
【国外标准】 Standard Test Method for Measuring Apparent Viscosity at High-Temperature and High-Shear Rate by Multicell Capillary Viscometer
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Viscosity is an important property of fluid lubricants. The viscosity of all fluids varies with temperature. Many common petroleum lubricants are non-Newtonian: their viscosity also varies with shear rate. The usefulness of the viscosity of lubricants is greatest when the viscosity is measured at or near the conditions of shear rate and temperature that the lubricants will experience in service.5.2 The conditions of shear rate and temperature of this test method are thought to be representative of those in the bearing of automotive engines in severe service.5.3 Many equipment manufacturers and lubricant specifications require a minimum high-temperature high-shear viscosity at 150 °C and 106 s−1. The shear rate in capillary viscometers varies across the radius of the capillary. The apparent shear rate at the wall for this test method is increased to compensate for the variable shear rate.35.4 This test was evaluated in an ASTM cooperative program.61.1 This test method covers the laboratory determination of high-temperature high-shear (HTHS) viscosity of engine oils at a temperature of 150 °C using a multicell capillary viscometer containing pressure, temperature, and timing instrumentation. The shear rate for this test method corresponds to an apparent shear rate at the wall of 1.4 million reciprocal seconds (1.4 × 106 s−1).3 This shear rate has been found to decrease the discrepancy between this test method and other high-temperature high-shear test methods3 (Test Methods D4683 and D4741) used for engine oil specifications. Viscosities are determined directly from calibrations that have been established with Newtonian oils with nominal viscosities from 1.4 mPa·s to 5.0 mPa·s at 150 °C. The precision has only been determined for the viscosity range 1.45 mPa·s and 5.05 mPa·s at 150 °C for the materials listed in the precision section.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.2.1 The centiPoise (cP) is a non-SI metric unit of viscosity that is numerically equal to the milliPascal-second (mPa·s).1.2.2 Pounds per square inch (psi) is a non-SI unit of pressure that is approximately equal to 6.895 kPa. These units are provided for information only in 6.1.1, 7.3, 9.1.2.1, and the tables.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D5481-21
标准名称:
Standard Test Method for Measuring Apparent Viscosity at High-Temperature and High-Shear Rate by Multicell Capillary Viscometer
英文名称:
Standard Test Method for Measuring Apparent Viscosity at High-Temperature and High-Shear Rate by Multicell Capillary Viscometer标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 1038.21.1.2-2002 (R2013) Coal and coke - Analysis and testing Higher rank coal and coke - Relative density - Analysis sample/volumetric method
- AS 1038.21.2-1992 Coal and coke - Analysis and testing Higher rank coal and coke - Relative density - Lump sample
- AS 1807.21-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of inward air velocity of Class I biological safety cabinets
- AS 2005.21.1-1990 Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) - Standardized fuse systems - Fuses with fuse-links with blade contacts
- AS 2005.21.2-1990 Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) - Standardized fuse systems - Fuses with fuse-links for bolted connections
- ASTM D130-19 Standard Test Method for Corrosiveness to Copper from Petroleum Products by Copper Strip Test
- ASTM D1301-91(2020) Standard Test Methods for Chemical Analysis of White Lead Pigments
- ASTM D1304-99(2020)e1 Standard Test Methods for Adhesives Relative to Their Use as Electrical Insulation
- ASTM D1308-20 Standard Test Method for Effect of Household Chemicals on Clear and Pigmented Coating Systems
- ASTM D1310-14(2021) Standard Test Method for Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus
- ASTM D1318-23 Standard Test Method for Sodium in Residual Fuel Oil (Flame Photometric Method)
- ASTM D1319-20a Standard Test Method for Hydrocarbon Types in Liquid Petroleum Products by Fluorescent Indicator Adsorption
- ASTM D1322-23 Standard Test Method for Smoke Point of Kerosene and Aviation Turbine Fuel
- ASTM D1327/D1327M-04(2020) Standard Specification for Bitumen-Saturated Woven Burlap Fabrics Used in Roofing and Waterproofing
- ASTM D1334-18 Standard Test Method for Wool Content of Raw Wool—Commercial Scale