【国外标准】 Standard Guide for Assessing the Removal of Additive Manufacturing Residues in Medical Devices Fabricated by Powder Bed Fusion
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>
标准简介
适用范围:
5.1 Materials used in medical devices are selected in part for their biocompatibility, meaning that they have been demonstrated to have an acceptable biological response for the intended application. During manufacturing, most devices are exposed to a variety of processing steps and materials that have the potential to adversely affect the inherent biocompatibility of the device if they are not adequately removed prior to use.NOTE 1: For a fine powder, depending upon application, a new biological risk assessment may be required.5.2 In additive manufacturing, components are in most cases built layer-by-layer, allowing unprecedented freedom to design complex devices. This makes it possible to build devices that are very difficult to clean, such as topological optimized parts, small internal channels, lattice structures, and especially reticulated porous structures for bone ingrowth and fixation.5.3 Powdered fusion AM presents additional challenges. Components come out of the build volume with residual powder filling all open spaces within the device. The majority of the excess powder is typically removed by a combination of vibratory shaking, blowing with compressed gas, vacuuming, and ultrasonic cleaning in a solvent. However, the particles are typically very small and can become lodged in internal features such as pores, making removal difficult. Furthermore, particles that were immediately adjacent to the component during manufacturing can be partially sintered to the surface. Those particles can be extremely difficult to remove, are indistinguishable from loose particles when observed by most techniques, and may be at risk of detaching during the intended use of the device.5.4 This guide provides specific evaluation techniques for measuring the effectiveness of residue removal processes, as they should be able to yield consistent results that meet the respective performance and cleanliness criteria for the intended use.1.1 This standard provides guidance for assessing the manufacturing material residues in medical devices fabricated using additive manufacturing (AM) techniques, specifically, from powder bed fusion AM technologies.1.1.1 Some of the techniques discussed in this guide may be applicable to devices fabricated by other types of AM equipment (e.g., stereolithography). Given each AM technique’s characteristics and post-processing challenges, there could be additional risks or considerations associated with some AM techniques or materials that are not addressed by this guide.1.2 This guide covers several qualitative and quantitative assessments of the presence and amount of residue remaining in or obtained by extraction in aqueous or organic solvents from powder bed fusion AM medical components.1.2.1 This guide identifies techniques to qualitatively determine the presence of residue and a technique to quantitatively assess it. It does not set acceptance criteria or acceptable limits for residues remaining in built parts. These methods are not the only methods to determine the presence or quantity of residual material in additive manufactured medical components.1.3 This guide pertains to devices in their finished state (after post-processing and subsequent manufacturing processes), as applicable. This guide may also be used to evaluate the effectiveness of cleaning processes between critical steps in the manufacturing process, to ensure minimal AM residue remains for cleaning processes downstream.1.4 This guide is not intended to evaluate the residue level in medical components that have been cleaned for reuse.1.5 Different cleaning methods, including high energy processes, can potentially damage small structures in AM parts. This guide does not address measurement or mitigation of this risk.1.6 This guide does not address the manufacturing occupational health issues of working with small particles (e.g., breathing hazards).1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM F3335-20
标准名称:
Standard Guide for Assessing the Removal of Additive Manufacturing Residues in Medical Devices Fabricated by Powder Bed Fusion
英文名称:
Standard Guide for Assessing the Removal of Additive Manufacturing Residues in Medical Devices Fabricated by Powder Bed Fusion标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- 国家标准计划
- BS ISO 24138:2024 Information and documentation. International Standard Content Code (ISCC)
- 24/30492859 DC BS EN IEC 61753-1 Fibre optic interconnecting devices and passive components - Performance standard
- BS EN IEC 61753-071-02:2020+A1:2024 Fibre optic interconnecting devices and passive components. Performance standard
- 24/30491443 DC standard
- 24/30489392 DC BS EN IEC 62358 Ferrite cores. Standard inductance factor for gapped cores and its tolerance
- BS ISO 19848:2024 - TC Tracked Changes. Ships and marine technology. Standard data for shipboard machinery and equipment
- BS ISO 19848:2024 Ships and marine technology. Standard data for shipboard machinery and equipment
- BS IEC 61360-7:2024 Standard data element types with associated classification scheme
- 24/30487130 DC BS EN 50566:2017/A2:2024 Product standard to demonstrate the compliance of wireless communication
- 24/30486472 DC - Product standard
- KS M ISO 4259-4 석유 및 관련 제품 — 측정 방법과 결과의 정밀도 — 제4부: 개별 실험실에서 표준 시험방법의 실행에 대한 ‘통계적 관리’ 상태를 확인하기 위한 통계적 관리도의 사용
- KS C IEC 61340-4-6 정전기학 — 제4-6부: 구체적 적용 분야에 대한 표준 시험방법 — 손목접지대
- KS C IEC 61340-4-7 정전기학 — 제4-7부: 구체적 적용 분야에 대한 표준 시험방법 — 이온화
- KS C IEC 61340-4-8 정전기학 — 제4-8부: 구체적 적용 분야에 대한 표준 시험방법 — ESD 차폐성 — 봉투
- 24/30485973 DC standard