微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 78元 / 折扣价: 67 加购物车

在线阅读 收 藏
HB 18.60-2005 (R2016) Conformity assessment - Code of good practice 现行 发布日期 :  2005-11-21 实施日期 : 

定价: 260元 / 折扣价: 221

在线阅读 收 藏

This practice covers preparation of iron castings for electroplating and is intended to assist electroplaters in establishing and maintaining a satisfactory pre-electroplating cycle for malleable iron, gray iron, nodular iron, and white iron castings. It is also intended to indicate certain foundry practices which will facilitate subsequent finishing. The seacoal content of the molding and facing sands should be maintained at the maximum practicable limits to minimize the occlusion of sand in the surfaces of the castings. The steps for the preparation of ferrous castings for electroplating are presented. The various solutions used for the treatment of malleable and gray iron castings should be maintained by chemical analysis so far as is practicable. When the amount of soil is excessive, particularly where no precleaning is done, it may be desirable to double the cleaning and pickling facilities. Where doubling the facilities is impossible or impracticable, similar economies may be obtained to a degree by providing cleaner and pickle tanks with overflow dams, sumps and pumps with which the solution may be recirculated. In electrified tanks removable electrodes should be employed in preference to using the tank as an electrode, to facilitate inspection and cleaning. All immersion rinse tanks should be equipped with dam-type overflows to ensure skimming of oil, grease, and light dirt from the surface of the water. The paper presents the cleaning procedure cycle generally used for racked parts which will subsequently electroplated in still tanks, semiautomatic equipment, and full-automatic equipment. The most reliable test of the effectiveness of the preplating cleaning cycle is the appearance of the electroplated part and its performance in service.1.1 This practice is intended to assist electroplaters in establishing and maintaining a satisfactory pre-electroplating cycle for malleable iron, gray iron, nodular iron, and white iron castings. It is also intended to indicate certain foundry practices which will facilitate subsequent finishing. Most of the practices that follow have been based on experience with malleable and gray iron. However, since they are related to the other forms, the same practices will probably apply. Nodular iron is also known as spheroidal or ductile iron, which is defined as cast iron with the graphite substantially in spherical shape and substantially free of flake graphite.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 2.1.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 481元 / 折扣价: 409 加购物车

在线阅读 收 藏
ASTM F269-60(2019) Standard Test Method for Sag of Tungsten Wire Active 发布日期 :  1970-01-01 实施日期 : 

This test method covers a determination of the sag properties of tungsten wire. The specimen of tungsten wire to be tested for sag shall have a clean, bright surface and should have the required length. With the aid of external heat, the test specimen shall be bent into a hairpin-shape until it reached the required distance between the ends. The formed test specimen shall be of sufficient length so that when clamped in the fixture, the exposed lengths measured from the top of the apex will be of required distance.1.1 This test method covers a determination of the sag properties of tungsten wire 0.030 in. (0.76 mm) and over in diameter.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 689元 / 折扣价: 586 加购物车

在线阅读 收 藏
ASTM D1542-60(1993)e1 Test Method for Qualitative Detection of Rosin in Varnishes (Withdrawn 1997) Withdrawn, No replacement 发布日期 :  1970-01-01 实施日期 : 

1.1 This test method covers procedures for the qualitative detection of rosin in varnishes by the Lieberman-Storch Test, and the Halphen-Hicks Test. The rosin may be present as either free rosin (abietic acid), esterified rosin, or as metal salts.1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.>

定价: 0元 / 折扣价: 0

在线阅读 收 藏

定价: 605元 / 折扣价: 515

在线阅读 收 藏

定价: 605元 / 折扣价: 515

在线阅读 收 藏

1.1 These test methods cover the determination of glycerol, ethylene glycol, and pentaerythritol in alkyd resins and resin solutions. Other polyhydric alcohols that can be oxidized by periodic acid to formaldehyde or formic acid, or both, will interfere with the determination of glycerol and ethylene glycol (see Test Methods D2456 or D2998). Urea, melamine, or phenolic resins interfere and render this procedure inapplicable. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

定价: 481元 / 折扣价: 409

在线阅读 收 藏
39 条记录,每页 15 条,当前第 1 / 3 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页