微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

3.1 These test methods are used to evaluate the properties of self-adhesive modified bituminous membranes. The results determine compliance with the applicable specifications, or they can be used for comparative analysis.3.2 The test methods apply to “as manufactured” material and may not apply to material that has been weathered or is past the manufacturer’s recommended shelf life.1.1 These test methods cover test procedures for prefabricated, reinforced, self-adhesive (SA) polymer-modified bituminous sheet materials designed for single- or multiple-ply application in roofing and waterproofing membranes.1.2 These test methods specifically address the self-adhesive characteristics of modified bituminous sheet materials, and are intended as a supplement to those found in Test Methods D5147/D5147M.1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.4 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This specification covers prefabricated asphalt liner sheets intended for installation to provide a continuous, exposed lining for reservoirs, ponds, canals, and ditches. The liner sheets shall consist of layers of asphalt mastic between asphalt-saturated felts, mats, or fabrics, and shall be coated on both sides and covered with a material to prevent the finished sheets from sticking together during storage and shipment. The coating shall be a hot-applied asphalt material permitted to be compounded with a mineral stabilizer. Thickness of asphalt coating, water absorption, mass percent of asphalt, resistance to decay, flexibility, brittleness, and heat dissipation tests shall be performed to conform to the requirements specified.1.1 This specification covers prefabricated bituminous geomembranes intended to provide a continuous, exposed lining for canals and ditches.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers bituminous preformed expansion joint filler for use in concrete construction. This product shall consist of a bituminous (asphalt or tar) mastic composition, formed and encased between two layers of bituminous impregnated felt or two layers of glass-fiber felt. The mastic shall comprise mineral fillers and reinforcing fibers and may contain thin strips of reinforcing sheet material. Different test methods shall be performed in order to determine the following properties: distortion at 52°C, brittleness, water absorption, and compression.1.1 This specification covers bituminous preformed expansion joint filler for use in concrete construction.NOTE 1: Attention is called to ASTM Specifications D1751 and D1752.1.2 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

The specimens are compacted to simulate the density, aggregate degradation, and structural characteristics possible in the actual road surface when proper construction procedure is used in the placement of the material. The specimens may be used to determine stability, density, strength, water susceptibility, etc., of bituminous mixtures by specified test methods.1.1 This practice covers the preparation of 4-in. (101.6 mm) diameter test specimens of bituminous mixtures containing −7/8-in. (–22.4-mm) aggregate.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

This practice covers the performance requirements for the design, components, construction, and service expectations of new roof system assemblies that always include steel deck, preformed roof insulation, and bituminous built-up roofing, and their attachment. It may also include fire-resistive components, integral acoustical treatment, vapor retarder, adhesive or mechanical fastener attachment, and aggregates.1.1 This practice covers the performance requirements for the design, components, construction, and service expectations of new roof system assemblies. For this purpose, the roof system always includes steel deck, preformed roof insulation, and bituminous built-up roofing, and their attachment. It may also include fire-resistive components, integral acoustical treatment, vapor retarder, adhesive or mechanical fastener attachment, and aggregates.1.2 The objective is to provide realistic criteria for the overall performance of the roof assembly and its components because by necessity and custom, a roof assembly contains a variety of components and is subject to varied environmental conditions.1.3 To assist in the successful implementation of the installation and service requirements of the roof system assembly, criteria are established to provide for compatibility of the various components.1.4 Nothing in this practice is intended to exclude products or systems not covered by the documents referenced in Section 2.1.5 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

This specification covers the standards for polymer modified bituminous sheet materials proposed for use as underlayment on roof eaves, or valleys, or both, to prevent leakage of shingle, tile or metal roofs from water back-up due to ice dams. The underlayment sheet shall comply with the physical requirements which include thickness, maximum load, elongation, adhesion to plywood, thermal stability, flexibility, tear resistance, moisture vapor permeance, sealability, and slip resistance. The underlayment sheet shall not crack, as well, nor be too sticky as to cause damage upon being unrolled.1.1 This specification covers polymer modified bituminous sheet materials intended for use as underlayment on roof eaves, or valleys, or both, to prevent leakage of shingle, tile, or metal roofs from water back-up due to ice dams.1.2 These underlayment sheets have a sticky adhesive layer which is exposed by removal of a protective sheet. The top surface is suitable to work on during the application of the exposed roofing.1.3 Table of Contents:   Section 1Referenced Documents 2Terminology 3Workmanship, Finish, and Appearance 4Physical Requirements 5Sampling 6Test Methods 7     Conditioning 7.1     Thickness 7.2     Maximum Load and Elongation at Break 7.3     Adhesion to Plywood 7.4     Thermal Stability 7.5     Flexibility at –29 °C [–20 °F] 7.6     Tear Resistance 7.7     Moisture Vapor Permeability 7.8     Capability to Seal Around Nail         (Head of Water Test) 7.9     Waterproof Integrity of Side Lap Seam         (Head of Water Test) 7.10Inspection 8Rejection and Rehearing 9Packaging and Package Marking 10Keywords 111.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This specification covers prefabricated bituminous sheet materials reinforced with a combination of polyester fabric and glass fiber, with or without granules, modified by styrene butadiene styrene (SBS) thermoplastic elastomer, and are intended for use in the fabrication of multiple ply roofing and waterproofing membranes. This specification is intended as a material specification only. Hence, issues regarding the suitability of the specific roof constructions or application techniques are beyond this scope. Also not addressed here are in-place roof system design criteria such as fire resistance, field strength, impact/puncture resistance, material compatibility, uplift resistance, and others. Materials shall conform to specified values of the following dimensional and physical properties: total and bottom coating thickness; net mass per unit area; peak load before and after heat conditioning; elongation at peak load; ultimate elongation; tear strength; low temperature flexibility; dimensional stability; compound stability; and granule embedment.1.1 This specification covers prefabricated modified bituminous sheet materials reinforced with a combination of polyester fabric and glass fiber, with or without granules, which use styrene butadiene styrene (SBS) thermoplastic elastomer as the primary modifier and are intended for use in the fabrication of multiple ply roofing and waterproofing membranes.1.2 This specification is intended as a material specification only. Issues regarding the suitability of the specific roof constructions or application techniques are beyond this scope.1.3 The specified tests and property limits used to characterize the sheet materials are intended to establish minimum properties. In-place roof system design criteria such as fire resistance, field strength, impact/puncture resistance, material compatibility, uplift resistance, and others, are factors beyond the scope of this material specification.1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 This test method provides a means of evaluating roofing systems for resistance to impact loads of many kinds. It should also be useful in developing performance criteria for roofing systems.1.1 This test method covers the determination of the resistance of bituminous roofing systems to impact loads at any desired temperature, with a missile of the weight, size, and shape specified herein.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers Grades G (granule surfaced) and S (smooth surfaced) prefabricated bituminous sheet materials with glass fiber reinforcement that has been modified by styrene butadiene styrene (SBS) thermoplastic elastomer, and are intended for use in the fabrication of multiple ply roofing and waterproofing membranes. This specification is intended as a material specification only, and does not address issues regarding the suitability of the specific roof constructions or application techniques. The specified tests and property limits used to characterize the sheet materials are intended to establish minimum properties, Hence, roof system design criteria such as fire resistance, field strength, impact/puncture resistance, material compatibility, uplift resistance, and others are factors beyond its scope. Material properties for which the sheet materials should adhere to are peak load before and after heat conditioning, elongation at peak load, ultimate elongation, tear strength, low temperature flexibility, dimensional stability, compound stability at specified temperatures, and granule embedment.1.1 This specification covers prefabricated modified bituminous sheet materials with glass fiber reinforcement, with or without granules, that use styrene butadiene styrene (SBS) thermoplastic elastomer as the primary modifier and are intended for use in the fabrication of multiple ply roofing and waterproofing membranes.1.2 This specification is intended as a material specification only. Issues regarding the suitability of the specific roof constructions or application techniques are beyond this scope.1.3 The specified tests and property limits used to characterize the sheet materials are intended to establish minimum properties. In-place roof system design criteria, such as fire resistance, field strength, impact/puncture resistance, material compatibility, uplift resistance, and others, are factors beyond the scope of this material specification.1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers Grades G (granule surfaced) and S (smooth surfaced) prefabricated bituminous sheet materials reinforced with polyester fabric and modified by styrene butadiene styrene (SBS) thermoplastic elastomer, intended for use in the fabrication of multiple ply roofing and waterproofing membranes. The sheet materials shall meet dimensional requirements such as thickness and net mass per unit area, as well as physical requirements such as peak load before and after heat conditioning, elongation at peak load, ultimate elongation, tear strength, low temperature flexibility, dimensional stability, compound stability, and granule embedment.1.1 This specification covers prefabricated modified bituminous sheet materials reinforced with polyester fabric as the primary reinforcement (see Note 1), with or without granules, which use styrene butadiene styrene (SBS) thermoplastic elastomer as the primary modifier and are intended for use in the fabrication of multiple ply roofing and waterproofing membranes.NOTE 1: Many modified bituminous sheets are currently marketed with polyester mat reinforced with glass yarns to improve processing in the manufacture of the finished modified bitumen product and to reduce distortions that may be introduced during production. These glass yarns are typically a small percentage of the reinforcement and do not contribute to the physical properties of the finished product so much as to make these products be classified by Specification D6162/D6162M.1.2 This specification is intended as a material specification only. Issues regarding the suitability of the specific roof constructions or application techniques are beyond this scope.1.3 The specified tests and property limits used to characterize the sheet materials are intended to establish minimum properties. In-place roof system design criteria, such as fire resistance, field strength, impact/puncture resistance, material compatibility, uplift resistance, and others, are factors beyond the scope of this material specification.1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This practice provides a standard by which organizations can provide a uniform quality service in producing and applying bituminous paving materials in construction. The practice outlines and describes the procedures for establishing and maintaining a quality control system.The control of quality is a continuing process; consequently, this practice provides not only for the formation of a program but for its continuation through calibration, standardization, and reference sample and inspection programs.The basic requirements for a quality control system encompass the following, all of which shall be documented:3.3.1 Quality policy, planning, and administration,3.3.2 Organization,3.3.3 Human resources,3.3.4 Physical resources, and3.3.5 Quality control and evaluation.1.1 This practice prescribes the general requirements for the establishment and maintenance of a quality control system for organizations producing or applying bituminous paving materials, or both, in construction.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

5.1 This test method is useful in characterizing certain bituminous materials, as one element in establishing uniformity of shipments and sources of supply.5.2 This test method is an extension of Test Method D88/D88M.1.1 This test method covers the empirical procedures for determining the Saybolt Furol viscosities of bituminous materials at specified temperatures between 120 and 240 °C [248 and 464 °F].1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See 8.1.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This test method is useful as an indicator of the susceptibility to moisture of compacted bitumen-aggregate mixtures. Note 1—The quality of the results produced by this standard are dependent on the competence of the personnel performing the procedure and the capability, calibration, and maintenance of the equipment used. Agencies that meet the criteria of Standard Practice are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this standard are cautioned that compliance with alone does not completely assure reliable results. Reliable results depend on many factors; following the suggestions of or some similar acceptable guideline provides a means of evaluating and controlling some of those factors.1.1 This test method covers measurement of the loss of compressive strength resulting from the action of water on compacted bituminous mixtures containing asphalt cement. A numerical index of reduced compressive strength is obtained by comparing the compressive strength of freshly molded and cured specimens with the compressive strength of duplicate specimens that have been immersed in water under prescribed conditions. 1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

4.1 This practice provides general procedures, information, guidelines, and precautions for the application of heat welded modified bituminous waterproofing systems used as part of a new horizontal waterproofing system.4.2 This practice is not all-inclusive and is intended only to supplement detailed instructions from designers and system manufacturers.4.3 The horizontal (low sloped) deck or substrate referred to in this practice is reinforced cast-in-place structural concrete.1.1 This practice covers the minimum application recommendations for heat weldable atactic polypropylene (APP) modified bituminous systems used as part of a new horizontal waterproofing system over occupied spaces of buildings where covered by a separate wearing course.1.2 For the purpose of this practice, the substrate shall be structurally sound, sloped to drain, able to accept the weight of the membrane and other system materials, and meet the local building code requirements. Similarly, all components of the waterproofing system are assumed to comply with any federal, state, and local environmental regulations that may be in effect at the time of installation. Expansion joints, insulation, drainage layers, protection boards, filter sheets, and the wearing surfaces are beyond the scope of this practice.1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

定价: 0元 / 折扣价: 0

在线阅读 收 藏
65 条记录,每页 15 条,当前第 4 / 5 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页