【国外标准】 Standard Test Method for Structural Performance of Thermal Barriers in Fenestration Products
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Thermal barriers require sufficient structural strength to carry the loads imposed on fenestration members while reducing the heat transfer through the depth of the framing members throughout their service life.5.2 Sustained gravity, bending and tensile loads that stress the thermal barrier (that is, glazing infill weight, wind loads, and glazing gasket pressure) are not covered by this test method.5.3 The reader is encouraged to read AAMA TIR-A8 for further information on thermal barriers and testing.1.1 This test method evaluates the longitudinal shear strength before and after thermal cycling for thermally broken composite thermal barriers used in framing of windows, doors, and skylights. It also evaluates the ability of a thermal barrier to maintain its longitudinal dimension after thermal cycling.1.2 This test method is applicable to all fenestration products that are constructed with structural thermal barriers that are affixed along their length to the adjoining metal profile1.3 This test method is meant to be applicable to many types of fenestration frame types and is not meant to be specific to any single frame construction type.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E2692-10(2018)
标准名称:
Standard Test Method for Structural Performance of Thermal Barriers in Fenestration Products
英文名称:
Standard Test Method for Structural Performance of Thermal Barriers in Fenestration Products标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 1012.10-1985 Methods of testing concrete Method for the determination of indirect tensile strength of concrete cylinders ('Brazil' or splitting test)
- AS 1012.10-1985/Amdt 1-1987 Methods of testing concrete - Method for the determination of indirect tensile strength of concrete cylinders ('Brazil' or splitting test)
- AS 1038.10.1-2003 (R2013) Coal and coke - Analysis and testing Determination of trace elements - Coal, coke and fly-ash - Determination of eleven trace elements - Flame atomic absorption spectrometric method
- AS 1038.10.5.1-2003 (R2013) Coal and coke - Analysis and testing - Coal, coke and fly-ash - Trace elements - Determination of mercury content - Tube combustion method
- AS 1085.10-2002 (R2013) Railway track material Rail anchors
- AS 1301.P10rp-1986 Methods of test for pulp and paper (metric units) Determination of moisture in wood chips - Distillation method
- AS 1366.1-1992 (R2018)/Amdt 1-1992 Rigid cellular plastics sheets for thermal insulation - Rigid cellular polyurethane (RC/PUR)
- AS 1366.3-1992 (R2018)/Amdt 1-1993 Rigid cellular plastics sheets for thermal insulation - Rigid cellular polystyrene - Moulded (RC/PS - M)
- AS 1418.10(Int)-2004/Amdt 2-2007 Cranes, hoists and winches Elevating work platforms
- AS 1418.10(Int)-2004/Amdt 3-2008 Cranes, hoists and winches Elevating work platforms
- AS 1684 Supp 10-1992 National Timber Framing Code - Timber framing span tables - Seasoned softwood - Stress Grade F7 (Supplement to AS 1684-1992)
- AS 1684.2 N1/N2 Supp 10-2006 Residential timber-framed construction Non-cyclonic areas - N1/N2 Supplement 10: Timber framing span tables - Wind classification N1/N2 - Unseasoned softwood - Stress Grade F5 (Supplement to AS 1684.2-2006)
- AS 1684.2 N1/N2 Supp 10-2010 Residential timber-framed construction Non-cyclonic areas - N1/N2 Supplement 10: Timber framing span tables - Wind classification N1/N2 - Unseasoned softwood - Stress Grade F5 (Supplement to AS 1684.2-2010)
- AS 1684.2 N3 Supp 10-2006 Residential timber-framed construction Non-cyclonic areas - N3 Supplement 10: Timber framing span tables - Wind classification N3 - Unseasoned softwood - Stress Grade F5 (Supplement to AS 1684.2-2006)
- AS 1684.2 N3 Supp 10-2010 Residential timber-framed construction Non-cyclonic areas - N3 Supplement 10: Timber framing span tables - Wind classification N3 - Unseasoned softwood - Stress Grade F5 (Supplement to AS 1684.2-2010)