
【国外标准】 Standard Practices for Sampling Electrical Insulating Liquids
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 Accurate sampling, whether of the complete contents or only parts thereof, is extremely important from the standpoint of evaluating the quality of the liquid insulant sampled. Obviously, examination of a test specimen that, because of careless sampling procedure or contamination in sampling equipment, is not directly representative, leads to erroneous conclusions concerning quality and in addition results in a loss of time, effort, and expense in securing, transporting, and testing the sample.4.2 A study of gases and moisture contained in insulating oils from transformers and other electrical power apparatus can frequently give an early indication of abnormal behavior of the apparatus, and may indicate appropriate action be taken on the equipment before it suffers greater damage. Specific gas and moisture content can be determined from oil sampled for this purpose.1.1 These practices cover sampling of new electrical insulating liquids including oils, askarels, silicones, synthetic liquids, and natural ester insulating liquids as well as those insulating liquids in service or subsequent to service in cables, transformers, circuit breakers, and other electrical apparatus. These practices apply to liquids having a viscosity of less than 6.476 × 10-4 m2/s (540 cSt) at 40 °C (104 °F).1.2 Representative samples of electrical insulating liquids are taken for test specimens so that the quality pertinent to their use may be determined. The quality in different portions of a given container, or the average quality of the whole bulk may be ascertained if desired.1.3 The values stated in SI units are regarded as the standard where applicable. Inch pound units are used where there is no SI equivalent.1.4 These practices also include special techniques and devices for sampling for dissolved gases-in-oil (DGA) (D3612), water (D1533) and particles (D6786).1.5 For ease of use, this document has been indexed as follows:Section Title Section/Paragraph Mandatory Conditions and General Information Section 5Description of Sampling Devices and Containers Section 6, Annex A1, Appendix X2Most Frequently Used Sampling Techniques for Electrical Apparatus Collecting Samples from Electrical Equipment Using Bottles and Cans Section 7, Appendix X1, Appendix X2Collecting Samples from Electrical Equipment Using Glass Syringes (DGA and Water Analysis) Section 8Collecting Samples from Electrical Equipment Using Stainless Steel Cylinders (DGA and Water Analysis) Section 9 Sampling of Cans, Drums, Tank Cars, Tank Trucks and Small Electrical Equipment Sampling Using the Dip-Type Device (drum thief) Section 10Sampling Using the Pressure-Type Device Section 11, Annex A1.1Sampling Using the Tank Car-Type Device Section 12, Annex A1.2Sampling Cable Feeders Mandatory Conditions Section 13 General Considerations Section 14 Sampling Using the Manifold-Type Device Section 15, Annex A1.3Cleaning, Preparation, Storage, and Handling of Sampling Containers Section 16Storage, Packaging and Shipping of Samples Section 17Cleaning and Storage of Sampling Devices Section 18Sample Information Section 19 Mandatory Information—Construction of Sampling Devices Annex A1Determination of Electrical Apparatus Temperature Appendix X1Sample Container Types Appendix X21.6 Handle askarels containing polychlorinated biphenyls (PCBs) according to federal and local regulations existing for that country. For example, the federal regulations concerning PCBs in the United States can be found in 40 CFR Part 761.1.7 Properly contain, package and dispose of any liquid or material resulting from the use of these practices in a manner that is in accordance with local and state regulations specific to the country in which the samples are taken.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific warning statements are given in 1.6, 1.7, Section 5, 10.1, 13.2, 15.2.3, Section 16, and 18.2. These practices involve close contact with the electrical insulating liquids being sampled as well as liquids and other materials used to clean the sampling tools and devices. When required, or as a matter of diligence to personal safety, use personal protective equipment (PPE).1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D923-15(2023)
标准名称:
Standard Practices for Sampling Electrical Insulating Liquids
英文名称:
Standard Practices for Sampling Electrical Insulating Liquids标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E1160-13(2021) Standard Guide for On-Site Inspection and Verification of Operation of Solar Domestic Hot Water Systems
- ASTM E1162-11(2019) Standard Practice for Reporting Sputter Depth Profile Data in Secondary Ion Mass Spectrometry (SIMS)
- ASTM E1164-23 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation
- ASTM E1173-23 Standard Practice for Evaluation of Preoperative, Precatheterization, or Preinjection Skin Preparations
- ASTM E1174-21 Standard Test Method for Evaluation of the Effectiveness of Healthcare Personnel Handwash Formulations
- ASTM E1179-13(2019) Standard Specification for Sound Sources Used for Testing Open Office Components and Systems
- ASTM E1180-08(2021) Standard Practice for Preparing Sulfur Prints for Macrostructural Evaluation
- ASTM E1198-19 Standard Practice for Sampling Zooplankton with Pumps
- ASTM E1199-19 Standard Practice for Sampling Zooplankton with a Clarke-Bumpus Plankton Sampler
- ASTM E1208-21 Standard Practice for Fluorescent Liquid Penetrant Testing Using the Lipophilic Post-Emulsification Process
- ASTM E1211/E1211M-17 Standard Practice for Leak Detection and Location Using Surface-Mounted Acoustic Emission Sensors
- ASTM E1213-14(2022) Standard Practice for Minimum Resolvable Temperature Difference for Thermal Imaging Systems
- ASTM E1218-21 Standard Guide for Conducting Static Toxicity Tests with Microalgae
- ASTM E1219-21 Standard Practice for Fluorescent Liquid Penetrant Testing Using the Solvent-Removable Process
- ASTM E122-17(2022) Standard Practice for Calculating Sample Size to Estimate, With Specified Precision, the Average for a Characteristic of a Lot or Process