification for Steel Wire, Carbon and Alloy Specialty Spring Quality
- ASTM A1001-18 Standard Specification for High-Strength Steel Castings in Heavy Sections
- ASTM A1002-16(2020) Standard Specification for Castings, Nickel-Aluminum Ordered Alloy
- ASTM A1004/A1004M-99(2018) Standard Practice for Establishing Conformance to the Minimum Expected Corrosion Characteristics of Metallic, Painted-Metallic, and Nonmetallic-Coated Steel Sheet Intended for Use as Cold Formed Framing Members
- ASTM A1009-18 Standard Specification for Soft Magnetic MnZn Ferrite Core Materials for Transformer and Inductor Applications
- ASTM A101-04(2019) Standard Specification for Ferrochromium
- ASTM A1010/A1010M-13(2018) Standard Specification for Higher-Strength Martensitic Stainless Steel Plate, Sheet, and Strip
- ASTM A1012-10(2021) Standard Specification for Seamless and Welded Ferritic, Austenitic and Duplex Alloy Steel Condenser and Heat Exchanger Tubes With Integral Fins
- ASTM A1015-01(2018) Standard Guide for Videoborescoping of Tubular Products for Sanitary Applications
- ASTM A1016/A1016M-23 Standard Specification for General Requirements for Ferritic Alloy Steel, Austenitic Alloy Steel, and Stainless Steel Tubes
- ASTM A102-04(2019) Standard Specification for Ferrovanadium