微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 345元 / 折扣价: 294

在线阅读 收 藏
AS 1085.12-2002 (R2013) Railway track material Insulated joint assemblies 现行 发布日期 :  2002-08-01 实施日期 : 

定价: 605元 / 折扣价: 515 加购物车

在线阅读 收 藏
AS 1085.12-1999 Railway permanent way materials Insulated joint assemblies 现行 发布日期 :  1999-07-05 实施日期 : 

定价: 689元 / 折扣价: 586 加购物车

在线阅读 收 藏

定价: 260元 / 折扣价: 221 加购物车

在线阅读 收 藏

This specification covers the material requirements for preformed elastomeric strip seals and the corresponding steel locking edge rail used in expansion joint sealing. The scope of this specification is limited to preformed non-reinforced strip seals that mechanically lock into structural steel locking lugs. The sealing element can consist of a single layer strip or have multiple webs depending on individual project requirements. When used on highway bridges, limits on maximum joint opening and minimum steel thicknesses need to be addressed. The adhesive-lubricant used to install the preformed seal into the steel locking edge rail shall be a one part moisture curing polyurethane compound. The elastomeric seals shall conform to the physical properties prescribed for (1) tensile strength, (2) elongation at break, (3) hardness, (4) oven aging, (5) oil swell, (6) ozone resistance, (7) low temperature stiffening, and (8) compression set. Requirements for preformed elastomeric seal dimensions, sampling, and test methods to determine compliance with the specified physical properties are given.1.1 This specification covers the material requirements for preformed elastomeric strip seals and the corresponding steel locking edge rail used in expansion joint sealing. The scope of this specification is limited to preformed non-reinforced strip seals that mechanically lock into structural steel locking lugs. The sealing element can consist of a single layer strip or have multiple webs depending on individual project requirements. The structural steel locking edge rail shall be anchored into the structure in accordance with the purchaser's specific details. While the scope of this specification is limited to the materials used in fabrication of strip sealing systems, it is recommended that a practical means of testing the watertightness aspects of the individual systems either in the field or at a testing laboratory be developed. When used on highway bridges, limits on maximum joint opening and minimum steel thicknesses need to be addressed.1.2 The values stated in the inch-pound system shall be considered as standard.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

1.1 This specification covers machine-made reinforced thermosetting epoxy resin pipe and fittings nominal pipe size (NPS) 2 in. (50 mm) through 12 in. (304 mm) diameter to be used for continuous service in condensate return lines for the specific maximum temperature and pressure covered by this specification, 250°F (121°C) and 125 psig (862 kPa). 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are provided for information purposes only. 1.3 The dimensionless designator NPS has been substituted in this specification for such traditional terms as "nominal diameter", "size", and "nominal size". 1.4 The following safety hazards caveat pertains only to the test method portion, Section 10, of this specification: 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note 1-There is no similar or equivalent ISO standard.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

4.1 Types of architectural joint systems included in this test method are the following:4.1.1 Metallic systems;4.1.2 Compression seals:4.1.2.1 With frames, and4.1.2.2 Without frames,4.1.3 Strip seals;4.1.4 Preformed sealant systems (see Appendix X1):4.1.4.1 With frames, and4.1.4.2 Without frames,4.1.5 Preformed foams and sponges:4.1.5.1 Self-Expanding, and4.1.5.2 Nonexpanding,4.1.6 Fire barriers:4.1.6.1 Used as joint systems, and4.1.6.2 Used as a part of the joint system, and4.1.7 Elastomeric membrane systems:4.1.7.1 With nosing material(s), and4.1.7.2 Without nosing material(s).4.2 This test method will assist users, producers, building officials, code authorities, and others in verifying some performance characteristics of representative specimens of architectural joint systems under common test conditions. The following performance characteristics are verifiable:4.2.1 The maximum joint width,4.2.2 The minimum joint width, and4.2.3 The movement capability.4.3 This test compares similar architectural joint systems by cycling but does not accurately reflect the system's application. Similar refers to the same type of architectural system within the same subsection under 4.1.4.4 This test method does not provide information on:4.4.1 Durability of the architectural joint system under actual service conditions, including the effects of cycled temperature on the joint system,4.4.2 Loading capability of the system and the effects of a load on the functional parameters established by this test method,4.4.3 Rotational, vertical, and horizontal shear capabilities of the specimen,4.4.4 Any other attributes of the specimen, such as fire resistance, wear resistance, chemical resistance, air infiltration, watertightness, and so forth, and4.4.5 Testing or compatibility of substrates.4.5 This test method is only to be used as one element in the selection of an architectural joint system for a particular application. It is not intended as an independent pass/fail acceptance procedure. In conjunction with this test method, other test methods are to be used to evaluate the importance of other service conditions such as durability, structural loading, and compatibility.1.1 This test method covers testing procedures for architectural joint systems. This test method is intended for the following uses for architectural joint systems:1.1.1 To verify movement capability information supplied to the user by the producer,1.1.2 To standardize comparison of movement capability by relating it to specified nominal joint widths,1.1.3 To determine the cyclic movement capability between specified minimum and maximum joint widths without visual deleterious effects, and1.1.4 To provide the user with graphic information, drawings or pictures in the test report, depicting them at minimum, maximum, and nominal joint widths during cycling.1.2 This test method is intended to be used only as part of a specification or acceptance criterion due to the limited movements tested.1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
ASTM F2836-18 Standard Practice for Gasket Constants for Bolted Joint Design Active 发布日期 :  1970-01-01 实施日期 : 

5.1 This practice determines the room temperature gasket constants Gb and a for initial seating and Gs for operating conditions as related to the tightness behavior of pressurized bolted flanged connections. These constants are used in determining the design bolt load for gasketed bolted joints.5.2 This practice is suitable for all the types of gaskets and facings as are considered by the ASME Division 1 Code. This includes ASME B16.5 raised facings, nubbin-type facings, O-ring grooves, and a wide variety of gaskets including spiral wound, flat sheet, solid metal, jacketed, and other types of gaskets common to process and power industry pressurized equipment.5.3 These constants are intended for direct use in determining ASME Code design calculations for bolted flanged joints. An appendix of the ASME Boiler and Pressure Vessel Code, Section VIII, Division 1 will refer to the gasket constants Gb, a, and Gs produced by this practice. The user and bolted joint designer are cautioned that gasket constants Gb, a, and Gs and any gasket design stresses calculated from these may not be conservative for design stresses below S1 or beyond S13 as indicated in Table 3.5.4 When required, this practice evaluates both the mechanical and leakage resistance of gaskets to excessive compression to determine their maximum assembly stress, Sc.5.5 This test procedure is a gasket tightness characterization test and is not considered as a gasket manufacturing quality control test.1.1 This practice determines room temperature gasket tightness design constants for pressurized bolted flanged connections such as those designed in accordance with the ASME Boiler and Pressure Vessel Code.1.2 This practice applies mainly to all types of circular gasket products and facings typically used in process or power plant pressure vessels, heat exchangers, and piping including solid metal, jacketed, spiral wound, and sheet-type gaskets. As an optional extension of this practice, the maximum assembly stress for those gaskets may also be determined by this procedure.1.3 Units—The values stated in SI units are to be regarded as the standard, but other units may be included.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

5.1 This is not a routine test. The values recorded are applicable only to the sewer being tested and at the time of testing.1.1 This practice covers procedures for testing the joints of installed precast concrete pipe sewer lines, when using either air or water under low pressure to demonstrate the integrity of the joint and the construction procedures. This practice is used for testing precast concrete sewer lines utilizing rubber gasket sealed joints.NOTE 1: The user of this practice is advised that methods described herein may also be used as a preliminary test to enable the manufacturer or installer to demonstrate the condition of sewer pipe prior to delivery.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.NOTE 2: The owner shall specify the following: who will conduct, observe, and furnish labor, material, and measuring devices and pay for the tests; who is responsible for determining local ground conditions; and whether an air or water test is to be used.NOTE 3: The user of this practice is advised that test criteria presented in this practice are similar to those in general use. Pipe shall be accepted by infiltration or exfiltration testing utilizing Practice C969 (C969M).NOTE 4: Test times tabulated and the rate of air loss in this practice are based on successful testing of installed pipelines. However, since air and water have different physical properties, retests of some pipelines not meeting field air tests have been successful when tested with water.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautions are given in Section 6.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 This is not a routine test. The values recorded are applicable only to the sewer being tested and at the time of testing.1.1 This practice covers procedures for testing the joints of installed precast concrete pipe sewer lines, when using either air or water under low pressure to demonstrate the integrity of the joint and the construction procedures. This practice is used for testing precast concrete sewer lines utilizing rubber gasket sealed joints.NOTE 1: The user of this practice is advised that methods described herein may also be used as a preliminary test to enable the manufacturer or installer to demonstrate the condition of sewer pipe prior to delivery.1.2 This practice is the SI companion of Practice C1103.NOTE 2: The owner shall specify the following: who will conduct, observe, and furnish labor, material, and measuring devices and pay for the tests; who is responsible for determining local ground conditions; and whether an air or water test is to be used.NOTE 3: The user of this practice is advised that test criteria presented in this practice are similar to those in general use. Pipe shall be accepted by infiltration or exfiltration testing utilizing Practice C969M.NOTE 4: Test times tabulated and the rate of air loss in this standard are based on successful testing of installed pipelines. However, since air and water have different physical properties, retests of some pipelines not meeting field air tests have been successful when tested with water.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific safety precautions are given in Section 6.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

5.1 The expanded limits of the Adjunct for VCF are defined in a mixture of terms of customary and metric units. Table 1 shows the defining limits and their associated units in bold italics. Also shown in Table 1 are the limits converted to their equivalent units (and, in the case of the densities, other base temperatures).5.2 Note that only the precision levels of the defining values shown in Table 1 are correct. The other values showing converted units have been rounded to the significant digits shown; as rounded values, they may numerically fall just outside of the actual limits established by the defining values.5.3 Table 2 provides a cross-reference between the historical table designations and the corresponding section in the Adjunct for VCF. Note that procedure paragraphs 11.1.6.3 (U.S. customary units) and 11.1.7.3 (metric units) provide methods for correcting on-line density measurements from live conditions to base conditions and then to compute CTPL factors for continuous volume corrections to base conditions.5.4 When a glass hydrometer is used to measure the density of a liquid, special corrections must be made to account for the thermal expansion of the glass when the temperature is different from that at which the hydrometer was calibrated. The 1980 CTL Tables had generalized equations to correct glass hydrometer readings, and these corrections were part of the printed odd-numbered tables. However, detailed procedures to correct a glass hydrometer reading are beyond the scope of the Adjunct for VCF. The user should refer to the appropriate sections of API MPMS Chapter 9 or other appropriate density/hydrometer standards for guidance.5.5 The set of correlations given in the Adjunct for VCF is intended for use with petroleum fluids comprising either crude oils, refined products, or lubricating oils that are single-phase liquids under normal operating conditions. The liquid classifications listed here are typical terms used in the industry, but local nomenclature may vary. The list is illustrative and is not meant to be all-inclusive.5.6 Crude Oils—A crude oil is considered to conform to the commodity group Generalized Crude Oils if its density falls in the range between approximately –10°API to 100°API. Crude oils that have been stabilized for transportation or storage purposes and whose API gravities lie within that range are considered to be part of the Crude Oil group. Also, aviation Jet B (JP-4) is best represented by the Crude Oil correlation.5.7 Refined Products—A refined product is considered to conform to the commodity group of Generalized Refined Products if the fluid falls within one of the refined product groups. Note the product descriptors are generalizations. The commercial specification ranges of some products may place their densities partly within an adjacent class (for example, a low-density diesel may lie in the jet fuel class). In such cases, the product should be allocated to the class appropriate to its density, not its descriptor. The groups are defined as follows:5.7.1 Gasoline—Motor gasoline and unfinished gasoline blending stock with a base density range between approximately 50°API and 85°API. This group includes substances with the commercial identification of: premium gasoline, unleaded gasoline, motor spirit, clear gasoline, low-lead gas, motor gasoline, catalyst gas, alkylate, catalytic cracked gasoline, naphtha, reformulated gasoline, and aviation gasoline.5.7.2 Jet Fuels—Jet fuels, kerosene, and Stoddard solvents with a base density range between approximately 37°API and 50°API. This group includes substances with the commercial identification of: aviation kerosene K1 and K2, aviation Jet A and A-1, kerosene, Stoddard solvent, JP-5, and JP-8.5.7.3 Fuel Oils—Diesel oils, heating oils, and fuel oils with a base density range between approximately –10°API and 37°API. This group includes substances with the commercial identification of: No. 6 fuel oil, fuel oil PA, low-sulfur fuel oil, LT (low temperature) fuel oil, fuel oil, fuel oils LLS (light low sulfur), No. 2 furnace oil, furnace oil, auto diesel, gas oil, No. 2 burner fuel, diesel fuel, heating oil, and premium diesel.5.8 Lubricating Oils—A lubricating oil is considered to conform to the commodity group Generalized Lubricating Oils if it is a base stock derived from crude oil fractions by distillation or asphalt precipitation. For the purpose of the Adjunct for VCF, lubricating oils have initial boiling points greater than 700 °F (370 °C) and densities in the range between approximately –10°API to 45°API.5.9 Special Applications—Liquids that are assigned the special applications category are generally relatively pure products or homogeneous mixtures with stable (unchanging) chemical composition that are derived from petroleum (or are petroleum-based with minor proportions of other constituents) and have been tested to establish a specific thermal expansion factor for the particular fluid. These tables should be considered for use when:5.9.1 The generalized commodity groups' parameters are suspected of not adequately representing the thermal expansion properties of the liquid.5.9.2 A precise thermal expansion coefficient can be determined by experiment. A minimum of ten temperature/density data points is recommended to use this method. See 11.1.5.2 of the Adjunct for VCF for the procedure to calculate the thermal expansion coefficient from measured density data.5.9.3 Buyer and seller agree that, for their purpose, a greater degree of equity can be obtained using factors specifically measured for the liquid involved in the transaction.5.10 Refer to paragraphs 11.1.2.4 and 11.1.2.5 in the Adjunct for VCF for a complete description of the suitability of the implementation procedures for specific hydrocarbon liquids.1.1 This guide provides information related to the algorithm and implementation procedure but does not contain the full set of algorithms. The algorithms, instructions, procedures, and examples are located in the associated supplementary adjuncts. The Adjunct for Volume Correction Factors (VCF) for temperature and pressure volume correction factors for generalized crude oils, refined products, and lubricating oils provides the algorithm and implementation procedure for the correction of temperature and pressure effects on density and volume of liquid hydrocarbons. Natural gas liquids (NGLs) and liquefied petroleum gases (LPGs) are excluded from consideration in this standard but may be found in API MPMS Chapter 11.2.4/GPA 8217 Temperature Correction for NGL and LPG. As this Adjunct for VCF will be applied to a variety of applications, the output parameters of CTL, Fp, CPL, and CTPL may be used as specified in other standards.1.2 Including the pressure correction in the Adjunct for VCF represents an important change from the “temperature only” correction factors given in the 1980 Petroleum Measurement Tables. However, if the pressure is one atmosphere (the standard pressure), then there is no pressure correction and the standard/adjunct(s) will give CTL values consistent with the 1980 Petroleum Measurement Tables.1.3 The Adjunct for VCF covers general procedures for the conversion of input data to generate CTL, Fp, CPL, and CTPL values at the user-specified base temperature and pressure (Tb, Pb). Two sets of procedures are included for computing volume correction factor: one set for data expressed in customary units (temperature in °F, pressure in psig); the other for the metric system of units (temperature in °C, pressure in kPa or bar).NOTE 1: In contrast to the 1980 Petroleum Measurement Tables, the metric procedures require the procedure for customary units be used first to compute density at 60 °F. This value is then further corrected to give the metric output. The metric procedures now incorporate the base temperature of 20 °C in addition to 15 °C.1.4 The procedures in the Adjunct for VCF recognize three distinct commodity groups: crude oil, refined products, and lubricating oils. A procedure is also provided for determining volume correction for special applications where the generalized commodity groups’ parameters may not adequately represent the thermal expansion properties of the liquid and a precise thermal expansion coefficient has been determined by experiment. Procedures for determining Volume Correction Factors (VCF) for Denatured Ethanol can be found in API MPMS Chapter 11.3.3, Miscellaneous Hydrocarbon Properties—Denatured Ethanol Density and Volume Correction Factors, 3rd edition. Procedures for determining Volume Correction Factors (VCF) for Gasoline and Denatured Ethanol Blends can be found in API MPMS Chapter 11.3.4, Miscellaneous Hydrocarbon Properties—Denatured Ethanol and Gasoline Component Blend Densities and Volume Correction Factors, 1st edition.1.5 The values stated in either SI units or inch‐pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This specification covers the material, manufacturing, and physical requirements for preformed silicone joint seals used in bridges. The seal consists of a silicone rubber gland preformed to a continuous length and is designed to prevent any tension from occurring in the seal or bonding point during normal movement. The seal is installed by bonding it to the joint header with a silicone-based adhesive, sealing the joint to prevent liquid intrusion. Physical requirements for the preformed silicone joint seal gland cover resistance to accelerated weathering, tensile strength, elongation at break, hardness, tear strength, compression set, and heat-aged properties, whereas physical requirements for the silicone-based adhesive cover tensile strength, elongation at break, sag/flow, tack-free time, resistance to UV, and cure through to 1/4-in. thickness.1.1 This specification covers the material requirements for preformed silicone joint seals for bridges. The seal consists of a silicone rubber gland preformed to a continuous length. Its design shall prevent any tension from occurring in the seal or bonding point during normal movement. The seal is installed by bonding it to the joint header with a silicone-based adhesive and is designed to seal the joint, preventing liquid intrusion.1.2 The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
86 条记录,每页 15 条,当前第 1 / 6 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页