
【国外标准】 Standard Test Method for Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Flash point and fire point of a liquid are physical properties that may be used to define their flammability hazards. The flash point may be used to classify materials in government regulations.1.1 This test method covers the determination by Tag Open-Cup Apparatus of the flash point and fire point of liquids having flash points between −18 and 165°C (0 and 325°F) and fire points up to 325°F.1.2 This test method, when applied to paints and resin solutions that tend to skin over or that are very viscous, gives less reproducible results than when applied to solvents.NOTE 1: In order to conserve time and sample, the fire point of a material may be determined by the Tag Open-Cup Method by continuing the heating of the specimen to its fire point. Fire points may also be determined by Test Method D92, which should be used for fire points beyond the scope of this test method.1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.4 This standard should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors pertinent to an assessment of the fire hazard of a particular end use.1.5 Warning—Mercury has been designated by many regulatory agencies as a hazardous material that can cause central nervous system, kidney and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury containing products. See the applicable product Safety Data Sheet (SDS) for details and EPA’s website, http://www.epa.gov/mercury/faq.htm, for additional information. Users should be aware that selling mercury and/or mercury containing products into your state or country may be prohibited by law.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D1310-14(2021)
标准名称:
Standard Test Method for Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus
英文名称:
Standard Test Method for Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E1160-13(2021) Standard Guide for On-Site Inspection and Verification of Operation of Solar Domestic Hot Water Systems
- ASTM E1162-11(2019) Standard Practice for Reporting Sputter Depth Profile Data in Secondary Ion Mass Spectrometry (SIMS)
- ASTM E1164-23 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation
- ASTM E1173-23 Standard Practice for Evaluation of Preoperative, Precatheterization, or Preinjection Skin Preparations
- ASTM E1174-21 Standard Test Method for Evaluation of the Effectiveness of Healthcare Personnel Handwash Formulations
- ASTM E1179-13(2019) Standard Specification for Sound Sources Used for Testing Open Office Components and Systems
- ASTM E1180-08(2021) Standard Practice for Preparing Sulfur Prints for Macrostructural Evaluation
- ASTM E1198-19 Standard Practice for Sampling Zooplankton with Pumps
- ASTM E1199-19 Standard Practice for Sampling Zooplankton with a Clarke-Bumpus Plankton Sampler
- ASTM E1208-21 Standard Practice for Fluorescent Liquid Penetrant Testing Using the Lipophilic Post-Emulsification Process
- ASTM E1211/E1211M-17 Standard Practice for Leak Detection and Location Using Surface-Mounted Acoustic Emission Sensors
- ASTM E1213-14(2022) Standard Practice for Minimum Resolvable Temperature Difference for Thermal Imaging Systems
- ASTM E1218-21 Standard Guide for Conducting Static Toxicity Tests with Microalgae
- ASTM E1219-21 Standard Practice for Fluorescent Liquid Penetrant Testing Using the Solvent-Removable Process
- ASTM E122-17(2022) Standard Practice for Calculating Sample Size to Estimate, With Specified Precision, the Average for a Characteristic of a Lot or Process