微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 689元 / 折扣价: 586

在线阅读 收 藏

定价: 689元 / 折扣价: 586

在线阅读 收 藏

定价: 689元 / 折扣价: 586

在线阅读 收 藏

定价: 605元 / 折扣价: 515

在线阅读 收 藏

定价: 156元 / 折扣价: 133

在线阅读 收 藏

定价: 345元 / 折扣价: 294

在线阅读 收 藏

定价: 605元 / 折扣价: 515 加购物车

在线阅读 收 藏

定价: 345元 / 折扣价: 294

在线阅读 收 藏

定价: 481元 / 折扣价: 409 加购物车

在线阅读 收 藏

定价: 689元 / 折扣价: 586 加购物车

在线阅读 收 藏

定价: 156元 / 折扣价: 133

在线阅读 收 藏
ASTM D6215-98a Standard Guide for Removal of Oily Soils from Metal Surfaces (Withdrawn 2004) Withdrawn, No replacement 发布日期 :  1970-01-01 实施日期 : 

1.1 This guide covers the determination of the amount of an oily soil removed from a metal surface.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

5.1 To be meaningful, walkway tribometer results must correlate the slip characteristics of a surface or contaminant, or both, to the actual propensity for human slips. To achieve this goal, walkway tribometer models must be validated against a standard with relevance to human ambulation.5.2 This practice prescribes a series of reference surfaces with known relative slip potential ranging from very high to low (as defined by laboratory conditions only) upon which walkway tribometer models can be validated. The relative slip potential of each reference surface was established from human subject walking trials.35.3 The following should be considered in applying the validation and calibration obtained by this practice:5.3.1 The scientific study upon which the validation process is based was conducted with a select population of young adults (mean age 26 years) who were free from gait deviations while walking in a straight path on a level surface with a mean walking velocity of 2.18 m/s. This walking velocity is faster than the average walking velocity for the general population which includes a much wider age range with greater variability; thus, the study sample population of pedestrians and conditions is not representative of the larger general population of pedestrians.5.3.2 All subjects walked in Oxford-style shoes whose soles were constructed of smooth styrene butadiene rubber (SBR) with 75A Shore hardness. The shoe style and sole material is not representative of all combinations available in the marketplace.5.3.3 The reference surfaces defined in this practice are not representative of all walkway surfaces. The outcome of the validation practice reflects performance on the type of reference surfaces and surface conditions defined in this practice only. Validation and calibration of a walkway tribometer as defined by this practice does not imply validation and calibration under all combinations of test foot materials and walkway surfaces.5.3.4 The validation and calibration procedure defined by this practice is not intended to establish a “safe threshold” value for any walkway surface.1.1 This practice is intended to establish the procedures for validation, calibration, and certification of walkway tribometers.1.2 This practice provides a walkway tribometer supplier with a procedure and suite of reference surfaces to validate his walkway tribometer by properly ranking and differentiating the surfaces.1.3 This practice provides the user of a walkway tribometer with a procedure and suite of reference surfaces to test calibration of his instrument.1.4 This practice provides a procedure through which an entity may certify a walkway tribometer model, signifying that the walkway tribometer model has a completed and documented validation and interlaboratory study.1.5 This practice describes the necessary materials, specifications, and the cleaning process for reference materials, as well as the requirements for the validation of a supplier’s walkway tribometer and calibration of a user’s walkway tribometer.1.6 This practice applies to walkway tribometers without reference to the nature of the scale of the readings produced by them. The scale used in the reports of validation and calibration must be the same, and are to be those of the instrument or defined for the instrument.1.7 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only and are not considered standard.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health and environmental practices and determine the applicability of regulatory limitations prior to use.1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

4.1 A waterproofing membrane should maintain its watertight integrity for the life of the building in a continuously or intermittently moist environment and may be subject to continuous or intermittent hydrostatic pressure. It should resist chemicals that can harm the membrane and root growth. This guide lists minimum performance attributes required of waterproofing membranes applied to below-grade walls. Products not previously used as waterproofing membrane materials require additional tests beyond the scope of this guide. This guide is not intended for use on in-service waterproofing materials. Waterproofing membranes and other components should conform to ASTM product standards, if available.4.2 Limitations—Prior to use and in service, waterproofing may be exposed to a variety of conditions so no one test will provide evaluations related to performance for all exposures. Neither will all tests be necessary in all evaluations for specific exposures.1.1 This guide lists test methods intended to establish a minimum level of acceptable performance attributes for reinforced or laminated waterproofing membranes applied to below-grade walls.1.2 This guide does not include cementitious, integral, or bentonite waterproofing systems.1.3 This guide does not include membranes applied under slabs on grade or on suspended slabs below grade or applied to soil retaining systems, water containment structures, or tunnels.1.4 It is not possible to establish a precise correlation between laboratory tests on waterproofing membranes and performance attributes after installation due to variations in chemicals in the soil, design, material, and installation.1.5 The values stated in either inch-pound or SI units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
154 条记录,每页 15 条,当前第 1 / 11 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页