
【国外标准】 Standard Specification for Annealed Aluminum and Aluminum-Alloy Foil for Flexible Barrier, Food Contact, and Other Applications
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
This specification covers annealed aluminum and aluminum-alloy foil used in packaging, which includes food handling and processing applications, requiring flexible barrier materials, and other general applications. The foil may also be as supplied or laminated to other materials, such as paper or plastic films. Chemical composition shall be in conformity with provisions herein, and shall be determined through suitable chemical and spectrochemical methods. Tensile breaking load limits shall be as agreed, and shall be tested twice with test methods for tension testing of metallic foil using two samples from different rolls of foil.1.1 This specification covers annealed aluminum and aluminum-alloy foil containing 98.00 % minimum aluminum and in thicknesses 0.00025 in. (0.0064 mm) to, but not including, 0.006 in. (0.15 mm). Alloys (see Note 1) covered by this specification include, but are not limited to 1100, 1145, 1235, 8011, 8079, and 8111, which conform to the requirements of 6.1 and Table 1. Unless otherwise specified by the purchaser, the alloy to be supplied shall be left to the discretion of the producer.1.2 The foil is for use in packaging, which includes food handling and processing applications, requiring flexible barrier materials, and other general applications. The foil may be used as supplied or laminated to other materials, such as paper or plastic films.1.3 For acceptance criteria for inclusion of new aluminum and aluminum alloys in this specification, see Annex A1.1.4 The values stated in inch-pound units are to be regarded as the standard. The SI values in parentheses are for information only.1.5 The following precautionary caveat pertains only to the test method portion of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.NOTE 1: Throughout this specification, use of the term alloy in the general sense includes aluminum as well as aluminum alloy.NOTE 2: If the alloy is specified by the purchaser, its designation shall be in accordance with ANSI H35.1. The equivalent Unified Numbering System alloy designations are those shown in 1.1 preceded by A9, for example, A91100 for aluminum 1100 in accordance with Practice E527.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM B479-19
标准名称:
Standard Specification for Annealed Aluminum and Aluminum-Alloy Foil for Flexible Barrier, Food Contact, and Other Applications
英文名称:
Standard Specification for Annealed Aluminum and Aluminum-Alloy Foil for Flexible Barrier, Food Contact, and Other Applications标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E1160-13(2021) Standard Guide for On-Site Inspection and Verification of Operation of Solar Domestic Hot Water Systems
- ASTM E1162-11(2019) Standard Practice for Reporting Sputter Depth Profile Data in Secondary Ion Mass Spectrometry (SIMS)
- ASTM E1164-23 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation
- ASTM E1173-23 Standard Practice for Evaluation of Preoperative, Precatheterization, or Preinjection Skin Preparations
- ASTM E1174-21 Standard Test Method for Evaluation of the Effectiveness of Healthcare Personnel Handwash Formulations
- ASTM E1179-13(2019) Standard Specification for Sound Sources Used for Testing Open Office Components and Systems
- ASTM E1180-08(2021) Standard Practice for Preparing Sulfur Prints for Macrostructural Evaluation
- ASTM E1198-19 Standard Practice for Sampling Zooplankton with Pumps
- ASTM E1199-19 Standard Practice for Sampling Zooplankton with a Clarke-Bumpus Plankton Sampler
- ASTM E1208-21 Standard Practice for Fluorescent Liquid Penetrant Testing Using the Lipophilic Post-Emulsification Process
- ASTM E1211/E1211M-17 Standard Practice for Leak Detection and Location Using Surface-Mounted Acoustic Emission Sensors
- ASTM E1213-14(2022) Standard Practice for Minimum Resolvable Temperature Difference for Thermal Imaging Systems
- ASTM E1218-21 Standard Guide for Conducting Static Toxicity Tests with Microalgae
- ASTM E1219-21 Standard Practice for Fluorescent Liquid Penetrant Testing Using the Solvent-Removable Process
- ASTM E122-17(2022) Standard Practice for Calculating Sample Size to Estimate, With Specified Precision, the Average for a Characteristic of a Lot or Process