【国外标准】 Standard Test Method for Analysis of Low-Alloy Steels by Wavelength Dispersive X-Ray Fluorescence Spectrometry
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This test method is suitable for manufacturing control and for verifying that a product meets specifications. This test method provides rapid, multi-element determinations with sufficient accuracy to ensure product quality and to minimize production delays. The analytical performance data may be used as a benchmark to determine if similar X-ray spectrometers provide equivalent precision and accuracy, or if the performance of a particular X-ray spectrometer has changed.5.2 Calcium is sometimes added to steel to affect inclusion shape which enhances certain mechanical properties of steel. This test method is useful for determining the residual calcium in the steel after such treatment.5.2.1 Because calcium occurs primarily in inclusions, the precision of this test method is a function of the distribution of the calcium-bearing inclusions in the steel. The variation of determinations on freshly prepared surfaces will give some indication of the distribution of these inclusions.1.1 This test method covers the wavelength dispersive X-ray fluorescence analysis of low-alloy steels for the following elements:Element Mass FractionRange, %Calcium 0.001 to 0.007Chromium 0.04 to 2.5Cobalt 0.03 to 0.2Copper 0.03 to 0.6Manganese 0.04 to 2.5Molybdenum 0.005 to 1.5Nickel 0.04 to 3.0Niobium 0.002 to 0.1Phosphorus 0.010 to 0.08Silicon 0.06 to 1.5Sulfur 0.009 to 0.1Vanadium 0.012 to 0.61.1.1 Unless exceptions are noted, mass fraction ranges can be extended and additional elements can be included by the use of suitable reference materials and measurement conditions. Deviations from the published scope must be validated by experimental means. See Guide E2857 for information on validation options.1.2 The values stated in the International System of Units (SI) are to be regarded as standard. The values given in parentheses are mathematical conversions to other units that are provided for information only, because they may be used in older software and laboratory procedures.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E1085-22
标准名称:
Standard Test Method for Analysis of Low-Alloy Steels by Wavelength Dispersive X-Ray Fluorescence Spectrometry
英文名称:
Standard Test Method for Analysis of Low-Alloy Steels by Wavelength Dispersive X-Ray Fluorescence Spectrometry标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E1014-12(2021) Standard Guide for Measurement of Outdoor A-Weighted Sound Levels
- ASTM E1016-07(2020) Standard Guide for Literature Describing Properties of Electrostatic Electron Spectrometers
- ASTM E1019-18 Standard Test Methods for Determination of Carbon, Sulfur, Nitrogen, and Oxygen in Steel, Iron, Nickel, and Cobalt Alloys by Various Combustion and Inert Gas Fusion Techniques
- ASTM E1021-15(2019) Standard Test Method for Spectral Responsivity Measurements of Photovoltaic Devices
- ASTM E103-17 Standard Practice for Rapid Indentation Hardness Testing of Metallic Materials
- ASTM E1030/E1030M-21 Standard Practice for Radiographic Examination of Metallic Castings
- ASTM E1035-18(2023) Standard Practice for Determining Neutron Exposures for Nuclear Reactor Vessel Support Structures
- ASTM E1036-15(2019) Standard Test Methods for Electrical Performance of Nonconcentrator Terrestrial Photovoltaic Modules and Arrays Using Reference Cells
- ASTM E1038-10(2019) Standard Test Method for Determining Resistance of Photovoltaic Modules to Hail by Impact with Propelled Ice Balls
- ASTM E104-20a Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Solutions
- ASTM E1044-96(2024) Standard Specification for Glass Serological Pipets (General Purpose and Kahn)
- ASTM E1046-85(2021) Standard Specification for Glass Westergren Tube, Disposable
- ASTM E1048-88(2021) Standard Specification for Color-Coding Pipets or Containers Coated With Anticoagulants
- ASTM E1049-85(2023) Standard Practices for Cycle Counting in Fatigue Analysis
- ASTM E1052-20 Standard Practice to Assess the Activity of Microbicides against Viruses in Suspension